Emerson Rosemount 5400 Quick Start Manual

Page 1
Quick Start Guide
00825-0600-4026, Rev AA
March 2016
Rosemount™ 5400 Level Transmitter
Mounting Instructions for Parabolic Antenna
Page 2
March 2016
2
Quick Start Guide
1.0 About this guide
This Quick Start Guide provides mechanical installation instructions for the Rosemount 5402 Level Transmitter with parabolic antenna.
For information about electrical installation and configuration, refer to the Rosemount 5400 Series Quick Start Guide (document number 00825-0100-4026).
Failure to follow safe installation and service guidelines could result in death or serious injury.
Make sure the transmitter is installed by qualified personnel and in accordance with applicable code of
practice.
Use the equipment only as specified in this Quick Start Guide and the Reference Manual. Failure to do so
may impair the protection provided by the equipment.
Any substitution of non-authorized parts or repair, other than exchanging the complete transmitter head
or antenna assembly, may jeopardize safety and is prohibited.
Explosions could result in death or serious injury.
Verify that the operating environment of the transmitter is consistent with the appropriate hazardous
locations specifications.
To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. Before connecting a Field Communicator in an explosive atmosphere, make sure the instruments in the
loop are installed in accordance with intrinsically safe or non-incendive field wiring practices.
To avoid process leaks, only use O-rings designed to seal with the corresponding flange adapter.Do not remove the transmitter while in operation.
Electrical shock can result in death or serious injury.
Avoid contact with the leads and terminals. High voltage that may be present on leads can cause electrical
shock.
Make sure the main power to the Rosemount 5400 Level Transmitter is off and the lines to any other
external power source are disconnected or not powered while wiring the transmitter.
Ground device on non-metallic tanks (e.g. fiberglass tanks) to prevent electrostatic charge build-up.
Contents
Parabolic antenna overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3
Mount the flanged version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
Mount the welded version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6
Mount the threaded version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
Adjust inclination of antenna . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 19
Page 3
Quick Start Guide
3
March 2016
2.0 Parabolic antenna overview
Flanged version
Welded version
Threaded version
page 4-5
page 6-12
page 13-18
Page 4
March 2016
4
Quick Start Guide
3.0 Mount the flanged version
Step 1: Mount antenna assembly on tank
Step 2: Adjust inclination of antenna
Refer to section “Adjust inclination of antenna” on page 19 for further information.
Gasket
Page 5
Quick Start Guide
5
March 2016
Step 3: Tighten blind plug or install air purging system
Proceed with electrical installation. For further instructions, see the Rosemount 5400 Series Quick Start Guide (document number 00825-0100-4026).
G3/8"
Air purging?No Yes
0.3-0.4 in. (8-10 mm)
(gasket excluded)
Torque 180 in-lb (20 Nm)
Use thread sealant or
gasket according to
your site procedures.
Page 6
March 2016
6
Quick Start Guide
4.0 Mount the welded version
Figure 1. Components
A. B. C. D. E.
Weld protection plate Weld protection bar Flange ball O-ring Clamp flange
F. G. H. I. J.
Washer M8 screw Antenna Ball joint Threaded sleeve
K. L. M.
M20 adapter G3/8" bonded seal Blind plug
2x 1x 1x
1x
1x
1x 1x
1x
1x
3x 3x
A
B
C
D
E
F
G
I
H
1x
K
1x
J
L
M
Page 7
Quick Start Guide
7
March 2016
Step 1: Mount protection plates to flange/manhole cover
These plates protects the internal surfaces of the flange ball from welding sparks.
Ø 3.94 ± 0.02 in.
(Ø 100 ± 0.5 mm)
A
C
B
A
Max. 1.18 in. (30 mm)
Page 8
March 2016
8
Quick Start Guide
Step 2: Weld flange ball
Step 3: Remove protection plates
Visually inspect the internal surfaces of the flange ball for damage and dirt.
Step 4: Mount O-ring
D
Page 9
Quick Start Guide
9
March 2016
Step 5: Mount ball joint
Gradually tighten the M8 nuts.
Step 6: Remove protection cap
Visually inspect the O-rings for damage and dirt.
M8
Torque 90 in-lb (10 Nm)
F
G
E
I
O-rings
H
Page 10
March 2016
10
Quick Start Guide
Step 7: Carefully insert antenna
Step 8: Secure antenna
J
K
Torque 180 in-lb (20 Nm)
Page 11
Quick Start Guide
11
March 2016
Step 9: Tighten set screw
Step 10: Mount antenna assembly on tank
Step 11: Adjust inclination of antenna
Refer to section “Adjust inclination of antenna” on page 19 for further information.
M4
Torque 5 in-lb (0.5 Nm)
Gasket
Page 12
March 2016
12
Quick Start Guide
Step 12: Tighten blind plug or install air purging system
Proceed with electrical installation. For further instructions, see the Rosemount 5400 Series Quick Start Guide (document number 00825-0100-4026).
G3/8"
Air purging?No Yes
0.3-0.4 in. (8-10 mm)
(gasket excluded)
Torque 180 in-lb (20 Nm)
Use thread sealant or
gasket according to
your site procedures.
L
M
Page 13
Quick Start Guide
13
March 2016
5.0 Mount the threaded version
Figure 2. Components
A. B. C.
Lock nut Antenna adapter with ball joint O-ring
D. E. F.
Antenna Threaded sleeve M20 adapter
G.H.G3/8" bonded seal
Blind plug
2x
1x 1x
1x
1x
1x 1x
A
B
C
D
1x
F
1x
E
G
H
Page 14
March 2016
14
Quick Start Guide
Step 1: Remove lock nut
Step 2: Mount O-ring
A
B
C
Page 15
Quick Start Guide
15
March 2016
Step 3: Mount antenna adapter on flange/manhole cover
Make sure the antenna adapter fits tightly to the flange/manhole cover.
Step 4: Remove protection cap
Visually inspect the O-rings for damage and dirt.
Ø 3.98 ± 0.02 in.
(Ø 101 ± 0.6 mm)
OR
G3½"
Max. 1.18 in. (30 mm)
> 0.59 in. (15 mm)
O-rings
D
Page 16
March 2016
16
Quick Start Guide
Step 5: Carefully insert antenna
Step 6: Secure antenna
E
F
Torque 180 in-lb (20 Nm)
Page 17
Quick Start Guide
17
March 2016
Step 7: Tighten set screw
Step 8: Mount antenna assembly on tank
M4
Torq u e 5 in-lb (0.5 Nm)
Gasket
Page 18
March 2016
18
Quick Start Guide
Step 9: Adjust inclination of antenna
Refer to section “Adjust inclination of antenna” on page 19 for further information.
Step 10: Tighten blind plug or install air purging system
Proceed with electrical installation. For further instructions, see the Rosemount 5400 Series Quick Start Guide (document number 00825-0100-4026).
G3/8"
Air purging?No Yes
0.3-0.4 in. (8-10 mm)
(gasket excluded)
Torque 180 in-lb (20 Nm)
Use thread sealant or
gasket according to
your site procedures.
G
H
Page 19
Quick Start Guide
19
March 2016
6.0 Adjust inclination of antenna
6.1 Orientation
General best practice is to initially align the parabolic antenna vertically to the
ground.
If the surface echo is weak, a small inclination of the antenna toward the
surface slope may improve the performance.
The angle of slope differs during filling and emptying, and thus the signal strength. Therefore, monitor the entire cycle to verify optimum antenna inclination.
90°
Page 20
March 2016
20
Quick Start Guide
6.2 Procedure
Step 1: Remove transmitter housing (if applicable)
Step 2: Loosen M8 screws until antenna can tilt smoothly
Contents may be under pressure
Do not loosen the M8 screws while in operation.
Attempting to do so may release pressurized gases, resulting in serious injury or death.
Page 21
March 2016
21
Quick Start Guide
Step 3: Place circular level on top of antenna assembly
Step 4: Adjust inclination of antenna
Page 22
March 2016
22
Quick Start Guide
Step 5: Gradually tighten M8 screws
Step 6: Remove circular level
M8
Torque 90 in-lb (10 Nm)
Page 23
Quick Start Guide
23
March 2016
Step 7: Mount transmitter housing
Torque 355 in-lb (40 Nm)
Page 24
Global Headquarters
Emerson Process Management
6021 Innovation Blvd. Shakopee, MN 55379, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 [email protected]
North America Regional Office
Emerson Process Management
8200 Market Blvd. Chanhassen, MN 55317, USA
+1 800 999 9307 or +1 952 906 8888 +1 952 949 7001 [email protected]
Latin America Regional Office
Emerson Process Management
1300 Concord Terrace, Suite 400 Sunrise, FL 33323, USA
+1 954 846 5030 +1 954 846 5121 [email protected]
Linkedin.com/company/Emerson-Process-Management
Twitter.com/Rosemount_News
Facebook.com/Rosemount
Youtube.com/ user/RosemountMeasurement
Google.com/+RosemountMeasurement
Standard Terms and Conditions of Sale can be found at
Emerson.com/en-us/pages/Terms-of-Use.aspx
The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount and the Rosemount logotype are trademarks of Emerson Process Management. All other marks are the property of their respective owners. © 2016 Emerson Process Management. All rights reserved.
Europe Regional Office
Emerson Process Management Europe GmbH
Neuhofstrasse 19a P.O. Box 1046 CH 6340 Baar Switzerland
+41 (0) 41 768 6111 +41 (0) 41 768 6300 [email protected]
Asia Pacific Regional Office
Emerson Process Management Asia Pacific Pte Ltd
1 Pandan Crescent Singapore 128461
+65 6777 8211 +65 6777 0947
Middle East and Africa Regional Office
Emerson Process Management
Emerson FZE P.O. Box 17033, Jebel Ali Free Zone - South 2 Dubai, United Arab Emirates
+971 4 8118100 +971 4 8865465
Quick Start Guide
00825-0600-4026, Rev AA
March 2016
*00825-0600-4026*
Loading...