Emerson Rosemount 975 Communications Manual

Rosemount™ 975 Flame Detector
HART® Communication Manual
Reference Manual
00809-0200-4975, Rev A
June 2017
Reference Manual
0809-0200-4975, Rev A
Contents
1Section 1: Introduction
2Section 2: Product Overview
3Section 3: HART Interconnection
Contents
June 2017
1.1 Using this manual. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Product recycling/disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.3 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.4 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.5 Reference documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.1 Rosemount 975 Flame Detector Product Overview . . . . . . . . . . . . . . . . . . . . . . . . 3
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.2 Point-to-point mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3.3 Multidrop mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4Section 4: HART Device Description Language
4.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.2 HART protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5Section 5: HART Menu Structure
5.1 HART menu overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2 Root menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
5.3 Status menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.4 Device setup menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.5 HART output menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5.6 HART status menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
AAppendix A: Field Device Status
A.1 Field Device Status Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Contents
i
Contents
June 2017
Reference Manual
FGD-MAN-928-Wireless-Gas Monitor, Rev A
ii
Contents
Reference Manual
00809-0200-4975, Rev A

Section 1 Introduction

1.1 Using this manual

The sections in this manual provide information on installing, operating, and maintaining the Rosemount
Section 2: Product Overview provides a high-level description of the Rosemount 975 Flame Detector.
Section 3: HART Interconnection contains information on the connection modes used to connect HART
Communication with the Rosemount 975 Flame Detector.
Section 4: HART Device Description Language describes the HART Device Description Language format
used to configure the Rosemount 975 Flame Detector.
Section 5: HART Menu Structure provides HART menu , submenu, and command information.
Appendix A: Field Device Status contains field device status information.
975 Flame Detector. The sections are organized as follows:
Introduction
June 2017

1.2 Product recycling/disposal

Recycling of equipment and packaging should be taken into consideration and disposed of in accordance with local and national legislation/regulations.

1.3 Scope

Digital communication with the Rosemount 975 Flame Detector allows the operator to monitor the status of the detector, determine factory settings and initiate field tests.
This document provides guidance for establishing HART communication and structure when using the Rosemount 975 Flame Detector with a HART Handheld computer, or another process interface device that supports Device Description Language (DDL).

1.4 Purpose

This manual is designed for use by system integrators and end users to compliment other documentation (for example, the user manual for your Rosemount 975 Flame Detector) by providing a complete, unambiguous description of the HART Host Application and Communication.

1.5 Reference documents

describe the HART menu
Communicator,
Introduction
HART Field Communications Protocol Specification, HCF_SPEC-12, Available from the HCF.
1
Introduction
June 2017
Reference Manual
00809-0200-4975, Rev A
2
Introduction
Reference Manual
00809-0200-4975, Rev A
Product Overview
June 2017

Section 2 Product Overview

Rosemount 975 Flame Detector Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3

2.1 Rosemount 975 Flame Detector Product Overview

The Rosemount 975 Series Flame Detectors are a family of Flame Detectors that incorporate advanced optical spectral analysis of flames. Rosemount 975 Flame Detectors operate reliably in the harsh conditions of offshore drilling and production platforms, FPSO vessels, fuel loading facilities, LNG and LPG plants, oil refineries, aircraft hangars, paint spray booths, gas turbine power stations, chemical and petrochemical plants.
Rosemount 975 Flame Detectors employ the latest UV/IR (Ultra Violet & Infrared), and IR3 (Triple IR patented multi-spectrum detection) Flame Detection technologies.
Depending on the specific model, the Rosemount 975 Flame Detector may include the following interfaces: 4-20mA current output, HART communication, relays, RS485 ModBus communication, status LEDs.
Product Overview
3