EMI enviroair 9000 Btu, enviroair 18000 Btu, enviroair 12000 Btu, enviroair 24000 btu Installation, Operation & Maintenance Manual

Presents
FSR Series
Single Zone 15SEER High-Wall
Ductless Inverter Split Systems
Installation, Operation &
Manintenance Manual
Condenser (Outdoor) Models: FCA
ECR International, Inc. 2201 Dwyer Avenue • Utica, New York 13501 Phone: 800.325.5279 • Web: enviromaster.com
An ISO 9001-2008 Certied Company
PN 240009906, Rev C [01/13/2014]
1
CONTENTS
SOCIABLE REMARK
SAFETY PRECAUTIONS
OPERATING INSTRUCTIONS
CARE AND MAINTENANCE
OPERATION TIPS
TROUBLESHOOTING TIPS
Sociable remark....................................................................................................................
Warning .................................................................................................................................
Caution ..................................................................................................................................
Parts names ........... ...........................................................................................................
Special functions ..................................................................................................................
Operating temperature..........................................................................................................
Manual operation ................................................................................................................
Airflow direction control .......................................................................................................
How the air conditioner works ..........................................................................................
Care and maintenance .......................................................................................................
Operation tips ............ .........................................................................................................
Troubleshooting tips ............................................................................................................
INSTALLATION PRECAUTIONS
SAFETY PRECAUTIONS
SELECT THE BEST LOCATION
INDOOR UNIT
INSTALLATION PLATE MOUNTING
DRILL A HOLE IN THE WALL
CONNECT THE CABLE TO THE INDOOR UNIT
CONNECTIVE PIPE AND DRAINAGE INSTALLATION
OUTDOOR UNIT
OUTDOOR INSALLATION PRECAUTION
DRAIN JOINT INSTALLATION
REFRIGERANT PIPE CONNECTION
CONNECT THE CABLE TO THE OUTDOOR UNIT AIR PURGING AND TEST OPERATION
...........................................................................................................
...........................................................................................................
...........................................................................................................
...........................................................................................................
...........................................................................................................
...........................................................................................................
...........................................................................................................
...........................................................................................................
...........................................................................................................
...........................................................................................................
............................................................................
...........................................................................................................
2
2
3
4 4 5
5
7 7
7 8 8
11
12 13
14 15
16 16
17 18
20
22
23
2
INSTALLATION MANUAL FOR
ROOM AIR CONDITIONER
(Split Wall-Mounted Type)
Please read these safety precautions carefully before installation Be sure to follow all the precautions below, they are all important for ensuring safety.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
1) This equipment must be grounded and installed with ground leakage current breaker. It may cause electrical shock if grounding is not perfect.
2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and
accumulates at surrounding of the unit, it may cause fire.
3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water
may enter the room and damage the furniture.
1) Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock,or fire.
2) Use the included accessories parts and specified parts for installation. otherwise, it will cause the set to fall, water leakage, electrical shock fire.
3) Install at a strong and firm location which is able to withstand the set s weight. If the strength is not
enough or installation is not properly done, the set will drop and cause injury.
4) For electrical work, follow the local national wiring standard, regulation and this installation instructions.
An independent circuit and single outlet must be used. If electrical circuit capacity is not enough or
defect found in electrical work, it will cause electrical shock fire.
5) Use the specified cable and connect tightly and clamp the cable so that no external force will be acted
on the terminal. If connection or fixing is not perfect, it will cause heat-up or fire at the connection.
6) Wiring routing must be properly arranged so that control board cover is fixed properly. If control board
cover is not fixed perfectly, it will overheat at connection point of terminal, fire or electrical shock.
7) When carrying out piping connection, take care not to let air substances other than the specified
refrigerant go into refrigeration cycle. Otherwise, it will cause lower capacity, abnormal high pressure
in the refrigeration cycle, explosion and injury.
8) Do not modify the length of the power supply cord or use of extension cord, and do not share the
single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.
SAFETY PRECAUTIONS
CAUTION
WARNING
CAUTION
WARNING
Please read this installation manual carefully before operating the unit to ensure correct installation. If the power cord is damaged, replacement work shall be performed by authorised personnel only. Installation work must be performed in accordance with the national wiring standards by authorised personnel only. Contact an authorized service technician for repair, maintenance and installation of this unit. This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by persons responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. All the pictures in the instructions are for explanation purposes only. The actual shape should prevail. The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.
INSTALLATION PRECAUTIONS
3
Except the above parts provided,the other parts needed during installation you must purchase.
ACCESSORIES
NOTE:
SELECT THE BEST LOCATION
There should not be any heat source or stream near the unit. There should not be any obstacles blocking the air circulation. A place where air circulation in the room is good. A place where drainage can be easily done. A place where noise prevention is taken into consideration. Do not install the unit near the door way. Ensure the spaces indicated by arrows from the wall,ceiling,fence or other obstacles. There should not be any direct sunlight. If unavoidable, sunlight prevention should be taken into consideration.
Out
do
or unit di
m
en
si
on
mm
(WxH
xD
)
A(mm)
458
460
B(mm)
250
276
530
600
290
320
560
481
335
276
549 276
Mounting dimensions
700x540x240
685x430x260
780x540x250
760x590x285
775x545x310
845x700x320
660x540x265
Indoor unit
Outdoor unit
If an awning is built over the unit to prevent direct sunsight or rain,be careful that heat radiation from the condenser is not obstructed. There should not be any animal or plant which could be affected by hot air discharged. Keep the spaces indicated by arrow from wall ceiling, fence or other obstacles. Do not place any obstacles which may cause a short circuit of the discharged air.
Anchor the outdoor unit with a bolt and nut 10 or
8 tightly and horizontally on a concrete or rigid mount.
Settlement of outdoor unit
NOTE: The outdoor unit you purchase may be like one of the following. Install the outdoor unit according to the dimension as indicated in the table below:
A
W
B
D
Air inlet
Air outlet
Air inlet
1
2
3 4
5
7 8
9 10
6
Installation Plate
Clip Anchor
Self-tapping Screw A ST3.9x25 Seal(For cooling & heating models only)
Drain Joint(For cooling & heating models only
Connecting pipe Assembly
Liquid side
Gas side
Remote controller
Air freshening filter(installed on Air filter)
Self-tapping Screw B ST2.9x10
6.35
9.52
9.52
12.7
16
Parts you must purchase. The pipe size differ from appliance to appliance. Consult the technician for the proper size.
1 5-8(depending on models) 5-8(depending on models)
1 1
1 2
1
1
Remote controller holder
Number
Name of Accessories
Qty
optional parts
4
1. Fit the installation plate horizontally on structural parts of the wall with spaces around the installation plate.
2. If the wall is made of brick, concrete or the like, drill five or eight 5mm diameter holes in the wall.Insert Clip anchor for appropriate mounting screws.
3. Fit the installation plate on the wall with five or eight type A screws.
Mount the Installation Plate and drill holes in the wall according to the wall structure and corresponding mounting points on the installation plate. The installation plate provided with the machine differ from appliance to appliance. (Dimensions are in mm unless otherwise stated)
1. Determine hole positions according to left and right side of the installation plate. The hole center is obtained by measuring the distance as shown in the diagram above.
2. Dirll the piping plate hole with 65mm hole-core drill.
3. Drill the piping hole at either the right or the left and the hole should be slightly slanted to the outdoor side.
4. Always take steps to protect the pipe when drilling metal grid,metal plate or the like.
DRILL A HOLE IN THE WALL
INSTALLATION PLATE MOUNTING
2
NOTE:
NOTE:
Installation Plate Mounting
1
The mounting wall is strong and solid enough to prevent it from the vibration.
" "
"
"
Right rear side refrigerant pipe hole 65
Right rear side refrigerant pipe hole 65
Right rear side refrigerant pipe hole 65
Left rear side refrigerant pipe hole 65
Left rear side refrigerant pipe hole 65
Left rear side refrigerant pipe hole 65
150mm or more to ceiling
Indoor unit outline
Indoor unit outline
Indoor unit outline
120mm or more to wall
120mm or more to wall
Correct orientation of Installation Plate
150mm or more to ceiling
120mm or more to wall
120mm or more to wall
45
4
5
4
5
45
4
5
36.5
4
5
4
5
41
41
41
9000Btu/h models(A:680, B:255, C:170, D:92)
12000Btu/h models(A:770, B:255, C:170, D:95)
18000Btu/h models(A:905, B:275, C:80, D:100)
AA
A
A
C
C
C
D
D
D
BB
B
B
150mm or more to ceiling
120mm or more to wall
120mm or more to wall
INDOOR UNIT
5
CONNECT THE CABLE TO THE INDOOR UNIT
3
,
Terminal block of indoor unit
Connect the cable to the indoor unit
Before performing any electrical work, turn off the main power to the system.
1. The inside and outside connecting cable can be connected without removing the front grille.
2. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw.
3. Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor s respectively.
4. Wrap those cables not connected with terminals with insulation tapes, so that they will not touch any electrical components. Secure the cable onto the control board with the cord clamp.
NOTE:
Electrical box cover
Front Panel
To outdoor unit
To outdoor unit
Cord clamp
4
CONNECTIVE PIPE AND DRAINAGE INSTALLATION
1. Run the drain hose sloping downward. Do not install the drain hose as illustrated in wrong figures.
2. When connecting extension drain hose, insulate the connecting part of extension drain hose with a shield pipe, do not let the drain hose slack.
Drainage
Right
Wrong
L N S
L N S
or
The cable size and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which located on the side panel of the unit. Please refer to the nameplate before selecting the cable, fuse and switch.
NOTE:
Suggest Minimum Wire Size (AWG: ):American Wire Gage
Appliance Amps
AWG Wire Size
10
13
18
25
18
16
14
12
30
10
Electric safety regulations for the initial Installation
1. If there is serious safety problem about the power supply, the technicians should refuse to install the air conditioner and explain to the client until the problem is solved.
2. Power voltage should be in the range of 90%~110%of rated voltage.
3. The surge protector and main power switch with a 1.5 times capacity of Max. Current of the unit should be installed in power circuit.
4. Ensure the air conditioner is grounded well.
5. According to the attached Electrical Connection Diagram located on the panel of the outdoor unit to connect the wire.
6. All wiring must comply with local and national electrical codes and be installed by qualified and skilled electricians.
7. An all-pole disconnection device which has at least 3mm separation distance in all pole and a residual current device(RCD) with the rating of not exceeding 30mA shall be incorporated in the fixed wiring according to the national rule.
8. An individual branch circuit and single receptacle used only for this air conditioner must be available. See the following table for suggested wire sizes and fuse specifications:
Electrical work
6
1. For the left-hand and right-hand piping, remove the pipe cover from the side panel.
2. For the right back and left back piping, install the piping as shown. NOTE:
3. Bundle the tubing, connecting cable, and drain hose with tape securely, evenly as shown in Figure on the right.
One side drainage structure is standard. Both sides drainage structure is optional and can only be customized from factory.For both sides drainage structure, it can be choosen for right, left or both sides drainage connection. If choosing both sides drainage connection, another proper drain hose is needed as there is only one drain hose offered by factory. If choosing one side drainage connection, make sure the drain hole on the other side is well plugged. For 9k/12k models, if choosing right side drainage connection, please choosing right-hand or right-back piping. The connection of the drain hose is supposed to be done by qualified installer in case of water leakage.
Connect the indoor unit first, then the outdoor unit. Do not allow the piping to let out from the back of the indoor unit. Be careful not to let the drain hose slack. Heat insulation should be done to the extension drain hose of indoor unit. Be sure that the drain hose is located at the lowest side of the bundle. Locating at the upper side can cause drain pan to overflow inside the unit. Never intercross nor intertwist the power wire with any other wiring.
1. Pass the piping through the hole in the wall.
2. Hook the indoor unit onto the upper portion of installation plate(Engage the indoor unit with the upper edge of the installation plate). Ensure the hooks are properly seated on the installation plate by moving it in left and right.
3. Piping can easily be made by lifting the indoor unit with a cushioning material between the indoor unit and the wall. Get it out after finish piping.
4. Press the lower left and right side of the unit against the installation plate until hooks engages with the their slots.
Connective pipe installation
CAUTION
Indoor unit installation
Because the condensed water from rear of the indoor unit is gathered in ponding box and is piped out of room. Do not put anything else in the box.
I
N D
O O R
U N
I
T
7
Install the outdoor unit on a rigid base to prevent increasing noise level and vibration. Determine the air outlet direction where the discharged air is not blocked. In the case that the installation place is exposed to strong wind such as a seaside, make sure the fan operating properly by putting the unit lengthwise along the wall or using a dust or shield plates. Specially in windy area, install the unit to prevent the admission of wind. If need suspending installation, the installation bracket should accord with technique requirement in the installation bracket diagram. The installation wall should be solid brick, concrete or the same intensity construction, or actions to reinforce, damping supporting should be taken. The connection between bracket and wall, bracket and the air conditioner should be firm, stable and reliable. Be sure there is no obstacle which block radiating air.
Strong wind
Strong wind
Barrier
Incorrect
Correct
Seal
Drain joint
Base pan hole of outdoor unit
(A)
(B)
The drain joint is slightly different according to the different outdoor unit. For the drain joint with the seal(Fig.A), first fit the seal onto the drain joint, then insert the drain joint into the base pan hole of outdoor unit, rotate 90 to securely assemble them. To install drain joint as shown in Fig.B, insert the drain joint into the base pan hole of outdoor unit until it remains fixed with a clicking sound. Connecting the drain joint with an extension drain hose (Locally purchased), in case of the water draining off the outdoor unit during the heating mode.
2
DRAIN JOINT INSTALLATION
OUTDOOR INSALLATION PRECAUTION
3
REFRIGERANT PIPE CONNECTION
1. Cut a pipe with a pipe cutter.
2. Put flare nuts on pipe/tube having completed burr removal and flare the pipe.
3. Firmly hold copper pipe in a die in the dimension shown in the table below.
Align pipes to be connected. Sufficiently tighten the flare nut with fingers, and then tighten it with a spanner and torque wrench as shown. Excessive torque can break nut depending on installation conditions.
Outer diam.
(mm)
A(mm)
Max.
Min.
6.35 1.3
0.7
9.52
1.6 1.0
12.7
1.8 1.0
12.7
16
1.8
2.2
1.0
2.0
Bar
Copper pipe
Clamp handle
Handle
Bar
"A"
Indoor unit tubing Flare nut Pipings
Outer diam.
Tightening
torque(N.cm)
Additional tightening
torque(N.cm)
6.35mm
12.7mm
16mm
9.52mm
1500
(153kgf.cm)
1600
(163kgf.cm)
3500
(357kgf.cm)
4500
(459kgf.cm)
3600
(367kgf.cm)
4700
(479kgf.cm)
2500
(255kgf.cm)
2600
(265kgf.cm)
Flaring
Tightening connection
1
NOTE:
Oblique
Roughness
Burr
O
90
OUTDOOR UNIT