Emerson CROFTON CF790BS00, CROFTON CF790VNB00, CROFTON CF790SW00, CROFTON CF790VS00 Owner's Manual

READ AND SAVE THESE INSTRUCTIONS
58” Ceiling Fan Owner's Manual
Model Numbers
CF790BS00
Brushed Steel with
Walnut/Dark Mahogany Blades
CF790SW00
Satin White with
Satin White/Maple Blades
Net Weight: 25.5 Lbs.
Questions, problems, missing parts: Before returning to the store call
Emerson Electric Customer Service 8 a.m. - 6 p.m., Eastern, Monday-Friday
1-800-654-3545
Part No. F40BP74940000 Form No. BP7494 Revision: 150610 ETL Model No.: CF790
www.emersonfans.com
CF790VNB00
Venetian Bronze with
Walnut/Dark Mahogany Blades
CF790VS00
Vintage Steel with
Walnut/Riverwash Blades
• Español - página 29
• Français - page 57
Table of Contents
Section Page
Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1. Unpacking Instructions . . . . . . . . . . . . . . . . . . . . .3-4
2. Electrical Requirements . . . . . . . . . . . . . . . . . . . . .4
3. Ceiling Fan Assembly . . . . . . . . . . . . . . . . . . . .5-10
. How to Hang Your Ceiling Fan . . . . . . . . . . . .11-12
4
5. How to Wire Your Ceiling Fan . . . . . . . . . . . . .13-15
6. Wall Control Procedures . . . . . . . . . . . . . . . . . . . .16
7. Wall Control Installation . . . . . . . . . . . . . . . . . .17-20
8. Programming the Receiver Operating
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . .21
READ AND SAVE THESE INSTRUCTIONS
Safety Instructions
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR I N J U R Y TO P E R S O N S , OBSERVE T H E FOLLOWING:
a. Use this unit only in a manner intended by the
manufacturer. If you have questions, contact the manufacturer.
b. Before servicing or cleaning unit, switch power off
at service panel and lock serv i c e p a n e l disconnecting means to prevent power from being switched on a c c i d e n t a l l y . W h e n t h e service disconnecting means cannot be locked, securely fa sten a warnin g devic e, s uch as a tag, to the service panel.
1. Read your owner’s manual carefully and keep it for future reference.
2. Be careful with the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
3. Do not put anything into the fan blades while they are turning.
4. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for
Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National El ectri cal C ode “AN S I/NF P A 70 -2014 ” an d Lo c al Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical sh ock. Ele ctric al insta llat ion sho uld be made or approved by a licensed electrician.
!
Section Page
9. Using Your Ceiling Fan . . . . . . . . . . . . . . . . . . . .22
10. Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
11. Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
12. Instruction to the User . . . . . . . . . . . . . . . . . . . . .23
3. Repair Parts . . . . . . . . . . . . . . . . . . . . . . . . . .24-25
1
14. Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . .26
Ceiling Fan Limited Warranty . . . . . . . . . . . . . . . . . .27
Spanish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
French . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use the mounting s c r e w s provided w i t h the outlet b o x . Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished wit h the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolat ing w all control/ switch.
NOTE: This fan is suitable for use with solid-state speed controls.
WARNING: To reduce the risk of fire or electrical shock, this fan should only be used with fan speed control, Model No. UC7067RA, manufactured by Rhine Electric Co., Ltd.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
NOTE: All setscrews must be checked and re-tightened where necessary before installation.
DATE CODE:
The date code of this fan may be found on the box, stamped in ink on a white label. You should
record this data above and keep it in a safe place for future use.
ETL Model No.: CF790
2
B
A
C
H
I
F
G
OFF ON
....
OFF ON
....
OFF ON
....
OFF ON
....
J
K
D
E
1. Unpacking Instructions
5
10
7
9
8
11
4
1
2 3
6
WARNING
Do not install or use fan if any part is damaged or missing. Call Toll-Free for replacement parts:
!
1-800-654-3545
WARNING
This pr oduct is de signed to use only those pa rts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
!
1.1
Check to see that you have received the following parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration below.
HARDWARE BAG CONTENTS
Part Description Quantity
1 Threaded Studs, #8-32 x 1-1/4” 2
2 Knurled Knobs, #8-32 2 3 Lockwashers, External Tooth #8 2 4 Wire Connectors 3 5 Clevis Pin 1 6 Hairpin Clip 1 7 #8-32 x 5/16” Round Head Screw (spare) 1 8 #8-32 x 5/16” Flat Head Screw (spare) 1 9 #10-32 x 1/4” Washer Head Screws 16 10 1/4-20 x 1/2” Round Head Screws
with Lockwashers 11 11 Blade Balance Kit 1
PACKAGE CONTENTS
Part Description Quantity
A Fan Motor Assembly 1
B Ceiling Canopy 1
C Motor Coupler Cover 1 D Switch Housing Adapter 1 E Switch Housing Assembly 1
F Fan Blade Flanges 5 G Ceiling Fan Reversible Blades 5 H Hanger Bracket 1
I Hanger Ball/4.5” Downrod Assembly 1
J Wall Control w/Hardware 1 K Receiver 1
NOTE: Place the parts from the loose parts bags in
a small container to keep them from being lost.
If any parts are missi n g , c a l l 1 - 800-654-35 4 5
for replacement parts before proceeding.
1.2
Remove th e f a n a s s embly from th e p r o t ective
plastic bag. Place the fan assembly into the upper
styrofoam with the top of the motor facing up.
The upper styrofoam serves as a holder for the fan
during the first stages of assembly.
emersonfans.com
Please contact 1-800-654-3545 for further assistance
3
ETL Model No.: CF790
1. Unpacking Instructions (Continued)
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver One stepladder One 1/4” blade screwdriver One wire stripper
Materials
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of following size:
Installed Wire Length Wire Size A.W.G. Up to 50 ft. 14
50-100 ft. 12
2. Electrical Requirements
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
WARNING
To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or less”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptabl e for f a n support and may n e e d to be replaced. Consult a qualified electrician if in doubt.
WARNING
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceilin g fan m u s t be p r o p e rly gr o u n d e d as a precaution against possible electrical shock.
!
!
WARNING
efore assembling your ceiling fan, refer to section on
B proper method of wiring your fan (page 13). If you feel you do no t h a v e e n o u g h w i r i n g k n o w l e d g e or expe rience, have your fan instal led by a licensed electrician.
!
Controls Sold Separately
SR400 Remote Control (sold separately) may be used with this Crofton Ceili n g Fa n . Co n t r ols ar e recommended for indoor use only.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
WARNING
To avoid fire or shock, follow all wiring instructions carefully.
Any e l e c t r i c a l wo r k no t de s c r i b e d in th e s e instructions should be done or approved by a licensed electrician.
Please c a l l Emerson te c h n ical supp o r t at 1- 800-654-354 5 if you ha ve any ques tions about installation and operation of this ceiling fan.
!
ETL Model No.: CF790
4
3. Ceiling Fan Assembly
SETSCREW (LOOSENED)
HANGER BALL
4.5" DOWNROD
PIN
4.5" DOWNROD
THREE 80" MOTOR
LEADS (UNTWISTED)
3.1
Disconnect electrical power to the branch circuit at the circuit breaker or fuse box before attempting to install
he ceiling fan mounting plate on the outlet box.
t
3.2
Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1).
Remove the pin from the downrod, then remove the hanger ball.
Retain the pin and hanger ball for reinstallation in Step 3.8.
NOTE: Do not loosen the screw holding the green ground wire.
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceilin g fan m u s t be p r o p e rly gr o u n d e d as a
recaution against possible electrical shock.
p
!
WARNING
Figure 1
3.3
Separate, untwist and unkink the three 80” motor leads.
Ro ute th e 80” black, blue a nd whi te mot or leads through the downrod (Figure 2).
5
Figure 2
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF790
3. Ceiling Fan Assembly (Continued)
MOTOR COUPLING
4.5" DOWNROD
CLEVIS PIN
HAIRPIN CLIP
HAIRPIN CLIP
CLEVIS PIN
LOOSEN SETSCREWS (2)
RETIGHTEN SETSCREW
4.5" DOWNROD
COUPLING COVER
GROMMET
3.4
Loosen the two setscrews in the motor coupling.
Place the 4.5” downrod into the motor coupling, aligning the clevis pin holes in the downrod with the holes in the
otor coupling (Figure 3).
m
he clevis pin must go through the holes in the motor
T coupling and the holes in the downrod.
Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin.
The hairpin clip must be properly installed to prevent the clevis pin from working loose.
Pull on the downrod to make sure the clevis pin is properly installed.
WARNING
It is critical that the clevis pin in the motor coupling is properly installed. Failure to verify that the pin is properly installed could result in the fan falling.
!
3.5
While pulling up on the 4.5” downrod, retighten the two setscrews (previously loosened) in the motor coupling to secure the downrod into place (Figure 4).
NOTE: The setscrews must be properly installed as described above, or fan wobble could result.
WARNING
It is critical that the setscrews are securely tightened. Fa ilure to verif y th a t th e se tscre w s ar e pr operl y installed could result in the fan falling.
!
3.6
Make sure the grommet is properly installed in the coupling cover then slide the coupling cover on the downrod until it rests on the motor housing (Figure 5).
Figure 3
Figure 4
ETL Model No.: CF790
Figure 5
6
3. Ceiling Fan Assembly (Continued)
4.5" DOWNROD
CEILING COVER
4.5" DOWNROD
HANGER BALL
PIN
SETSCREW
HANGER BALL/ DOWNROD ASSEMBLY
6 to 9
INCHES
3.7
Place the ceiling cover over the downrod. Be sure both the ceiling cover and the coupling cover are oriented correctly (Figure 6).
3.8
NOTE: Only use the hanger ball supplied with this ceiling fan.
Figure 6
Route the three 80” motor leads through the hanger ball.
Reinstall the hanger ball (Figure 7) on the downrod as follows:
Position the hanger ball pin through the two holes in the downrod and align the ball so the pin is captured in the groove in the top of the hanger ball.
Pul l the h a nger ba l l up ti g ht agai n st the pin and securely tighten the setscrew in the hanger ball.
NOTE: A loose setscrew could create fan wobble.
3.9
The fan comes with black, blue and white leads that are 80-inches long.
Before installing the fan, measure up approximately 6 t o 9 - i n c h e s above top of hanger ball/downrod assembly (Figure 8).
Cut off excess leads and strip back insulation 1/2-inch from end of leads.
Figure 7
7
Figure 8
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF790
3. Ceiling Fan Assembly (Continued)
STYROFOAM
PARTIALLY ASSEMBLED CEILING FAN
SHIPPING SPACER
SHIPPING SPACER SCREW
FAN ASSEMBLY
BLADE FLANGES (5)
#10-32 x 1/4" WASHER HEAD SCREWS (3)
REVERSIBLE FAN BLADES (5)
3.10
Carefully turn the partially assembled ceiling fan over and place it on the styrofoam for final preparation
Figure 9).
(
3.11
Remove t h e shipp i n g spacer s a nd the s p acer attachment screws from the motor before installation of blade assemblies (Figure 10).
Discard the spacers and spacer screws.
Figure 9
3.12
Your ceiling fan is supplied with one set of 5 reversible fan blades. Choose the finish to compliment your decor and mount the blades to the blade flanges as follows:
Mount blade flanges to ceiling fan blades using three #10-32 x 1/4” wa s h e r head s crews ( s u p plied) (Figure 11).
Repeat this procedure for the other four fan blades and blade flanges.
Figure 10
Figure 11
ETL Model No.: CF790
8
3. Ceiling Fan Assembly (Continued)
1/4-20 x 1/2" ROUND HEAD SCREWS WITH LOCKWASHERS (2 per blade/flange assembly)
BLADE/FLANGE ASSEMBLIES (5)
MOTOR HUB
INTERLOCKING FLANGE AREA
SWITCH HOUSING ADAPTER
REMOVE ONE #8-32 x 5/16" ROUND HEAD SCREW
LOOSEN TWO #8-32 x 5/16" ROUND HEAD SCREWS
3.13
Loosely attach one blade/flange assembly to the motor hub by securing the two 1/4-20 x 1/2” round head
crews with lockwashers (Figure 12).
s
Make sure the screws are NOT procedure for other four blade/flange assemblies.
NOTE: The blad e flanges have an int erlocking featur e t hat mus t b e fully e n g aged be f o r e tightening the screws. Make sure all the flanges are pr o perly e ngaged and the n tight en the flange screws. If one of the flanges does not seat properly on the mot or hub, loosen t he adja cent fla nge screws, re-engage and reseat the flanges, then tighten the screws again.
tightened. Repeat this
3.14
Once all five blade/flange assemblies are secured to the motor hub, proceed to tightening all 1/4-20 x 1/2” round head screws with lockwashers at this time.
WARNING
To reduce the risk of personal injury, do not bend the blade f l a n g e when installing t h e blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
!
Figure 12
3.15
Remove one #8-32 x 5/16” round head screw from the motor housing (reserve for later use).
Loosen the other two screws to assemble the switch housing adapter to the motor housing (Figure 13).
3.16
Rotate the switch housing adapter to engage the two loosened screws in the two key hole slots.
Replace the #8-32 x 5/16” round head screw (removed previously) and tighten all three screws to secure the switch housing adapter to the motor housing.
NOTE: Make sure wires are not pinched between the switch housing adapter and the motor housing.
Spare #8-32 x 5/16” round head screw is provided in parts bag if needed.
9
Figure 13
emersonfans.com
Please contact 1-800-654-3545 for further assistance
ETL Model No.: CF790