Features
Primary and secondary protection
UL 497 and UL 497A Listed*
Patent pending UHS technology
Silicon foldback technology
Auto reset fusing (PTCs)
Surge and sneak current protection
Edco™H Series
Telecom/Punch Block Primary/Secondary Protection
Power Switching & Controls For Business-Critical Continuity
TM
The Edco H Series modules are ultra high speed fused solid state dual listed Primary (UL 497) and Secondary (UL 497A) protectors for KEY/PABX systems. The units are available in two different clamping voltages. The Edco H Series is constructed with solid state silicon foldback technology, polyswitch resettable fuses — PTCs — and failure fuses. The protective elements switch from the normal high-impedance state to a low-impedance state upon a detection of a surge, then switch back to high impedance after the surge has passed. The Edco H Series single pair modules fit onto a standard Edco MI-50 split block and replace bridging clips. In addition, these modules require the Edco MGB Ground Rail for each Edco MI-50 block used.
Operating Voltage 48, 200 VDC
Clamping Voltage (HDE) 65
Primary Breakdown Range (HCO) 202 -625 VDC
Operating Current 0.15A
Peak Surge Current 160A (10 x 1000 T & R to Gnd)
Frequency Range 0 to 20MHz
Insertion Loss < 0.1 dB at 20MHz
SPD Technology Silicon Breakover Device w/Series PTC
Connection Type Clip
Operating Temperature -40°C to +85°C
Dimensions (Inches) 1.25H x 0.4W x 2.8L
Weight 1 oz
Warranty 5 years
Digital Extensions HDE
Central Office/Trunks HCO
General Technical Specifications
Ordering Information
DO NOT daisy chain grounds. NOT intended for shield termination. Install ground in accordance with all applicable codes.
* The protector is to be used in a Listed enclosure
when used as a Primary protector and may or may not be used in a Listed enclosure when used as a Secondary protector.
**#6 AWG wire to building approved ground -
keep short. See UL 497, paragraph 7.2.2 for more information
Installation
IO-50134 9/13 Rev. 2 Printed in USA
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2013 Emerson Electric Co.
www.emersonnetworkpower.com/surge
Emerson Network Power Contact information
Headquarters
Surge Protection 100 Emerson Parkway Binghamton, New York 13905 T: (607) 721-8840 T: (800) 288-6169 F: (607) 722-8713 E: surgetech@emerson.com
AC Power
Connectivity
DC Power
Embedded Computing
Embedded Power
Industrial Power
Infrastructure Management & Monitoring
Outside Plant
Thermal Management
Racks & Integrated Cabinets
Power Switching & Controls
Services
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity
TM
.
Installation should be performed by qualified personnel ONLY and in compliance with NEC Article 800.30 for primiary protection and NEC article 800.32 for secondary protecton.
**
Loading...