Emfit safebed, D-1070-2G, L-4060SL Operation And Installation Instructions Manual

1
®
SafeBed™
Bed Occupancy Monitor
User’s Manual with Operation and Installation Instructions and
Warranty Terms
WARNING! MUST NOT BE USED IN SITUATIONS WHERE A MALFUNCTION
OR A LATENT DESIGN FLAW IN THE PRODUCT COULD LEAD TO A DELAY IN
DELIVERY OF APPROPRIATE MEDICAL CARE OR THAT WOULD LIKELY LEAD
TO A POTENTIALLY LIFE THREATENING SITUATION
Applicable model numbers:
Control Unit D-1070-2G, version t46 v1.0.3 (50 Hz) or newer
Under Mattress Bed Sensor L-4060SL
Date June 27th, 2008. V2.1
Emfi, Emfit and Emfit logo are either registered trademarks or trademarks of Emfit Ltd in EU, USA, Japan and/or other countries. Copyright © 2002-2008 Emfit Ltd. All rights reserved. Patented, patents pending. List of patents is seen at manufacturer’s website www.emfit.com.
2
TABLE OF CONTENTS
DANGER NOTES ....................................................................................................................................................... 2
OTHER SYMBOLS USED............................................................................................................................................. 2
1. GENERAL INFORMATION............................................................................................................................................ 3
Intended Use........................................................................................................................................................... 3
Control Unit............................................................................................................................................................. 3
Under Mattress Bed Sensor ....................................................................................................................................... 3
2. PACKAGE CONTENTS ................................................................................................................................................ 3
3. BEFORE USE SELECT THE RIGHT DIP SWITCH SSETTINGS ............................................................................................ 3
Table of DIP Switch Settings...................................................................................................................................... 4
Setting the Notification Time Delay............................................................................................................................. 4
Setting the Notification Sound Volume........................................................................................................................ 4
4. SETTING THE SENSITIVITY........................................................................................................................................ 4
5. INSTALLING THE BED SENSOR BELOW MATTRESS ....................................................................................................... 5
6. CONNECTORS AND WIRING....................................................................................................................................... 5
X2 (AUX) Connector Pin Order ................................................................................................................................... 6
7. INSTALLING THE WALL MOUNT AND DEVICE ............................................................................................................... 6
8. INSTALLING BATTERIES AND BATTERY CONSUMPTION ................................................................................................. 6
9. ABOUT THE OPTIONAL 5V AC ADAPTER....................................................................................................................... 7
10. LED-Light indicators ................................................................................................................................................ 7
11. SW1 - RESET SWITCH / ON-OFF SWITCH .................................................................................................................. 8
As Reset Switch ....................................................................................................................................................... 8
As On-Off Switch...................................................................................................................................................... 8
12. TESTING AND INSPECTIONS .................................................................................................................................... 8
Weekly Inspection.................................................................................................................................................... 8
Tests When Taking into Use and Every Month.............................................................................................................. 8
13. TROUBLESHOOTING................................................................................................................................................ 8
14. CLEANING.............................................................................................................................................................. 9
15. IMPORTANT SAFETY PRECAUTIONS........................................................................................................................... 9
16. MATERIALS DISPOSAL...........................................................................................................................................10
17. DECLARATION OF CONFORMITY (EU).......................................................................................................................10
18. EMFIT LIMITED WARRANTY STATEMENT...................................................................................................................10
19. TECHNICAL SPECIFICATIONS..................................................................................................................................12
20. ELECTROMAGNETIC CONDITIONS............................................................................................................................12
21. MANUFACTURER’S CONTACT INFORMATION..............................................................................................................15
DANGER NOTES
THE FOLLOWING NOTES ARE PROVIDED FOR BOTH YOUR PERSONAL SAFETY AND TO PROTECT THE DESCRIBED PRODUCT OR ATTACHED DEVICES FROM DAMAGE.
SAFETY NOTES AND WARNINGS FOR THE PREVENTION OF DANGER TO THE LIVES AND HEALTH OF USERS OR MAINTENANCE PERSONNEL AND/OR FOR THE AVOIDANCE OF DAMAGE TO PROPERTY ARE EMPHASISED IN THESE INSTRUCTIONS BY THE PICTOGRAMS DEFINED HERE. THE PICTOGRAMS USED HAVE THE FOLLOWING MEANINGS FOR THESE INSTRUCTIONS:
Means that death, serious personal injury or substantial damage to property can occur if the appropriate precautionary measures are not taken.
Means important information about the product or a part of the instructions that particular attention should be paid to.
OTHER SYMBOLS USED
All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. Our printed and electronically stored literature is purely advisory and, therefore, we bear no legal responsibility for the information provided. W e reserve the right to make changes and modifications without prior notification in the interest of continual improvements of our systems and components.
Upper storage temperature limit
Use by
3
1. GENERAL INFORMATION
Intended Use
The Emfit SafeBed™ Bed Occupancy Monitor (device model D-1070-2G and sensor model L-4060SL) is intended to be used for monitoring bed occupancy and giving notification when no occupancy is detected. The product consists of a bed sensor and a control unit. The control unit has an audible notification sound and a dry-contact output for connecting it to the other parts of the system.
Control Unit
The control unit D-1070-2G activates after it has noticed movements or micro- movements, such as those caused by respiratory movements or the heart beating, for over 40 seconds. Notification is triggered if no movements or micro-movements are detected for at least 5 seconds.
The control unit processes a low voltage (from about 1 mV up to about 1 V), high impedance signal from the dynamic, quasi-piezoelectric type (i.e. self­biased) flexible film-like sensor.
The control unit operates with 2 pcs AA size 1.5 V alkaline batteries. An optional AC adapter is available (5 VDC). AC ADAPTERS OTHER THAN ORIGINAL ACCESSORIES FROM EMFIT MUST NOT BE USED.
The control unit has input connectors for the sensor (marked as X3) and optional AC adapter (marked as X1). There is also a connector marked as X2 for connecting the device to other systems for transferring the notification via dry-contact optocoupler. A reset switch for turning off the notification sound is to the right of the sensor input (marked as SW1).
Inside the device there is a place for 2 pcs AA size 1.5 V alkaline batteries, and mini-switches (DIP and rotary) for program settings.
Under Mattress Bed Sensor
The Emfit under mattress bed sensor model L-4060SL is a quasi­piezoelectric, dynamic sensor that has no embedded wires or switches. This specially formulated plastic sheet sensor is placed beneath the mattress, crosswise to the bed, below the chest area.
The sensor produces signals from even the slightest micro-movements created when a person is in bed. When there is no movement, it recognizes this as the individual being absent and it gives a notification both by sound and via dry-contact optocoupler. There are no particular size or weight limitations, but sensitivity and ability to recognize user’s micro-movements and thus presence in bed need to be tested in each case.
2. PACKAGE CONTENTS
- Control unit
- Bed sensor
- Wall mounting clip
- 2 screws
- 2 locking anchors
- This user’s manual
- Optionally a power supply
3. BEFORE USE SELECT THE RIGHT DIP SWITCH SETTINGS
Inside the device there is a DIP switch with 8 small switches. These are used for various program settings.
See the following table and set up the switches for your preferred way.
To open the device cover, see the picture on right.
Open the cover by lifting from one side
4
Table of DIP Switch Settings
Switch # OFF (down) ON (up)
#1 Notification time delay setting, see next chapter Notification time delay setting, see next chapter
#2 Notification time delay setting, see next chapter Notification time delay setting, see next chapter
#3 Shortest notification time 5 seconds Shortest notification time 10 seconds
#4 Normal sensitivity for noticing micro-movements;
use when sensor is installed below foam mattress or mattress pad
Increased sensitivity for noticing micro-movements. Recommended use only when sensor needs to be installed below spring mattress (no mattress pad in use). NOTE! Consumes more power and shortens battery life! Blue light blinks slightly faster.
#5 Dry-contact output is pulse mode (about 1 sec
pulse)
Dry-contact output is constant type. Use only when necessary by other system to be connected with. Not to be used with batteries! Only with optional power supply due increased power consumption.
#6 Power switch function at SW1 is enabled (device
can be shut down and turned on by pressing SW1 for about 3 seconds)
Power switch function at SW1 disabled (device is always on).
#7 Notification sound volume setting, see after next
chapter
Notification sound volume setting, see after next chapter
#8 Notification sound volume setting, see after next
chapter
Notification sound volume setting, see after next chapter
Setting the Notification Time Delay
Time Delay Switch # 1 Switch #2
Shortest (5 or 10 sec)
OFF (down) OFF (down)
15 minutes ON (up) OFF (down)
30 minutes OFF (down) ON (up)
60 minutes ON (up) ON (up)
Setting the Notification Sound Volume
The notification sound is useful only when caregiver is in close proximity to the control unit. The volume can be adjusted at 4 levels: no sound, quiet, loud, and very loud.
Volume level Switch # 7 Switch #8
Very Loud OFF (down) OFF (down)
Loud ON (up) OFF (down)
Quiet OFF (down) ON (up)
No sound / mute ON (up) ON (up)
The sound stops when both the reset switch is pressed and when the event is over. In case of person’s absence from the bed, the sound will stop once person has returned or reset is pressed.
ALWAYS REMOVE BATTERIES AND UNPLUG THE AC ADAPTER (IF IN USE) BEFORE MAKING CHANGES TO THE DIP SWITCH POSITIONS. OTHEWISE THE NEW SETTINGS WILL NOT TAKE EFFECT.
4. SETTING THE SENSITIVITY
Sensitivity can be adjusted with 10 position rotary switch inside. Factory default setting is the pointer pointing to #3. In case device does not notice individual’s micro-movements, adjust sensitivity higher by turning the pointer clock-wise one position per time. If the device notices
5
movements even though no one is in bed, lower sensitivity by turning the screw counter-clockwise one position per time. Always test after every change before taking into use.
5. INSTALLING THE BED SENSOR BELOW MATTRESS
ALWAYS INSTALL THE SENSOR CROSSWISE TO THE BED AT THE POSITION BELOW THE CHEST.
CHECK THE CORRECT PLACEMENT OF THE SENSOR AT LEAST ONCE A WEEK.
IF YOU USE THE SENSOR ON A SPRING MATTRESS, PLACE THE SENSOR BETWEEN THE MATTRESS PAD AND THE SPRING MATTRESS!
IF THE BED HAS A SPRING MATTRESS, WITHOUT MATTRESS PAD, AND A BOX OR A SPRING BOX BELOW SPRING MATTRESS, SENSOR CAN BE INSTALLED BETWEEN THE SPRING MATTRESS AND THE BOX. IN THAT CASE INSTALL A DURABLE, 2-3 MM THICK PLASTIC OR PLYWOOD SHEET ON TOP AND BELOW THE SENSOR TO AVOID THE SPRINGS DAMAGING THE SENSOR. A THIN SOFT CUSHION BETWEEN THE SHEETS AND SENSOR IS PREFERRED. SET DIP SWITCH #4 UP.
THE SENSOR MUST ALWAYS BE PLACED BENEATH A MATTRESS OR MATTRESS PAD. THE SENSOR MUST NOT BE IN DIRECT CONTACT WITH A PERSON!
THE EMFIT BED SENSOR IS DESIGNED TO WITHSTAND USE BELOW A MATTRESS, AGAINST A HARD BED BOTTOM FOR 4 – 5 YEARS OF USE. MANUFACTURER RECOMMENDS REPLACING IT AFTER 6 YEARS FROM MANUFACTURING DATE OR AFTER 5 YEARS OF USE, WHICHEVER COMES FIRST.
WHEN USED ON TOP OF A SPRING MATTRESS, THE USE TIME IS MUCH SHORTER DUE TO MORE WEAR AND TEAR IS CAUSED WHEN PERSON IS IN BED. THIS WEAR AND TEAR CAUSES THE SENSOR TO WRINKLE. WITH SPRING MATTRESSES, A PERSON’S WEIGHT AND RESTLESSNESS CAN AFFECT THE USE TIME. THE ESTIMATED USE TIME IN A SPRING MATTRESS BED IS 1–2 YEARS. IF USED IN SUCH CIRCUMSTANCES, MANUFACTURER RECOMMENDS REPLACING THE SENSOR LATEST AFTER 3 YEARS OF USE. WARRANTY DOES NOT APPLY IF BED SENSOR IS DAMAGED DUE TO NORMAL WEAR AND TEAR!
DO NOT USE WITH ANTI-DECUBITUS MATTRESS (USED FOR PREVENTING BED-SORES), WHERE AIR PRESSURE IS
CONTROLLED WITH COMPRESSOR.
6. CONNECTORS AND WIRING
Connectors are marked with X1, X2 and X3. These are:
X1 - Power supply connector. Use only GlobTek Inc. power supply, model no:
GTM41060-1505 and P/N:WR9QA3000LCP-N-MNK, available as original accessory from Emfit.
X2 - Aux connector for connecting the device to some other system (cable not
included) for transferring the notification via a dry-contact optocoupler. DRY-CONTACT OUTPUT OF THE X2 (AUX) CONNECTOR CAN ONLY BE CONNECTED TO A SYSTEM SAFETY VOLTAGE INPUT WITH MAX VOLTAGE BELOW 25V (AC) / 60V (DC), WHERE BOTH POLES HAVE BEEN SEPARATED FROM THE ELECTRICAL NETWORK (SO CALLED FLOATING APPLIED PART). MAX LOAD CURRENT 100 mA!
X3 - Sensor connector (use only Emfit bed sensor model L-4060SL)
Connect the under mattress sensor, optional AC adapter and possible connection wire to other system as follows:
Connect the sensor wire plug to the control unit X3 marked connector.
If you need to connect the dry­contact output to another system, plug the suitable connection wire to the X2 marked connector
Connect the optional AC adapter cord to the X1 marked connector