EMP-Centauri MS17/4PIU-6, MS17/6PIU-6, MS17/8PIU-6, MS17/12PIU-6, MS17/16PIU-6 User guide

...
12 EMP-Centauri's PROFI CLASS Related Products
1 of 8
8 of 8
Instruction Manual 1/003021 E
MS17/4PIU-6 V10 MS17/6PIU-6 V10 MS17/8PIU-6 V10
Dear Customer, congratulations on the purchase of the EMP-Centauri product. Before its installation and putting into operation, read carefully the entire operation manual. Keep the purchase and rework (if any) records for future need.
MS17/12PIU-6 V10 MS17/16PIU-6 V10 MS17/20PIU-6 V10
MS17/26PIU-6 V10
Content
1 Field of Application, Warranty 1 2 Technical Specifications 1 3 Product Takeover 3 4 Product Storing and Installations 3 5 Product Connection 4 6 Product Settings 4 7 Safety 6 8 Product Maintenance 6 9 Troubleshooting 6 10 Symbols Explanation 7 11 Wiring Diagrams 8 12 EMP-Centauri Related Products 8 13 Contact 8
13 Contact
EMP-Centauri s.r.o.
5. kvetna 690 339 01 Klatovy 4 Czech Republic
tel: (+420) 376 314 852 fax: (+420) 376 314 367 info@emp-centauri.cz www.emp-centauri.eu
1 Field of Application, Warranty
The product is designed for the distribution of satellite (SAT), terrestrial (TERR); TV and radio signals. We recommend the device to be installed and serviced by the qualified technician. EMP-Centauri's PROFI CLASS products are covered under 4 (four) years warranty from the date of purchase. The warranty shall not apply to the product used for other than the specified purpose. The user will be responsible for injury or material damage which may arise in consequence of any product use in contradiction with the manual. It is prohibited to dismantle the product and make any interventions in it. Repairs or any interventions in the product may be performed only by EMP-Centauri company, or other companies authorized by EMP-Centauri.
The products are standalone multiswitches for distribution of terrestrial and satellite signals from 4 satellite positions (16 polarities) to 4 (MS17/4PIU-6), 6 (MS17/6PIU-6), 8 (MS17/8PIU-6), 12 (MS17/12PIU-6), 16 (MS17/16PIU-6), 20 (MS17/20PIU-6) or 26 (MS17/26PIU-6) users. Multiswitches are controlled by DiSEqC 2.0 commands from a satellite receiver. It is enabled to switch on active or passive mode of terrestrial band. Multiswitches are compatible with quad LNB, it is possible to switch on or off signal 22 kHz at satellite inputs of hight band. Terrestrial input can supply terrestrial antenna preamplifier with DC voltage, the supply is electronically protected against short-circuit. Multiswitches are powered from internal power supply P3U27.
Specification
7 of 8
2 of 8
MS17/4PIU-6
V10
MS17/6PIU-6
V10
MS17/8PIU-6
V10
MS17/12PIU-6
V10
Number of Inputs 17
Number of Outputs 4 6 8 12
Frequency Range TERR 5-862 MHz (pas), 40-862 MHz (act), SAT 950-2300 MHz
Insertion Loss (avg)
TERR 0/12dB (act /pas), SAT 0 dB
TERR 0/14dB (act/ pas), SAT 0 dB
TERR 2/16dB (act/ pas), SAT 0 dB
TERR 5/19dB (act/pas), SAT 0 dB
Isolation (min) 20 dB
Maximum Input level*
Maximum Output Level*
TERR 90/110 dBuV (act/pas), SAT 90 dBuV
TERR 90/98 dBuV (act/pas), SAT 90 dBuV
TERR 90/96 dBuV (act/pas), SAT 90 dBuV
TERR 88/94 dBuV (act/pas), SAT 90 dBuV
TERR 85/91 dBuV (act/pas), SAT 90 dBuV
Control DiSEqC 2.0
Current Consumption
80 mA (18 V DC) from each satellite receiver
Terr. Input Current 150 mA max (12 V DC)
Power Consumption
7.0 W / 5.0 W (act/pas) + consumption of devices connected to inputs
Dimensions (w,d,h) 47.0 x 15.2 x 8.7 cm (including power supply)
Temperature Range -30°C - +70°C
Specification MS17/16PIU-6
V10
MS17/20PIU-6
V10
MS17/26PIU-6
V10
Number of Inputs 17
Number of Outputs 16 20 26
Frequency Range TERR 5-862 MHz (pas), 40-862 MHz (act), SAT 950-2300 MHz
Insertion Loss (avg)
TERR 7/21dB (act /pas), SAT 0 dB
TERR 9/24 dB (act /pas), SAT 4 dB
TERR 10/25 dB (act/pas), SAT 5 dB
Isolation (min) 20 dB
Maximum Input level*
Maximum Output Level*
TERR 90/110 dBuV (act/pas), SAT 90 dBuV
TERR 83/89 dBuV (act/pas), SAT 90 dBuV
TERR 81/86 dBuV (act/pas), SAT 86 dBuV
TERR 80/85 dBuV (act/pas), SAT 85 dBuV
Control DiSEqC 2.0
Current Consumption
80 mA (18 V DC) from each satellite receiver
Terr. Input Current 150 mA max (12 V DC)
Power Consumption
7 W / 5 W (act/pas) + consumption of devices connected to inputs
Dimensions (w,d,h) 47.0 x 15.2 x 8.7 cm (including power supply)
Temperature Range -30°C - +70°C
* TERR: EN 50083-3/60dB IMA3 [dBuV]; SAT: EN 50083-3/35dB IMA3 [dBuV] avg - average value, there is tolerance of ±4 dB in specified range, min - minimum value, act/pas
- active/passive mode of terrestrial band
10 S ymbols Explanation
certificate of conformity
international standard for digital satellite equipment control, number (1.0, 1.1, 1.2 or 2.0) determines DiSEqC version.
for indoor use only
DC power supply
protective bonding
class II device
fuse protected
safety transformer
According to EU directive, electric and electronic devices which are identified by one of the following symbols must not be disposed of together with municipal waste. When disposing of the old device, use local waste collection and separation systems.
11 Wiring Diagrams
Loading...