Emerson Keystone Installation And Maintenance Instructions Manual

KEYSTONE BUTTERFLY VALVES PARASEAL
InstallatIon and maIntenance InstructIons
Before installation these instructions must be fully read and understood
Please read these instructions carefully
Hazard potentials:
• disregarding of instructions
• improper use of product
• insufficiently qualified personnel
Valve application to be within the pressure/ temperature limits indicated in the P/T diagram.
Essential points and functions of the valve should be inspected on a regular basis.
1 STORAGE AND HANDLING
1.1 Protection
Keystone butterfly valves are delivered with protection in accordance with the Keystone Engineering Instructions, to protect the valve seats and disc from damage. Wrapping and/or covers should be left in place until immediately before fitting to the pipe.
1.2 Storage
When valves are to be stored for some time (2months or more) before being fitted, storageshould be in the original delivery cratesor cases.
1.2.1 Storage conditions
The valves should be stored off the ground inaclean, dry indoor area. Protect the valve from temperature and humidity extremes, and exposure to excessive dust, moisture, vibration, deformations, sunlight and ozone.
Recommendations
1. Temperature: storage temperature below 25°C, above 0°C preferable below 15°C.
2. Humidity: storage conditions should be such that condensation does not occur, store in a dry environment. Maximal 50% relative humidity.
3. Light: valve rubbers should be protected from light, in particular direct sunlight or strong artificial light with high ultra violet.
4. Ozone: storage rooms should not contain any equipment generating ozone. E.g.lamps, electric motors.
IMPORTANT
Before valves are being installed or used thefollowing actions are recommended.
1. Valves/parts have to be inspected and thoroughly cleaned if required.
2. Rubber parts need to be greased with silicone grease if not present anymore.
3. All surfaces in contact with seats have to be thoroughly cleaned and greased with silicone grease if stored for more than 5 months.
1.3 Handling
1.3.1 Packed valves
Lifting and handling of the packed valves in crates should be carried out by appropriate lifting equipment. If a fork lift truck is used, appropriate fork hitches are required. The lifting and handling of packed valves in cases will be carried out in the lifting points. The transportation of all packed material should be carried out safely and according thelocal safety regulations.
1.3.2 Unpacked valves
The lifting and the handling of these valves has to be carried out by using appropriate means and by respecting the carrying limits. The handling must, preferably, be carried out on pallets, protecting the machined surfaces and seat to avoid damage. When lifting the large dimension valves, the sling and the hooking of the load must be carried out by using the appropriate tools (brackets, hook, fasteners) and load balancing tools in order to prevent the valves from falling or moving during the lifting and handling. The valve may be lifted only by slings attached to the flange holes or valve body; never to the actuator or the valve opening.
Emerson.com/FinalControl
© 2017 Emerson. All Rights Reserved. VCIOM-00770-EN 17/10
KEYSTONE BUTTERFLY VALVES PARASEAL
InstallatIon and maIntenance InstructIons
2 INSTALLATION
WARNING
For safety reasons, it is important to take the following precautions before you start work on the valve:
1.
Personnel making any adjustments to the valves should utilize suitable equipment. All required personal protection means should be worn.
2. The line must be depressurized before installing the valve.
3. Personnel trained in all aspects of manual and mechanical handling techniques only must carry out handling of the valves.
4. Misuse of the valve is not allowed. For example: the valve, handles, actuators or other parts may not be used as ‘climbing tools’.
5.
Ensure that valve pressure/temperature limitations marked on the identification tag are within the service conditions. The trim number on the valve’s tagplate identifies the valve materials. See Product Manual for valve specific P/T diagram and trim number definition.
6. Ensure that valve materials are compatible with the pipeline fluid.
2.1 Valve inspection
1. Carefully remove the valve from the shipping package (box or pallet) avoiding any damage to the valve or, in case of automated valves, to the electric or pneumatic/ hydraulic actuator or instrumentation.
2. Confirm that the materials of construction listed on the valve nameplate are appropriate for the service intended and are as specified.
3. It is not allowed to use third party spare parts. In case of third party spare parts, safeoperation is not guaranteed.
2.2 Flange and pipe compatibility
Check matching of flange drilling pattern of valve and pipe flange before assembly. Flanges have to meet the following requirements:
- The face inside diameter should be: D min. : The valve Q-dimension + adequate
disc clearance.
D max.: The inside diameter (ID) of standard
pipe for the nominal size ISO4200.
For larger inside pipe diameters
contact factory.
- If the flange (or pipe) is provided with a raised face, the diameter of this shall be at least 10mm larger than the YY-dimension of the valve.
- The use of the flange gaskets is not allowed since it might damage the valve.
- The Keystone seat face design eliminates the need for the gaskets.
- Use flange bolting in agreement with appropriate standard.
Do not use flange gaskets!
2.3 Valve installation
The valves are bi-directional and may be fitted in either direction relative to the flow. The valve will control flow equally in either direction. The recommended installation position is shaft horizontal and the lower disc edge opening down-stream. (Especially for slurry service and media with a tendency for sedimentation). For optimum valve control and smooth performance, it is recommended to have a 10to 20 pipe diameters of straight run inlet piping and 3 to 5 pipe diameters straight outlet piping. A valve is no crow-bar. Do not use the valve to spread the flanges. Seat damage might be theresult.