This guide provides basic guidelines for Rosemount 0068, 0078, and 0183 Sensor models. It does not provide
instructions for configuration, diagnostics, maintenance, service, troubleshooting, explosion-proof,
flameproof, or intrinsically safe (I.S.) installations.
If the Rosemount Volume 1 Sensor was ordered assembled to a temperature transmitter, see the appropriate
transmitter Quick Start Guide for information on configuration and hazardous locations certifications.
1.0Wiring diagrams
Figure 1. Rosemount Series 68, 68Q, 78, and 58C RTD Wire Colors
Single elementDual element
(1)
A
B
B
A
A
C
C
B
B
A. Red
B. White
C. Green
D. Black
1. Dual element sensors are only available on Rosemount Series 68Q and 78 Sensors.
Note
For three-wire systems, use one white and two red leads. Do not connect the white leads.
Insulate or terminate the unused white lead in a manner that prevents shorting to the
ground. For two-wire systems, connect both sets of leads.
1. Determine the length to which the sheath will be cut. The finished length
needs to include an additional 1.5-in. for compression fittings, or 2.5-in, for
spring-loaded fittings (see Figure 2).
2. Remove and save the heat shrink tubing from the rear of the sensor.
3. Place the sensor in a vise, taking care not to overtighten, and position the
tubing cutter on the sheath.
4. Score the sheath to a depth of approximately
the lead wire insulation, do not cut completely through the sheath.
5. Firmly grasp the end of the sheath with your hand or a pair of pliers. Using a
sharp snapping motion, break off and remove the excess sheath material.
Take care not to strip or damage the lead wire insulation while removing the
excess sheath material.
Note
If you are unable to easily break off excess sheath material, deepen the score and repeat
Step 5.
6. Replace the heat shrink tubing.
1
/64-in. To prevent damage to
3.0Drawings
Quick Start Guide
Figure 2. Rosemount Series 58C Sensor
A. Four lead wires 6 (152) long
B. X length ±0.25 (±6)
C. 0.25 ±0.002 (6.35 ±0.13) diameter
D. Heat shrink tubing
E. Do not cut or bend sheath within 2 (51)
F. 0.6 (15) max. sensing element
3
Quick Start Guide
+ A
- B
+ C
- B
+ D
- B
+ E
- B
Figure 3. Rosemount Series 183 Thermocouple Wire Colors
Typ e JTyp e E
Typ e KTyp e T
A. White
B. Red
C. Purple
D. Yellow
E. Blue
Table 1. Rosemount Series 183 Thermocouple Characteristics
Thermocouple
typ es
JIron/constantan0 to 76032 to 1400
KChromel®/Alumel®0 to 1150 32 to 2102
E
T
Thermocouple
wire alloys
Chromel/
constant an
Copper/
constant an
Temperature range
°C°F
0 to 87132 to 1600
–180 to 0 –292 to 32
0 to 37132 to 700
Limits of error (interchangeability)
±1.1 °C (2.0 °F) or ±0.4% of measured
temperature, whichever is greater
±1.1 °C (2.0 °F) or ±0.4% of measured
temperature, whichever is greater
±1.0 °C (1.8 °F) or ±0.4% of measured
temperature, whichever is greater
±1.0 °C (1.8 °F) or ±1.5% of measured
temperature, whichever is greater
±0.5 °C (1.0 °F) or ±0.4% of measured
temperature, whichever is greater
April 2019
Note
To distinguish the two sensors in dual Rosemount 183 Sensors, there is an outer insulation
wrapped around each pair of sensor wires.
4
April 2019
A
B
D
C
E
F
I
G
H
K
J
L
M
O
N
P
Q
R
S
T
Figure 4. Sensor Assembly
Quick Start Guide
A. Open identification tag
B. Standard adapter sensor assembly
C. Sensor immersion length “X”
D. 0.5-in. (13 mm) nominal engagement
E. Coupling-nipple
F. Extension length
G. Overall thermowell length
H. Lead wire extensions and seals
I. 0.5-in. (13 mm) nominal engagement
J. Extensions
K. Union-nipple
Note
Sensor assemblies can be provided without an enclosure or with an enclosure such as the
connection heads shown above or assembled to a Rosemount transmitter.
L. Fla t or extended cover aluminum
connection heads
M. Threaded Thermowell
N. Thermowells
O. T + 1.75-in. (44.5 mm)
P. Socket weld thermowell
Q. Polypropylene connection head
R. Thermowell immersion length
S. Flanged thermowell
T. Rosemount aluminum connection head
5
Quick Start Guide
4.0Product certifications
Rev 2.10
4.1European Directive Information
A copy of the EU Declaration of Conformity can be found at the end of the Quick
Start Guide. The most recent revision of the EU Declaration of Conformity can
be found at Emerson.com/Rosemount
4.2Ordinary Location Certification
As standard, the transmitter has been examined and tested to determine that
the design meets the basic electrical, mechanical, and fire protection
requirements by a nationally recognized test laboratory (NRTL) as accredited by
the Federal Occupational Safety and Health Administration (OSHA).
4.3North America
The US National Electrical Code® (NEC) and the Canadian Electrical Code (CEC)
permit the use of Division marked equipment in Zones and Zone marked
equipment in Divisions. The markings must be suitable for the area
classification, gas, and temperature class. This information is clearly defined in
the respective codes
North America
E5 FM Explosion proof, Dust-Ignition proof
Certificate: FM17US0170X
Standards: FM Class 3600: 2011; FM Class 3611: 2004; FM Class 3615: 2006; FM Class
3810: 2005; ANSI/NEMA
Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G;
Markings: XP CL I, Div 1, GP B, C, D; DIP CL II/III, Div 1, GP E, F, G; CL I, Div 2, GP A, B, C,
D; (–50 °C ≤ T
00068-0033; Type 4X (Spring loaded sensors must be installed in a
thermowell to maintain Type 4X and Cl. II/III rating)
≤ 85 °C); when installed per Rosemount drawing
a
Europe
E1 ATEX Flameproof
Certificate: FM12ATEX0065X
Standards: EN 60079-0: 2012+A11:2013, EN 60079-1: 2014, EN 60529:1991
+A1:2000 +A2:2013
Markings: II 2 G Ex db IIC T6…T1 Gb, T6(–50 °C ≤ T
+60 °C)
6
≤ +40 °C), T5…T1(–50 °C ≤ Ta ≤
a
April 2019
Quick Start Guide
Specific Conditions of Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of
ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than 4 joules.
4. Flameproof joints are not intended for repair.
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature
probes with Enclosure option "N".
6. Care shall be taken by the end user to ensure that the external surface temperature on
the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
7. Non-Standard Paint options may cause risk from electrostatic discharge. Avoid
installations that cause electrostatic build-up on painted surfaces, and only clean the
painted surfaces with a damp cloth. If paint is ordered through a special option code,
contact the manufacturer for more information.
International
E7 IECEx Flameproof
Certificate: IECEx FMG 12.0022X
Standards: IEC 60079-0:2011, 60079-1:2014-06
Markings: Ex db IIC T6…T1 Gb, T6(–50 °C ≤ T
+60 °C)
Specific Conditions of Use (X):
1. See certificate for ambient temperature range.
2. The non-metallic label may store an electrostatic charge and become a source of
ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than 4 joules.
4. Flameproof joints are not intended for repair
5. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature
probes with Enclosure option "N".
6. Care shall be taken by the end user to ensure that the external surface temperature on
the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
7. Non-Standard Paint options may cause risk from electrostatic discharge.
2. The non-metallic label may store an electrostatic charge and become a source of
ignition in Group III environments.
3. Guard the LCD display cover against impact energies greater than 4 joules.
4. A suitable certified Ex d or Ex tb enclosure is required to be connected to temperature
probes with Enclosure option "N".
5. Care shall be taken by the end user to ensure that the external surface temperature on
the equipment and the neck of DIN Style Sensor probe does not exceed 130 °C.
6. Consult the manufacturer if dimensional information on the flameproof joints is
necessary.
≤ +40 °C), T5…T1: (–50 °C ≤ Ta ≤
a
≤ +70°C )
a
7
Quick Start Guide
EAC
EM Technical Regulations Customs Union (EAC) Flameproof
Certificate: RU C-US.Gb05.B.00289
Markings: 1Ex d IIC T6…T1 Gb X
Korea
EP Korea Explosionproof/Flameproof
Certificate: 13-KB4BO-0560X
Markings: Ex d IIC T6…T1; T6(–50 °C ≤ T
Special Condition for Safe Use (X):
1. See certificate.
Combinations
KF Combination of E1 and E6
KD Combination of E5, E6, and E1
+60 °C)
≤ +40 °C), T5…T1(–50 °C ≤ T
amb
April 2019
≤
amb
8
April 2019
(signature)
(function)
(name)
(date of issue)
Quick Start Guide
Figure 5. Rosemount Series 68, 68Q, 78, and 58C Declaration of Conformity
EU Declaration of Conformity
No: RMD 1059 Rev. P
We,
Rosemount, Inc.
8200 Market Boulevard
Chanhassen, MN 55317-9685
USA
declare under our sole responsibility that the product,
Rosemount™ Model 65, 68, 78, 85, 183, 185, and 1067
manufactured by,
Rosemount, Inc.
8200 Market Boulevard
Chanhassen, MN 55317-9685
USA
to which this declaration relates, is in conformity with the provisions of the European Union
Directives, including the latest amendments, as shown in the attached schedule.
Assumption of conformity is based on the application of the harmonized standards and, when
applicable or required, a European Union notified body certification, as shown in the attached
schedule.
Temperature Sensors
Chris LaPoint
Page 1 of 2
Vice President of Global Quality
1-April-19
9
Quick Start Guide
EU Declaration of Conformity
No: RMD 1059 Rev. P
Page 2 of 2
ATEX Directive (2014/34/EU)
FM12ATEX0065X - Flameproof Certificate
Equipment Group II Category 2 G (Ex db IIC T6…T1 Gb)
Harmonized Standards:
EN60079-0:2012+A11:2013, EN60079-1:2014
FM12ATEX0065X - Dust Certificate
Equipment Group II Category 2 D (Ex tb IIIC T130°C Db)
Harmonized Standards:
EN60079-0:2012+A11:2013, EN60079-31:2014
BAS00ATEX3145 - Type n Certificate
Equipment Group II Category 3 G (Ex nA IIC T5 Gc)
Harmonized Standards:
EN60079-0:2012+A11:2013, EN60079-15:2010
Baseefa16ATEX0101X - Intrinsic Safety Certificate
Equipment Group II Category 1 G (Ex ia IIC T5/T6 Ga)
Harmonized Standards:
EN60079-0:2012+A11:2013, EN60079-11:2012
RoHS Directive (2011/65/EU)
Harmonized Standard: EN 50581:2012
ATEX Notified Bodies
FM Approvals Europe Limited [Notified Body Number: 2809]
One Georges Quay Plaza
Dublin, Ireland. D02 E440
SGS FIMCO OY [Notified Body Number: 0598]
P.O. Box 30 (Särkiniementie 3)
00211 HELSINKI
Finland
ATEX Notified Body for Quality Assurance
SGS FIMCO OY [Notified Body Number: 0598]
P.O. Box 30 (Särkiniementie 3)
00211 HELSINKI
Finland
April 2019
10
April 2019
ᴹ
㇑᧗⢙䍘䎵䗷ᴰབྷ⎃ᓖ䲀٬Ⲵ䜘Ԧරࡇ㺘
䜘Ԧ〠
Part Name
ᴹᇣ⢙䍘䍘Hazardous Substances
䫵
Lead
(Pb)
⊎
Mercury
(Hg)
䭹
Cadmium
(Cd)
ޝԧ䬜䬜
Hexavalent
Chromium
(Cr +6)
ཊⓤ㚄㚄㤟
Polybrominated
biphenyls
(PBB)
ཊⓤ㚄㚄㤟䟊
Polybrominated
diphenyl ethers
(PBDE)
⭥ᆀ㓴Ԧ
Electronics
Assembly
O O O O O
O
༣փ㓴Ԧ
Housing
Assembly
O O O O O
O
Րᝏಘ㓴Ԧ
Sensor
Assembly
O O O O O
O
Quick Start Guide
China RoHS
List of Rosemount 68/78/183 Parts with China RoHS Concentration above MCVs
ᵜ㺘Ṭ㌫ᦞ
This table is proposed in accordance with the provision of SJ/T11364.
Ѫ䈕䜘ԦⲴᡰᴹ൷䍘ᶀᯉѝ䈕ᴹᇣ⢙䍘Ⲵ䟿൷վҾ
O:
O: Indicate that said hazardous substance in all of the homogeneous materials for this part is below the limit requirement of
GB/T 26572.
Ѫ൘䈕䜘Ԧᡰ֯⭘Ⲵᡰᴹ൷䍘ᶀᯉ䟼ˈ㠣ቁᴹа㊫൷䍘ᶀᯉѝ䈕ᴹᇣ⢙䍘Ⲵ䟿儈Ҿ
X:
X: Indicate that said hazardous substance contained in at least one of the homogeneous materials used for this part is above
the limit requirement of GB/T 26572.