Emerson WELLAND CF610VS00, WELLAND CF610VNB00 Owner's Manual

READ AND SAVE THESE INSTRUCTIONS
WELLAND™
54” Wet Location Ceiling Fan
Owner's Manual
Model Numbers
CF610VNB00 CF610VS00 - Vintage Steel
Net Weight: 24.9 Lbs.
Questions, problems, missing parts: Before returning to the store call
Emerson Electric Customer Service
8 a.m. - 6 p.m., Eastern, Monday-Friday
- Venetian Bronze
Part No. F40BP74950000 Form No. BP7495 Revision: 150216 E.T.L. Model No.: CF610
1-800-654-3545
• Español - página 25
• Français - page 49
Table of Contents
Section Page
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1. Unpacking Instructions . . . . . . . . . . . . . . . . . . . . .3-4
. Electrical Requirements . . . . . . . . . . . . . . . . . . . . .4
2
3. Ceiling Fan Assembly . . . . . . . . . . . . . . . . . . . . .5-9
4. How to Hang Your Ceiling Fan . . . . . . . . . . . .10-11
5. How to Wire Your Ceiling Fan . . . . . . . . . . . . .12-14
6. Using Your Ceiling Fan . . . . . . . . . . . . . . . . . . . . .15
7. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
READ AND SAVE THESE INSTRUCTIONS
Safety Instructions
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PE R S O NS, OBSER V E T H E FOLLOWING:
a. Use this unit only in a manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off
at servic e p a n e l and lock serv i c e pa nel disconnecting means to prevent power from being switch e d o n accide n t a lly. Whe n t h e servic e disconnecting means cannot be locked, securely fa sten a w arnin g devi ce, su ch as a tag , to the service panel.
1. Read your owner’s manual carefully and keep it for future reference.
2. Be careful with the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
3. Do not put anything into the fan blades while they are turning.
4. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for
Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National El e c trical C o de “ANSI / N FPA 70- 2 0 14” and Loc a l Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical sh ock. El e ctrica l insta l lation sho uld be made o r approved by a licensed electrician.
!
Section Page
8. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
. Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . .17
9
10. Repair Parts . . . . . . . . . . . . . . . . . . . . . . . . . .18-19
Ceiling Fan Limited Warranty . . . . . . . . . . . . . . . . . .23
Spanish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
French . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use the mounti n g screw s p r o v ided with th e o u t l et box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To reduce the risk of electrical shock, this fan must be ins tal led with an isol ati ng wall control/ switch.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
NOTE: All setscrews must be checked and re-tightened where necessary before installation.
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should
record this data above and keep it in a safe place for future use.
E.T.L. Model No.: CF610
2
H
F
B
D
E
C
G
A
I
1. Unpacking Instructions
5
4
1
2
3
12
11
8
10
9
7
6
WARNING
Do not install or use fan if any part is damaged or missing. Call Toll-Free for replacement parts:
!
1-800-654-3545
WARNING
This product is desig ned to use o nly those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerso n E lectri c C o . Subs t i t ution o f p arts o r accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
!
1.1
Check to see that you have received the following parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration below.
HARDWARE BAG CONTENTS
Part Description Quantity
1 Threaded Studs, #8-32 x 1-1/4” 2
2 Knurled Knobs, #8-32 2 3 Lockwashers, External Tooth #8 2 4 Wire Connectors 3 5 Clevis Pin 1 6 Hairpin Clip 1 7 1/4-20 x 1/2” Round Head Screws
with Lockwashers 11 8 #10-32 x 5/16” Washer Head Screws 16 9 #8-32 x 5/16” Flat Head Screw (spare) 1 10 #8-32 x 5/16” Round Head Screw (spare) 1 11 Wood Ball Pendant & Coupling 1 12 Blade Balance Kit 1
PACKAGE CONTENTS
Part Description Quantity
A Fan Motor Assembly 1
B Ceiling Cover 1
C Motor Coupler Cover 1 D Switch Housing Adapter 1 E Switch Housing Assembly 1
F Hanger Bracket 1 G Hanger Ball/4.5” Downrod Assembly 1 H Fan Blade Flanges 5
I Fan Blades 5
NOTE: Place the parts from the loose parts bags in
a small container to keep them from being lost.
If an y part s are m i ssin g , call 1 -800 - 654- 3 545
for replacement parts before proceeding.
emersonfans.com
Please contact 1-800-654-3545 for further assistance
3
E.T.L. Model No.: CF610
1. Unpacking Instructions (Continued)
THIS FAN IS SUITABLE FOR WET LOCATIONS SUCH AS PORCHES, PATIOS, AND DECKS.
USE ONLY WITH LIGHT KITS MARKED SUITABLE FOR USE IN WET LOCATIONS.
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver One stepladder One Standard screwdriver One wire stripper
Materials
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of following size:
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
2. Electrical Requirements
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
WARNING
efore assembling your ceiling fan, refer to section on
B proper method of wiring your fan (page 12). If you feel you do no t h a ve enou g h w i ring kn o w l e dge or experience, have your fan installed by a licensed electrician.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
!
WARNING
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not accept a b l e f o r fan suppor t a n d may need to be replaced. Consult a qualified electrician if in doubt.
WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly groun d e d a s a precaution against possible electrical shock.
!
!
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
WARNING
To avoid fire or shock, follow all wiring instructions carefully.
Any elect r i c al work not de s c r ibed in the s e instructions should be done or approved by a licensed electrician.
Plea s e c all Eme r son te c hnic a l s upp o rt a t 1-800-654-3545 if you have any q uestions about installation and operation of this ceiling fan.
!
E.T.L. Model No.: CF610
4
3. Ceiling Fan Assembly
BOTTOM FOAM PAD
FAN ASSEMBLY
FAN ASSEMBLY
SHIPPING SPACER
SHIPPING SPACER SCREW
3.1
Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install
he ceiling fan mounting plate on the outlet box.
t
3.2
Remo v e the f a n ass e mbly f rom th e prot e ctiv e plastic bag. Place the fan assembly into the bottom foam pad with the bottom of the fan assembly motor facing up (Figure 1).
The bottom foam pad serves as a holder for the fan during the first stages of assembly.
Turning off wall switch is not sufficient. To avoid
ossible electrical shock, be sure electricity is turned
p off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly groun d e d a s a precaution against possible electrical shock.
!
WARNING
3.3
Remo v e th e sh i ppin g spa c ers a nd t he s p acer attachment screws from the motor before installation of blade assemblies (Figure 2).
Discard the spacers and spacer screws.
Figure 1
Figure 2
emersonfans.com
Please contact 1-800-654-3545 for further assistance
5
E.T.L. Model No.: CF610
3. Ceiling Fan Assembly (Continued)
1/4-20 x 1/2" ROUND HEAD SCREW WITH LOCKWASHER (2 per blade assembly)
BLADE/FLANGE ASSEMBLY (5)
REMOVE ONE #8-32 x 5/16" ROUND HEAD SCREW
OR
FAN BLADE
BLADE FLANGE
#10-32 x 5/16" WASHER HEAD SCREW (3)
3.4
Mount the blade flange to the fan blade using three #10- 3 2 x 5/16 ” w ashe r h ead sc r ews (sup p lie d )
Figure 3).
(
Repeat this procedure for other four fan blades and blade flanges.
WARNING
To reduce the risk of personal injury, do not bend the blade fl a n g e when ins t a l ling the b l a d e f lange s , balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades
!
3.5
Attach one blade assembly to the motor hub using two 1/4-20 x 1/2” round head screws with lockwashers in flange. Make sure the screws are NOT tightened. (Figure 4.)
Repe a t this pr oced u re for t h e othe r f our bl a de assemblies.
NOTE: The blade flanges have an interlocking feat u re t h at m u st b e ful l y en g age d bef o re tightening the screws. Make sure all the flanges are pr o p e r l y engaged and then tighten the flange screws. If one of the flanges does not seat properly on t h e m o t o r h u b , l o o s e n t h e adjacent flange screws, re-engage and reseat the flanges, then tighten the screws again.
Figure 3
Figure 4
3.6
Remove one of the three #8-32 x 5/16” round head screws from the fan motor assembly (Figure 5). Retain the screw for future installation.
Loosen the other two screws several turns.
Pass the fan motor assembly’s black, blue and white leads through the center hole of the switch housing adapter.
Position the switch housing adapter on the motor assembly and align the holes in the switch housing adapter with the screws on the adapter.
NOTE: Do not pinch wires between the switch housing assembly and the switch housing adapter.
Spare #8-32 x 5/16” round head screw is provided in parts bag if needed.
E.T.L. Model No.: CF610
Figure 5
6
SWITCH HOUSING #8-32 x 5/16" FLAT HEAD SCREW (3)
SWITCH HOUSING ASSEMBLY
3. Ceiling Fan Assembly (Continued)
SWITCH HOUSING ASSEMBLY
SWITCH HOUSING ASSEMBLY CONNECTOR
FAN MOTOR CONNECTOR
REPLACE ONE #8-32 x 5/16" ROUND HEAD SCREW
FAN MOTOR ASSEMBLY
TCH
ADAPTER
ROTATE SWITCH HOUSING ADAPTER CLOCKWISE TO SECURE
3.7
otate the switch housing adapter on the fan motor
R assembly by engaging the keyhole slots of the switch housing adapter with the loosened screw heads on the fan motor assembly (Figure 6).
With the switch housing adapter locked into position, tighten the two previously loosened screws.
Rein s tal l the #8 -32 x 5/1 6 ” ro u nd h ead s crew (previously removed in Step 3.6) to secure the switch housing adapter (Figure 6).
3.8
Remove the three #8-32 x 5/16” flat head screws (Figure 7) from the switch housing assembly.
Retain the screws for future use in Step 3.10.
Figure 6
Spare #8-32 x 5/16” flat head screw is provided in parts bag if needed.
NOTE: If you are using an Emerson light fixture with your fan. Remove the screw plug from the bottom of the switch housing cover and install the lig h t i n a c c o r d a n c e w i t h t h e l i g h t k i t O w n e r ' s Manual. Make light kit electrical connections to blue and white leads marked “For Light” in the switch housing assembly. Follow light kit instructions for wiring a n d install a t ion. The n r einstal l s witch housing as outlined above.
3.9
Engage the connector of the switch housing assembly with the fan motor connector (Figure 8).
The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connector latch closes properly.
Figure 7
Figure 8
emersonfans.com
Please contact 1-800-654-3545 for further assistance
7
E.T.L. Model No.: CF610
SETSCREW (LOOSENED)
HANGER BALL
4.5" DOWNROD
PIN
GREEN GROUND WIRE
3. Ceiling Fan Assembly (Continued)
SWITCH HOUSING ASSEMBLY
R
EINSTALL SWITCH HOUSING #8-32 x 5/16"
FLAT HEAD SCREW (3)
3.10
osition the switch housing assembly on the switch
P housing adapter and align the holes in the switch housing assembly with the holes in the adapter.
Secure the switch housing assembly by reinstalling the three #8-32 x 5/16” flat head screws (previously removed in Step 3.8) (Figure 9).
NO TE: Do not pin c h wires betwe en the switch housing assembly and the switch housing adapter.
Figure 9
3.11
Carefully turn partially assembled fan upside down and place in styrofoam carton, in preparation for final installation.
Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 10).
Remove the pin from the downrod, then remove the hanger ball.
Retain the pin and hanger ball for reinstallation in Step 3.17.
NOTE: Do not loosen the screw holding the green ground wire.