Double Door
Item No.
Project
Quantity
MODEL: LRP2S Series
Construction Features
Heavy duty stainless steel exterior with 300 Series
stainless steel interior and aluminized steel top
Walls Ceilings and doors are foam insulated
Modular wall and ceiling panels with cam lock construction
Rapid responding air-wash heat and humidity system
208/120 VAC single or 3-phase power, field convertible
Performance Features
70 - 120 Degree F proofing range
Non-submerged calrod type heaters
Interior bumpers protect interior walls from damage
All digital controls mounted in the door at eye-level
PID Type controls for rapid accurate response without overshoot
Digital set Temperature, Humidity, Time
Installed in the left hand door at eye-level
5 Timers for multiple products
all 300 series stainless steel interior, with protective cart bumpers; heavy-
eye-level, with accurate digital temperature, humidity and time readouts;
Sheet Number LRP2S v 1 (rev 1/13)
Roll-In Proofer
Construction Features
♦ Heavy duty stainless steel exterior with
300 Series stainless steel interior and
aluminized steel top
♦ Walls Ceilings and doors are foam insulated
♦ Modular wall and ceiling panels with cam
lock construction
♦ Rapid responding air-wash heat and
humidity system
♦ 208/240 VAC single or 3-phase power, eld
convertible
Performance Features
♦ 70 - 120 Degree F proong range
♦ 50 - 99% humidity range
♦ Non-submerged calrod type heaters
♦ Interior bumpers protect interior walls from
damage
♦ Lighted interior
Controls Features
♦ All digital controls mounted in the door at
eye-level
♦ PID Type controls for rapid accurate
response without overshoot
♦ Digital set Temperature, Humidity, Time
♦ Installed in the left hand door at eye-level
♦ Large LED displays
♦ 5 Timers for multiple products
LRP-2S Series
Model LRP2S-40 Shown (rack not included)
MODEL / RACK CAPACITY
Model / Depth Side Load End Load Double
LRP2S-30
LRP2S-40
LRP2S-50
LRP2S-60
LRP2S-70
LRP2S-80
LRP2S-90
LRP2S-100
LRP2S-110
LRP2S-120
Short Bid Specification:
Proofer shall be an LBC Bakery Equipment Model LRP2S-
30,40,50,60,70,80, 90,100, 110, 120] 5 to 13.2 kW electrically heated,
double door roll-in rack unit with: quick responding air-wash heat /
humidity system; modular foam insulated cam lock panel construction;
2 Racks 3 Racks None
4 Racks 3 Racks 2 Racks
4 Racks 3 Racks 2 Racks
6 Racks 6 Racks 2 Racks
6 Racks 6 Racks 2 Racks
9 Racks 6 Racks 4 Racks
9 Racks 9 Racks 4 Racks
10 Racks 9 Racks 4 Racks
10 racks 12 Racks 4 Racks
12 Racks 12 Racks 6 Racks
[insert
1C Enterprise Place, Hicksville, NY 11801-5356 Ph: (516) 681-1500 Fx: (516) 681-1510
1-800-878-4070 www.empirebake.com Email: info@empirebake.com
duty door with magnetic seal/mechanical closure system and full width
protective bar handle; simple computerized controls, door mounted at
plus all the features listed and options checked.

Technical Data
LRP2S-0414
Ships KD requires on-site installation
240/120 VAC 1 or 3-phase
Model
LRP2S-30
LRP2S-40
LRP2S-50
LRP2S-60
LRP2S-70
LRP2S-80
LRP2S-90
LRP2S-100
LRP2S-110
LRP2S-120
Model Voltage 1-Ph 3-Ph 1-Ph 3-Ph
LRP2- (40-80)
LRP2- (90-120)
208 VAC 30 18 50 50
240 VAC 34 20 50 50
208 VAC NA 35 NA 60
240 VAC NA 39 NA 60
Internal "A"
26.1
36.1
46.1
56.1
66.1
76.1
86.1
96.1
106.1
116.1
Total Electrical Requirements By Model
Total kW
5
6.6
10.2
13.2
1/2" NPT Cold water conection
3/4" Copper vented drain connection
Stainless Steel Floors Correctional Pack
Ext. "B"
31.1
41.1
51.1
61.1
71.1
81.1
91.1
101.1
111.1
121.1
*MCA *Max Fuse
Over All "C"
39.3
49.3
59.3
69.3
79.3
89.3
99.3
109.3
119.3
129.3
Width
75.5 1100 1200
75.5 1157 1282
75.5 1329 1454
75.5 1411 1536
75.5 1493 1618
75.5 1665 1790
75.5 1924 2049
75.5 2006 2131
75.5 2178 2303
75.5 2260 2385
1/2" NPT .07
GPM @ 60 PSI
1/2" NPT .14
GPM @ 60 PSI
Actual Ship
Water
1/2"PVC; 210 F;
<1 GPM Max.
1/2"PVC; 210 F;
<1 GPM Max.
Freight
Class
85
Drain
This Appliance is designed to operate at normal room temperatures; Clearance from combustibles is
IMPORTANT: Your local water conditions may damage your LBC appliance. Failure to properly treat water may
result in damage and may void your warranty. Ensure that your water supply meets these minimum water quality
Parameter Parameter
Alkalinity
Aluminium
Calsium
Free Chlorine Residual
0.0" sides and back, For Install on non-porous surfaces only
*MCA: Minimum Circuit Ampacity. *Max Fuse: Maximum allowable circuit protector.
specification.
ppm 22 ppm 0.65
ppb 17 s.u. 8.5
ppm 3.3 ppm 8.5
ppm 0.6 ppm 11.9
Magnesium
pH
Sodium
Total Hardness
1C Enterprise Place, Hicksville, NY 11801-5356 Ph: (516) 681-1500 Fx: (516) 681-1510