Emerson SiteLink-2E, SiteLink-4E, SiteLink-12E User Manual

SITELINK-E
Product Specification/Installation Sheet

Description

The Liebert SiteLink-E is a product platform that comes in three models: SiteLink-12E, -4E and -2E. The models differ only in the number of Emerson family ports at the bottom of the module.
SiteLink-E supports Emerson interfaces as a BACnet router that provides the communications link between Liebert units and other protocols and modules.
The SiteLink-E is designed to communicate with Liebert equipment— environmental units, UPSs and Power Distribution Units—and route the information over a BACnet, Modbus or LONWorks™ network to a Building Automation System (BAS) workstation.

Module Dimensions and Layout

Diagnostic LED indicators
Ethernet port
BACnet port
Rnet port
Local access port
Xnet remote expansion port
10/100 BaseT Ethernet Port
100 LAN LINK
BACnet
Over ARCNET156 KBaud
BT485
Net +
Net -
ARCNET
Shield
Gnd Rnet + Rnet -
Rnet
+12V
Xnet +
Xnet
Xnet -
Remote
Expansion
Gnd
Port 1 Port 2 Port 3 Port 4 Port 5 Port 6 Port 7 Port 8 Port 9 Port 10 Port 11 Port 12
Net-
Net+
Net+
®
Net-
Module
Error Codes
Chase = OK 0 = Download required
1 = Control Program Error
2 = RAM full
3 = Comm setup error
4 = System error
8 = Formatting
Blinking Dot = 'Run'
Local Access
Net-
Net+
Net+
Status
Net-
Format
Net-
Net+
11. 3"
(287mm)
3V Lithium Battery
On
Off
Enhanced Access
on Rnet
CR-123A
Assigned
Default
IP Addr
+100
Address
0
10's 1's
Address
SiteLink-12E
Net-
Net-
Net+
Net-
Net+
Net+
Module
Enable
Disable
Net+
SiteLink-12E
Power connector
ARCNET Transmit ARCNET Receive
Archive Valid Port S1 Transmit Port S1 Receive
Battery low
Enable
Disable
PTP
MSTP
on S1
on S1
485-4w 485-2w
Port 9-12
EIA-485
EIA-232
Net-
Net-
Net+
Net+
Net-Rx
Net-Rx
Net+Rx
Net+Rx
2 wire 4 wire
EIA-232
EIA-485
Net-
Net+
Net+, Net-, Net+Rx, Net-Rx
Tx, Rx, Gnd, Gnd
Net-
Net+
Net-Rx
Net+Rx
24Vac, 24VA, 1A, 50-60 Hz
26Vdc, 10W, 0.4A
Port S1
Signal Ground
Rx -
n/c
Rx +n/c
Tx -
Tx +
Net-
Net-Rx
Net+Rx
Power
On Off
Ext. Batt.
Int. Batt.
EIA-232
DCD
DTR
Rx
Tx
External
Battery
Ground
24ac/26dc
Gnd +3V
BT485
0.23"
(5.8mm)
(25.4mm)
(190.5mm)
5.5"
(139.7mm)
(25.4mm)
1"
7.5"
1"
Port S1
1

Enclosure Mounting

The enclosure may be mounted on a wall or on the floor. Refer to the following diagrams for your application.

Enclosure Mounting Diagrams

1"
(25.4mm)
11"
(279.4mm)
0.88"
(22.2mm)
12.5"
(317.5mm)
0.88"
(22.2mm)
A
1"
(25.4mm)
11"
(279.4mm)
1"
(25.4mm)
0.88"
(22.2mm)
12.5"
(317.5mm)
2
DETAIL A
0.107"
R
(2.71mm)
0.4"
(10.2mm)
0.188"
R
(4.76mm)
1"
(25.4mm)
0.88"
(22.2mm)

Enclosure Mounting Diagrams (continued)

14.25"
(362mm)
12"
(304.8mm)
1.13"
(28.6mm)
3.35"
(85mm)
1.25"
(31.8mm)
1.5"
(38.1mm)
B
1.5"
(38.1mm)
5.88"
(149.2mm)
1.5"
(38.1mm)
5.25"
(133.4mm)
2.5"
(63.5mm)
1.5"
(38.1mm)
(149.2mm)
1.5"
(38.1mm)
5.88"
1.5"
(38.1mm)
3.92"
(99.6mm)
1.15"
(29.3mm)
(15.1mm)
0.88"
(22.2mm)
DETAIL B
0.6"
3

Specifications

Power 24VAC ±10%, 50 to 60Hz, 24VA, or 26VDC ±10%, 10W, 48VDC
Dimensions W x D x H: in. (mm)
Communication Ports
• Ethernet Port 10/100Base-T Fast Ethernet port.
• ARC156 Port
• TPI Port S1
EIA-422/485 Ports 1-12 - for
communication with equipment via software-selectable protocols & baud rates
Environmental Operating Range
Memory 16 MByte non-volatile battery-backed SDRAM and 8 MByte Flash
Protection
Battery 3V lithium battery P/N CR-123A; battery shelf life is 10 years with 720 hours of continuous operation
Fault Detection Hardware watchdog timer
Agency Listings UL, cUL, CE, FCC
Module: 11.3 x 0.56 x 7.5 (287 x 14.2 x 190.5) Enclosure (brushed aluminum): 14.25 x 2.85 x 12 (362 x 72.4 x 304.8)
ARCNET156 or EIA-485 communication. In ARCNET156 mode, the port communicates via BACnet ARC156.
EIA-232/422/485 configurable port for interaction with 3rd-party building automation systems via software-selectable protocols. May also be configured for remote modem access.
Each port can be individually set for different protocols & baud rates. The number of ports varies by model:
SiteLink-2E (SSW-2E) SiteLink-4E (SSW-4E) SiteLink-12E (SSW-12E)
Ports 11-12 These two ports include an option for EIA-232 connection.
20°F to 140°F (-29°C to 60°C); 10 to 90% relative humidity, non-condensing Note: Control modules should be installed within the building.
Built-in surge and transient protection circuitry - internal solid state polyswitches on incoming power and network communications connections
Ports 9-12 These four ports include an option for EIA-232 connection.
Ports 1-12 Four of these 12 ports (9-12) include an option for EIA-232 connection.

Wiring Specifications

Connection Supported Wire Types Maximum Wire Length Rating
Ethernet 10 BaseT CAT 5 328 ft. (100m) N/A
BACnet Port MAGNUM Cable P/N A3-ARC-156-2 3000 ft. (915m) N/A
Port S1 EIA-485
Port S1 EIA-232
18-22 AWG Stranded & Shielded; 18 AWG (recommended) Non Plenum - Belden 9461; Plenum - Belden 88761
18-22 AWG Stranded & Shielded; 18 AWG (recommended) Non Plenum - Belden 9461; Plenum - Belden 88761
1000 ft. (300m) N/A
50 ft. (15m) N/A

Ordering Information

Quantity Part # Description
SSW-12E SiteLink-12E with enclosure - communicates with up to 12 Liebert unit controllers
SSW-12EWO SiteLink-12E without enclosure - communicates with up to 12 Liebert unit controllers
SSW-4E SiteLink-4E with enclosure - communicates with up to 4 Liebert unit controllers
SSW-4EWO SiteLink-4E without enclosure - communicates with up to 4 Liebert unit controllers
SSW-2E SiteLink-2E with enclosure - communicates with up to 2 Liebert unit controllers
SSW-2EWO SiteLink-2E without enclosure - communicates with up to 2 Liebert unit controllers
Liebert Corporation
1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229
Telephone: 1-800-877-9222 Facsimile: 1-614-841-6022 www.liebert.com
© 2007 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice.
® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners.
SL-27218_REV0_01-07
4
Loading...