Specication
Nominal Basket Diameter Nominal Impedance* Power Rating** Watts Music Program Resonance Usable Frequency Range*** Sensitivity Magnet Weight Gap Height Voice Coil Diameter
Thiele & Small Parameters
Resonant Frequency (fs) DC Resistance (Re) Coil Inductance (Le) Mechanical Q (Qms) Electromagnetic Q (Qes) Total Q (Qts) Compliance Equivalent Volume (Vas) Peak Diaphragm Displacement Volume (Vd) Mechanical Compliance of Suspension (Cms) BL Product (BL) Diaphragm Mass inc. Airload (Mms) Efciency Bandwidth Product (EBP) Maximum Linear Excursion (Xmax) Surface Area of Cone (Sd) Maximum Mechanical Limit (Xlim)
12”, 304.8mm
4 ohms
500W
1000W
52Hz
45Hz-2.3kHz
93.1
56 oz.
0.375”, 9.53mm
2.5”, 63.5mm
52Hz
3.2
.94mH
8.21 .47 .44
63.7 liters / 2.3 cu.ft. 249cc
0.17mm/N
10.9 T-M
53 grams
111.4
4.8mm
519.5 cm2
13.5mm
The Art and Science of Sound
DELTA-12LFC Neodymium Series
Recommended for professional audio mid-bass or oor monitor applications in a sealed enclosure. Also suitable as a woofer in vented, bass guitar or PA enclosures.
Mounting Information
Recommended Enclosure Volume Sealed Vented Driver Volume Displaced Overall Diameter Bafe Hole Diameter Front Sealing Gasket Rear Sealing Gasket Mounting Holes Diameter Mounting Holes B.C.D. Depth Net Weight Shipping Weight
28-110 liters/1.0-3.9 cu.ft.
Materials of Construction
Copper voice coil Kapton Ferrite magnet Vented and extended core Pressed steel basket Treated Paper Cone Cloth cone edge Solid composition paper dust cap
21-74 liters/0.7-2.6 cu.ft.
137.3 cu.in. / 2.25 liters
12.03”, 305.5mm
10.95”, 278.1mm Fitted as standard Fitted as standard
0.25”, 6.4mm
11.59”, 294.4mm
5.88”, 149.35mm
11.8 lbs., 5.4 kg 14 lbs., 6.4 kg
Please inquire about alternative impedances.
*
Multiple units exceed published rating evaluated under EIA 426A noise source and test standard while in a free-air, non-temperature controlled environment.
**
The average output across the usable frequency range when applying 1W/1M into the nominal impedance. Ie: 2.83V/8ohms, 4V/16ohms.
***
Eminence response curves are measured under the following conditions: All speakers are tested at 1w/1m using a variety of test set-ups for the appropriate impedance | LMS using 0.25” supplied microphone (software
berglass on all six surfaces (three with custom-made wedges)