Quick Start Guide
00825-0100-4211, Rev BA
December 2020
Rosemount™ Wireless Permasense
ET210 Corrosion Transmitter
Quick Start Guide December 2020
NOTICE
This guide provides basic guidelines for the installation of the Rosemount Wireless Permasense ET210
Corrosion Transmitter. It does not provide instructions for configuration, diagnostics, maintenance,
service, troubleshooting or intrinsically safe (I.S.) installations. Refer to the Rosemount Wireless
Permasense ET210 Corrosion Transmitter Reference Manual for more instruction. The manual and this
guide are also available electronically on Emerson.com\Rosemount.
Shipping considerations
Each device contains two “D” size primary lithium-thionyl chloride battery cells. Primary lithium
batteries are regulated in transportation by the U.S. Department of Transportation, and are also
covered by IATA (International Air Transport Association), ICAO (International Civil Aviation
Organization), and ARD (European Ground Transportation of Dangerous Goods). It is the responsibility
of the shipper to ensure compliance with these or any other local requirements. Consult current
regulations and requirements before shipping.
WARNING
Explosion hazard
Explosions could result in death or serious injury.
Installation of this transmitter in an explosive environment must be in accordance with the appropriate
local, national, and international standards, codes, and practices. Review the approvals section of this
manual for any restrictions associated with a safe installation.
Before connecting a CC21 in an explosive atmosphere, make sure the instruments in the segment are
installed in accordance with intrinsically safe or non-incendive field wiring practices.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
conditions:
This device may not cause harmful interference.
This device must accept any interference received, including interference that may cause undesired
operation.
This device must be installed to ensure a minimum antenna separation distance of 8-in. (20 cm) from
all persons.
Electrostatic hazard
The power module may be replaced in a hazardous area. The power module has surface resistivity
greater than one gigaohm and must be properly installed on the wireless device. Care must be taken
during transportation to and from the point of installation to prevent a potential electrostatic charging
hazard.
Polymer enclosure has surface resistivity greater than one gigaohm.
Care must be taken during transportation to and from the point of installation to prevent a potential
electrostatic charging hazard.
2 Emerson.com/Rosemount
December 2020 Quick Start Guide
WARNING
Physical access
Unauthorized personnel may potentially cause significant damage to and/or misconfiguration of end
users’ equipment. This could be intentional or unintentional and needs to be protected against.
Physical security is an important part of any security program and fundamental to protecting your
system. Restrict physical access by unauthorized personnel to protect end users’ assets. This is true for
all systems used within the facility.
Contents
Overview......................................................................................................................................5
Wireless considerations................................................................................................................7
Field communicator connections................................................................................................. 8
Physical installation...................................................................................................................... 9
Commissioning device............................................................................................................... 12
Product certifications................................................................................................................. 15
Quick Start Guide 3
Quick Start Guide December 2020
4 Emerson.com/Rosemount
December 2020 Quick Start Guide
1 Overview
Figure 1-1: Rosemount Wireless Permasense ET210 Corrosion
Transmitter
A. Antenna
B. Power module
C. Head
D. Lanyard hole
E. Strap slot
F. Foot
G. Cap
H. Shoe
Quick Start Guide 5
Quick Start Guide December 2020
1.1 Required equipment - IK220
1.2 Required tooling
Tooling is supplied in the Permasense IK220 Installation Kit:
• Hex key, 2.5 mm, for power module retaining bolts
• Strap tightening tool - HCL SM-FT-2000
1.3 What's in the box
• Rosemount Wireless Permasense ET210 transmitter, complete with
protective cap
• Lanyard kit, 316 stainless steel lanyard 6.5 ft. (2 m) in length, gripple No.
2, release key
• Silicone rubber shoe
• Strap kit, comprising polymer strap and buckle
• Rosemount Permasense BP20E power module
• M3 x 16 mm stainless steel retaining bolts, two per sensor
6 Emerson.com/Rosemount
December 2020 Quick Start Guide
2 Wireless considerations
Power up sequence
The Emerson Wireless Gateway should be installed and functioning properly
before any wireless devices are powered. Commission the Rosemount
Wireless Permasense ET210 and install the BP20E power module to power
the device only (following instructions below) after the gateway has been
installed and functioning. This results in a simpler and faster network
installation. Enabling active advertising on the Gateway ensures new devices
are able to join the network faster. For more information see the Emerson
Wireless 1420 Gateway Reference Manual .
Antenna position
The antenna is internal to the Rosemount Wireless Permasense ET210
transmitter. The antenna should also be approximately 3 ft. (1 m) from any
large structure, building, or conductive surface to allow for clear
communication to other devices.
Quick Start Guide 7
Quick Start Guide December 2020
3 Field communicator connections
The CC21 commissioning cable is connected and removed from the
transmitter in the same way as the Rosemount BP20E power module. The
USB connector is plugged in to the tablet PC as shown in Figure 3-1.
Figure 3-1: IK220 Commissioning Kit
A. Tablet PC
B. CC21
C. USB cable plugged into USB port
D. Rosemount Wireless Permasense WT210/ET210 sensor
8 Emerson.com/Rosemount