EMIX EMMA-45, EMMA-60, EMMA-120 User Manual

Pro
Professional Public Address System
fessional Public Address System
ProPro
EMI
fessional Public Address Systemfessional Public Address System
EMMA-45 EMMA-60
EMMA-120
USER MANUAL
Before operating, please read this manual completely
FEATURES:
5 MIC inputs, 2 AUX inputs, 1 Record input, 1 Record output
Priority muting for chime and siren
Three levels of priority muting: MIC1
siren
chime
5 LED level meter
Individual volume control for each input, master bass and treble control
Speaker outputs 100V, 70V and 4
Power supply AC 220V-240V or DC 24V
Thermal, over load, short circuit protection and siren
1
Left blank for memo
2
FRONT PANEL
1
2
3
4 5
1Led Power Indicator 7. Treble Control
2. Power Switch 8. Mic1, 2, 3 Volume Control
3. Led Level Meter 9. Mic4 / Aux1 Volume Control
4. Chime 10. Mic5 / Aux2 Volume Control
5. Siren 11. 6.3mm Jack Type Mic1 Input
6. Bass Control
6
NOTE: adjusting each volume control button till LED 4 (+8dB) and LED 5 (+10dB) flash.
When all 5 LED level meters remain lit, sound is distorted. In such case,
7
9
10
8
11
REAR PANEL
1
3
2
4
5
6
7
1. Mic2 : XLR Input 7. Fan Exhaust Window 14. Record output or
2. Mic2 : 6.3mm Input 8. AUX 1 / Mic4 Switch Amplifier link
3. Mic3 : 6.3mm Input 9. Mic4 : 6.3mm Input 15. Record input
4. Mic3 : XLR Input 10. AUX 1 : Line Input 16. 24V DC Fuse
5. Output Terminals 11. AUX 2 : Line Input 17. AC Power cord
6. 24V DC Supply Input 12. AUX 2 / Mic5 Switch 18. AC Fuse
Terminal 13. Mic5 : 6.3mm Input
9
8
10
11
12
13
14 15
16
17
18
3
CONNECTION
MIC5
MIC
4
MIC
2 MIC
3
LOW
DISC
108.75
CD PLAYER
IMPEDANCE SPEAKER
100V, 70V, LINE
SPEAKER
24V
OPEN
TAPE RECORDER
CD PLAYER
1 3
2
00:35
OPEN
2
(6.3mm Socket )
(6.3mm Socket)
Speaker output terminals are on the rear panel. The terminal under the label “COM” is COMMON.
The terminals under the labels “4, 70V, 100V” are Hot. The connection ways shall be COM-4 /
COM-70V / COM-100V.
Normally the “rated power” (70V / 100V) output terminal is used in output connection. The
connected speaker should be with a transformer, and the gross power of speakers should be less
than the rated power of the amplifier.
“Rated Impedance”(4-16) output terminal can be used when speakers are fixed closely, and the
gross impedance of speakers should be 4-16.
Note:
Never connect two hot terminals (labeled 4, 70V, 100V) together. Only choose one pair of output terminals for speaker connection. The connection ways
shall be COM-4 / COM-70V / COM-100V.
4
Tone and volume:
MIC1, 2, 3, 4, 5 have separate volume control. MIC4 and AUX1 or MIC5 and AUX2 have a common
volume control knob.
MIC
: MIC inputs are balanced with phantom power. Two types of MIC inputs available: 6.3mm
(MIC1, 4, 5) and XLR (MIC2, 3). MIC4 & 5 inputs are compatible with AUX1 & 2 inputs.
“MIC4/AUX1” and “MIC5/AUX2” can be selected through the switches on the back panel. MIC1 has
the highest level of priority muting function and can override all input signals.
Note: To prevent howling, keep volume level down to minimum before connecting microphone.
“BASS” and “TREBLE” knob provides the tone control of overall system.
Chime / Siren:
The LED indicator above the button will be lit up simultaneously. Pressing the “SIREN” button again
will stop siren broadcasting and the LED will be turned off.
Levels of priority muting:
has the highest level of priority muting and can override all other input signals. Siren has the second
level. Chime has the third level and can override all input signals except for MIC1 and siren.
REC input / output:
cassette player, etc.) The volume of this input is not adjustable. While recording program signal can
send to REC input and at the same time signal send out to recording equipment through REC
output. REC output also can be used for monitoring the other input signals.
Pressing the “CHIME” / “SIREN” button will activate the chime or siren circuitry.
MIC1, siren and chime have priority muting functions. MIC1
REC input can connect to an external source (CD player, tuner,
PRECAUTION OF INSTALLATIOM
1. Do not block ventilation holes.
2. Do not use this amplifier if the power cord is frayed or broken.
3. The amplifier should not be placed in any of the areas:
1) poor ventilation
2) exposed to sunlight directly
3) high ambient temperature or adjacent to heat-generating equipment;
4) high humidity or heavy dust;
5) Susceptible to vibration.
4. Make sure the plug conforms to the socket.
5. For safety, please make grounding.
6. Short-circuit fault happens when short alarm rings during operation, In such case, switch off the
power immediately and check the faults before switching on again.
SPECIFICATIONS
5
:
Model EMMA-45 EMMA-60 EMMA-120
Rated Output 45W RMS 60W RMS 120W RMS
Output
Regulation Ratio
Speaker Output
REC Output
Inputs
Frequency
Response
Distortion
S/N Ratio
Tone Control
Protection
Muting
Function
Less than 3dB from no-load to full load
4 Balanced70V100V
600 1V
MIC1, 2, 3, 4, 5: 600, 6mV Balanced
AUX 1, 2: 10K, 270mV unbalancedREC IN10K300mV
Line50Hz-20KHz (±3dB)Microphone100Hz-10KHz (±3dB)
< 0.5% at 1KHz , 1/3rated power
MIC1, 2, 3, 4, 5: 70dB
AUX1, 2: 75dB
Bass: ±12dB at 100Hz
Treble: ±12dB at 10KHz
AC fuses, DC fuses, overload, short circuit
MIC1 overrides other input signals (Attenuation: 0 to -30dB)
SIREN overrides other input signalsexcept MIC1Attenuation: 0 to -30dB
CHIME overrides other input signalsexcept MIC1,SIREN(Attenuation: 0 to
-30dB)
Power Supply
AC220-240V/50-60Hz, DC24V
Requirements
Power
80W 100W 200W
Consumption
Dimensions
Gross Weight
Net Weight
Specifications are subject to change without notice
430×360×88mm 430×360×88mm 430×360×88mm
10.3kg 11.3kg 13kg
9.3kg 10.2kg 11.9kg
CAUTION
For safety, when “Power switch” is off, please detach the power plug from the power point.
The apparatus shall not be exposed to dripping or plashing and no objects filled with liquids,
such as vases, shall be placed on the apparatus.
To reduce the risk of electric shock, do not remove the cover.
No user serviceable parts inside. Refer servicing to qualified service personnel.
6
Loading...