![](/html/20/2084/20841ef71fd25bb088a3b5e9bf33e35822c676600261f6b15ed655f36a7d3a67/bg1.png)
INSTRUCTION MANUAL
GAS COOKTOP
Appliance Class: 3
Empava Item #:
24 " :EMPV-24GC4B67A EMPV-24GC4L67A
30 " :EMPV-30GC5B70C EMPV-30GC5L70A
34 " :EMPV-34GC5B90A EMPV-34GC5B90C EMPV-34GC5L90A
36" : EMPV-36GC5B90S EMPV-36GC5L90I
Distributed by:
Empava Appliances Inc.
15253 Don Julian Rd, City of Industry, CA 91745 USA
www.empava.com
The instructions shall be marked with directions to the installer to leave them with
the appliance and to the consumer to retain them for future reference.
![](/html/20/2084/20841ef71fd25bb088a3b5e9bf33e35822c676600261f6b15ed655f36a7d3a67/bg2.png)
WARNING:
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance
shall not be made by children without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer. its service agent or
similarly qualified persons in order to avoid a hazard.
The disconnection may be achieved by having the plug accessible or by incorporating a switch
in the fixed wiring in accordance with the wiring rules.
WARNING:
If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or
any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch.
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s
instructions.
![](/html/20/2084/20841ef71fd25bb088a3b5e9bf33e35822c676600261f6b15ed655f36a7d3a67/bg3.png)
Contents
◆ Cooktop Description
◆ Important Information
◆ Operation
◆ Maintenance and Cleaning
◆ Troubleshooting
◆ Instructions for the Installer
◆ Important safety requirements
◆ Installation
This appliance shall be installed in accordance with the regulations in force and only used in a wellventilated space.
Read the instructions before installing or using this appliance.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 or, in Canada, the Natural Gas and Propane Installation Code, CSA
B149.1.
The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, NFPA 70 or the Canadian Electric Code, CSA
C22.1‐02.
![](/html/20/2084/20841ef71fd25bb088a3b5e9bf33e35822c676600261f6b15ed655f36a7d3a67/bg4.png)
Cooktop Description
Figure 1
Figure 2
Figure 3
Figure 4
Operating Instructions:
Knob 5 is for burner 4
Knob 6 is for burner 1
Knob 7 is for burner 3
Knob 8 is for burner 2
Operating Instructions:
Knob 5 is for burner 4
Knob 6 is for burner 1
Knob 7 is for burner 3
Knob 8 is for burner 2
Total heat input: 31600Btu/hr
Total heat input: 31600Btu/hr
1.burner 1 — 3400Btu/hr in 1.77”
2.burner 2 — 12000Btu/hr in 5.20"
3.burner 3 — 6000Btu/hr in 2.56"
4.burner 4 — 10200Btu/hr in 3.74"
1.burner 1 — 3400Btu/hr in 1.77”
2.burner 2 — 12000Btu/hr in 5.20"
3.burner 3 — 6000Btu/hr in 2.56"
4.burner 4 — 10200Btu/hr in 3.74"
Operating Instructions:
Knob 1 is for burner 10
Knob 2 is for burner 9
Knob 3 is for burner 8
Knob 4 is for burner 7
Knob 5 is for burner 6
1.burner 6—6000Btu/hr in 2.56"
2.burner 7—10200Btu/hr in 3.74"
3.burner 8—12000Btu/hr in 5.20"
4.burner 9—6000Btu/hr in 2.56"
5.Burner 10—3400Btu/hr in 1.77”
Total heat input: 37600Btu/hr
Operating Instructions:
Knob 1 is for burner 10
Knob 2 is for burner 9
Knob 3 is for burner 8
Knob 4 is for burner 6
Knob 5 is for burner 7
1.burner 6—3400Btu/hr in 1.77”
2.burner 7—10200Btu/hr in 3.74"
3.burner 8—6000Btu/hr in 2.56"
4.burner 9—6000Btu/hr in 2.56"
5.Burner 10—12000Btu/hr in 5.20"
Total heat input: 37600Btu/hr
![](/html/20/2084/20841ef71fd25bb088a3b5e9bf33e35822c676600261f6b15ed655f36a7d3a67/bg5.png)
Figure 5
Figure 6
Figure 7
Figure 8
Operating Instructions:
Knob 1 is for burner 10
Knob 2 is for burner 6
Knob 3 is for burner 8
Knob 4 is for burner 7
Knob 5 is for burner 9
Operating Instructions:
Knob 1 is for burner 10
Knob 2 is for burner 9
Knob 3 is for burner 8
Knob 4 is for burner 7
Knob 5 is for burner 6
Total heat input: 37600Btu/hr
Total heat input: 37600Btu/hr
1.burner 6—6000Btu/hr in 2.56"
2.burner 7—3400Btu/hr in 1.77”
3.burner 8—10200Btu/hr in 3.74"
4.burner 9—6000Btu/hr in 2.56"
5.Burner 10—12000Btu/hr in 5.20"
1.burner 6—6000Btu/hr in 2.56"
2.burner 7—10200Btu/hr in 3.74"
3.burner 8—12000Btu/hr in 5.20"
4.burner 9—6000Btu/hr in 2.56"
5.Burner 10—3400Btu/hr in 1.77"
Operating Instructions:
Knob 1 is for burner 10
Knob 2 is for burner 9
Knob 3 is for burner 8
Knob 4 is for burner 7
Knob 5 is for burner 6
1.burner 6—6000Btu/hr in 2.56"
2.burner 7—10200Btu/hr in 3.74"
3.burner 8—12000Btu/hr in 5.20"
4.burner 9—6000Btu/hr in 2.56"
5.Burner 10—3400Btu/hr in 1.77”
Total heat input: 37600Btu/hr
Operating Instructions:
Knob 1 is for burner 10
Knob 2 is for burner 7
Knob 3 is for burner 9
Knob 4 is for burner 6
Knob 5 is for burner 8
1.burner 6—6000Btu/hr in 2.56"
2.burner 7—3400Btu/hr in 1.77”
3.burner 8—10200Btu/hr in 3.74"
4.burner 9—12000Btu/hr in5.20"
5.Burner 10—600Btu/hr in 2.56"
Total heat input: 37600Btu/hr
![](/html/20/2084/20841ef71fd25bb088a3b5e9bf33e35822c676600261f6b15ed655f36a7d3a67/bg6.png)
Figure 9
Important Information
Read the instructions before installing or using this appliance.
Children should be supervised to ensure that they do not play with the appliance.
These instructions are only valid if the country symbol appears on the appliance. If the symbol does not
appear on the appliance, it is necessary to refer to the technical instructions which will provide the
necessary instructions concerning modification of the appliance to the conditions of use of the country.
Installation
➢ Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure)
and the adjustment of the appliance are compatible.
➢ The adjustment conditions for this appliance are stated on the label (or data plate).
➢ This appliance is not connected to a combustion products evacuation device. It shall be installed
and connected in accordance with current installation regulations. Particular attention shall be
given to the relevant requirements regarding ventilation. Read the instructions before installing or
using this appliance.
➢ The appliance and its individual shut-off valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
➢ The appliance must be isolated from the gas supply piping system by closing its individual manual
shut-off valve during any pressure testing of the gas supply piping system at test pressures equal
to or less than 1/2 psi (3.5 kPa).
➢ Always check for the validity of the pressure regulator. Technical specification of the pressure
regulator:
i. Refer to TECHNICAL DATA in this manual.
ii. Max. consumption: 2.5kg/h.
iii. Should be certified according to ANSI Z21.1 / CSA 1.1 and comply with local code.
➢ This appliance must be installed and serviced by a competent person
➢ This appliance shall be installed in accordance with the regulations in force and only used in a well
ventilated space.
➢ Remove all packaging before using the gas cooktop
➢ Ensure that the gas and complies with the type stated on the rating label
➢ Do not attempt to modify the gas cooktop in any way
Caution: This appliance is for cooking purposed only. It must not be used for other purposes, for
example room heating.
1.burner 6—6000Btu/hr in 2.56"
2.burner 7—10200Btu/hr in 3.74"
3.burner 8—12000Btu/hr in 5.20"
4.burner 9—6000Btu/hr in 2.56"
5.Burner 10—3400Btu/hr in 1.77"
Operating Instructions:
Knob 1 is for burner 10
Knob 2 is for burner 9
Knob 3 is for burner 8
Knob 4 is for burner 7
Knob 5 is for burner 6
Total heat input: 37600Btu/hr