Emerson Islatrol SP-6TVN Installation Manual

Headquarters
Islatrol® SP Series – Surge Suppressor/Filter
User Manual
Surge Protection
30 Charles Street Binghamton, NY 13905 P (607) 721-8840 P (800) 288 6169 F (607) 722 8713 E contactsurge@emerson.com
Surge Protection for Home and Office
– Islatrol® SP-6TVN and SP-6TN
IO-30112 Rev.2 11/09
SP-6TVN
SP-6TN
Congratulations on purchasing the Islatrol® SP-6TVN/SP-6TN multi-
Specifications
AC Power Protection
Phone Protection
Rated Output
15A
Modes of Protection
T-R, T-G, R-G
Peak Surge Current
39kA
Frequency Response
60dB Max
(SP-6TVN ONLY)
Connection Type
‘F’
Connection Type
RJ45
Peak Surge Current
5kA
Peak Surge Current
3kA
stage Industrial Strength Surge Suppressor with Active Tracking® Filter. These instructions will insure your Islatrol® SP-6TVN/SP-6TN surge suppressor is properly installed and functioning.
The Islatrol® SP-6TVN/SP-6TN is designed to protect 120 Volt electronics with up to 15-amp current carrying capability. grounded to work. Ensure that any duplex receptacle used for the Islatrol® SP-6TVN/SP-6TN is properly grounded.
Step 1: Connecting the Islatrol® SP-6TVN/SP-6TN to a Duplex Receptacle
Remove the duplex receptacle mounting screw. If the duplex re­ceptacle face plate is metal, remove it otherwise leave in place. Place the Islatrol® SP-6TVN/SP-6TN and the duplex receptacle face plate, (if plastic) over the duplex receptacle. Insert the blades of the Islatrol® SP-6TVN/SP-6TN into the duplex receptacle. Tighten the mounting screw.
When installed in a properly grounded receptacle, Islatrol 6TVN/SP-6TN indicator light will be operational. If the indicator
light does not illuminate, it means the wall receptacle has an incor­rect ground. Try the SP-6TVN/SP-6TN in a different wall outlet. If it still doesn’t illuminate, contact the office where you purchased your Islatrol® SP-6TVN.
You can reposition the Islatrol clearance for your power cords if needed and connect up to 15 amps of equipment load.
Step 2: Connecting your Video Electronics to the Islatrol® SP-6TVN
Disconnect the video cable going to your home entertainment
system. Check to make sure that the small center wire inside the
video connection is straight, (not bent) and then connect it to the
“IN” of one of the video suppressor connections on the Islatrol®
SP-6TVN. Open one of the jumper wires that came with the
Islatrol® SP-6TVN. Connect one end to the “OUT” connection on the
Islatrol® SP-6TVN and connect the other end to the original connec-
tion on the home entertainment equipment. If you have a second video device to protect, perform the same steps using the second
coaxial cable that came with your Islatrol
Step 3: Connecting your Telephone Electronics to the Islatrol® SP-6TVN/SP-6TN
Disconnect the end of your telephone line where it comes out of the wall. Connect it to one of the “OUT” telephone port connec­tions, (see diagram) on the Islatrol® SP-6TVN/SP-6TN. (Note: Do not use the data port for telephone line suppression). Connect one end of the telephone line patch cord that came with the Islatrol® SP­6TVN/SP-6TN to the “IN” line connection on the Islatrol® SP­6TVN/SP-6TN. Connect the other end to the original wall outlet.
Step 4: Connecting Network Electronics to
the Islatrol® SP-6TVN/SP-6TN
Disconnect the end of your network line from your computer or
router. Plug the end of the line to the Islatrol® SP-6TVN/SP-6TN
network connector ports marked “IN”. Connect one end of the
network line patch cord that came with the Islatrol® SP-6TVN/SP-
6TN to the “OUT” connection on the Islatrol® SP-6TVN. Connect the
other end to your computer or router.
The Islatrol® SP-6TVN/SP-6TN must be properly
®
SP-
®
SP-6TVN/SP-6TN receptacles on each side to provide
®
SP-6TVN.
Why the Islatrol® SP-6TVN/SP-6TN Industrial Strength Surge Suppressor with
Active Tra cking® Filter
technology is
Simply the Best
power protection for your home and office equipment…
Special Circuitry: The Islatrol® SP-6TVN/SP-6TN multi-stage suppressor contains specia­lized circuitry to eliminate damage from surges. Part of the circuitry is an internal fuse that will open in the rare event the Islatrol® SP-6TVN/SP-6TN is overloaded or exposed to a high-energy surge beyond its capacity.
Indication: Although there is an indicator on the Islatrol® SP-6TVN/SP-6TN to show if the suppressor is functioning, often suppressors are hidden behind furniture and other ob­jects that prevent you from seeing the indicator.
The Islatrol® SP-6TVN/SP-6TN has a second method to inform you if the suppression fails. The internal fuse will open and you will lose power to your electronics. In the rare event this occurs, please contact the office where you purchased your Islatrol® SP-6TVN/SP­6TN regarding any warranty repair/return instructions.
Load size: You may plug up to a 15 amp device into the SP-6TVN/SP-6TN without over­loading it.
Video: The Islatrol® SP-6TVN/SP-6TN video protection consists of two modules—either is suitable for satellite dish protection, cable TV, cable modems, and any other video de­vice.
Telephone: The Islatrol® SP-6TVN/SP-6TN telephone protection is designed for any tele­phone application such as modems, fax machines, pay-per-view, DSL and other phone use.
Warranty
The Islatrol® SP-6TVN/SP-6TN comes with a standard manufacturer’s limited warranty on defects in materials and workmanship. The warranty provides repair or replacement ap­pliance coverage up to a limit. Contact the office where you purchased your Islatrol® SP­6TVN/SP-6TN for more information and warranty details.
Troubleshooting
If, in Step 1 and 2 on the previous page, the Islatrol® SP-6TVN/SP-6TN indicator did not illuminate:
1. Try plugging it into a different wall receptacle. If the light illuminates, then the Isla-
®
trol
SP-6TVN/SP-6TN is operating properly and your first wall receptacle needs re-
pair. Please contact an electrician to repair your receptacle.
2. If the Islatrol a. Your building wiring may not contain a ground conductor. In this case, the indicator
b. The Islatrol
On a very rare occasion, your protected electronic appliance may not have power. This is an indication that the Islatrol fuse is damaged. In this case, please contact your supplier for any warranty repair/return in­structions.
Nominal Operating Voltage 120V Connection Type RJ11 Maximum Operating Voltage 130V Peak Surge Current 2kA
Mode of Protection L-N, L-G, N-G
Video Protection
Modes of Protection L-G Modes of Protection L-G
®
SP-6TVN/SP-6TN does not illuminate in a different receptacle:
light will not illuminate but you will still have power out of the Islatrol
®
SP-6TVN/SP-6TN may have been damaged, please contact your
supplier for any warranty return/repair instructions.
®
SP-6TVN/SP-6TN has been overloaded and the internal
Network Protection
®
SP-6TVN.
Loading...