Emerson ES-805 Series, ES-905 Series, ES-805-SO, ES-805-PSO, ES-905-SO Instruction Manual

...
Instruction Manual D104466X012
ES-805 and ES-905 Series
April 2019
ES-805 and ES-905 Series Vent Valves
Table of Contents
Introduction ............................................................................1
Specifications ........................................................................2
Principle of Operation ............................................................2
Model Identification................................................................2
Installation .............................................................................2
Maintenance ..........................................................................5
V-ring Replacement ...............................................................6
Retrofit ES-805 and ES-905 Series Pallet Assembly ............6
Parts Ordering .......................................................................6
Parts List................................................................................7
Figure 1. Typical ES-805 Series In-Line Vent Valve
WARNING
!
Failure to follow these instructions or to properly install and maintain this equipment
chemical contamination causing property damage and personal injury or death.
Enardo™ vent valves must be installed, operated and maintained in accordance with federal, state and local codes, rules and regulations and Emerson Process Management Regulator Technologies Tulsa, LLC instructions.
Failure to correct trouble could result in a
hazardous condition. Call a qualied service
person to service the unit. Installation, operation and maintenance procedures
performed by unqualied person may result
in improper adjustment and unsafe operation. Either condition may result in equipment
damage or personal injury. Only a qualied
person shall install or service the vent valves.
Introduction
Scope of the Manual
This Instruction Manual provides instructions for installation, maintenance and parts ordering guide for the ES-805 and ES-905 Series vent valves.
Figure 2. Typical ES-905 Series End-of-Line Vent Valve
WARNING
!
The ES-805 and ES-905 Series vent valves is not necessarily grounded when installed on
berglass reinforced plastic tanks unless the base is electrically bonded to the tank.
To avoid personal injury or property damage resulting from the effects of a static electricity discharge from hatch components in a hazardous atmosphere or where the process
uid is combustible, electrically bond the base to the tank with grounding strap.
North America Only
ES-805 and ES-905 Series
Specications
The Specications section on this page provides specications for the ES-805 and ES-905 Series vent valves. Specications
such as model number, connection size, date of manufacture, valve type, seal materials and pressure/vacuum settings are stamped on the nameplate attached to the vent valve. Weights are keyed to the pallet stem. Every weight is stamped with the setting (oz.), the valve size and the part number.
Available Construction
See Figure 3
Available Sizes
2 through 4 in. / 50 through 100 mm
Set Pressure/Vacuum
See Table 1
Construction Materials
See Table 2
1. The pressure limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.
(1)
ES 8 25 PSO
Series
8 = 805 9 = 905
Figure 3. Model Number Identification
Size
25 = 2 in. 35 = 3 in. 45 = 4 in.
Product Description
ES-805 and ES-905 Series vent valves represent the latest development in high-performance, tight-sealing tank venting products and complement Enardo™’s industry-leading ES-665 Series thief hatch product line. With a leakage rate of no more than 0.1 SCFH at 90% of set point, the ES-805 and ES-905 Series offers unparalleled vent valve performance.
Model ES-805-SO - is an In-line vent valve. It is installed directly into the vent line exhaust. The Model ES-805-SO has both pressure and vacuum relief capability.
Model ES-805-PSO - is a pressure only vent valve designed to relieve pressure only through the vent line. It is designed the same as the Model ES-805-SO pressure/vacuum except they omit the vacuum side of the valve that eliminates the
possibility of two way ow.
Model ES-905-SO - is an end-of-line vent valve. The end-of-line vent valve is installed directly on the end of the vent line exhaust. The Model ES-905-SO has both pressure and vacuum relief capability.
Model ES-905-PSO - is an end-of-line vent valve. The end-of-line vent valve is installed directly on the end of the vent line exhaust. The Model ES-905-PSO only has pressure relief capability.
Principle of Operation
ES-805 and ES-905 Series vent valves are designed to prevent the escape of light ends of crude by maintaining pressure in the storage tank.
Approximate Weight
ES-805 Series Vent Valve
2 In. / 50 mm body: 12 lbs. / 5 kg 3 In. / 80 mm body: 17 lbs. / 8 kg 4 In. / 100 mm body: 23 lbs. / 10 kg
ES-905 Series Vent Valve
2 In. / 50 mm body: 11 lbs. / 5 kg 3 In. / 80 mm body: 15 lbs. / 7 kg 4 In. / 100 mm body: 19 lbs. / 9 kg
The vent valve opens when the system pressure or vacuum exceeds the set pressure of the valve. When over pressure occurs, the pallet lifts, breaking the seal between the seat
and pallet, allowing vapors to pass through the valve orice
and relieving the pressure or vacuum buildup. The valve closes once the tank pressure goes below the set pressure.
Model Identication
Tagging Information
For ES-805 Series, the nameplate is located on the unit’s lid and for ES-905 Series, the nameplate is located on the unit’s hood. Actual layout of nameplate may vary.
Installation
The valve and its pallet assembly are shipped separately. The pallet assembly may be heavy and can cause personal injury or damage to the unit if not handled with care.
All wing-nuts shall be hand tightened only. Tools are not to be used.
Prior to installation, remove the unit from its packaging and discard any protective coverings. Below is a list of instructions that are recommended for the installation of an Enardo vent valve.
Pressure Type
SO = Pressure and Vacuum PSO = Pressure Only
WARNING
!
North America Only
2
ES-805 and ES-905 Series
ES-905 SERIES NAMEPLATE LOCATION ES-805 SERIES NAMEPLATE LOCATION
Figure 4. Nameplate Location
Figure 6. Nameplate ExampleFigure 5. ES-805 and ES-905 Series Weights
Table 1. Vent Setting Range
MODEL SIZE PRESSURE VACUUM
ES-805-SO
ES-805-PSO N/A
ES-905-SO 0.4 oz./sq.in. / 1.7 mbar
ES-905-PSO N/A
2 through 4 in. / 50 through 100 mm
1.0 to 16.0 oz./sq.in. / 4.3 to 6.90 mbar (0.5 oz./sq.in. / 2 mbar increments)
0.4 oz./sq.in. / 1.7 mbar
Table 2. Construction Materials
MODEL HOUSING PALLET V-RING SEAL HARDWARE WEIGHTS GASKETS
ES-805-SO
ES-805-PSO
ES-905-SO
ES-905-PSO
Cast Aluminum Aluminum
Nitrile (NBR) or
Fluorocarbon (FKM)
Zinc-plated carbon steel
Zinc-plated carbon steel
(to 12 oz./sq.in.)
or Lead
Nitrile (NBR) or
Fluorocarbon (FKM)
North America Only
3