Emerson CP-70R Brochures and Data Sheets

Chloride CP-70R 10 Rectier-Charger
25 to 250A - 1ph input
Industrial Power for
Business-Critical Continuity™
The Chloride CP-70R industrial rectier­battery charger is the agship rectier of Chloride Industrial Power. It combines conservative design topology with proven digital control technology to offer the best performances in any electrical and environmental condition.
The Chloride CP range is designed to meet the stringent electrical and mechanical requi­rements in industrial environments. Each Chloride CP product is based on interchangeable sub-assemblies to allow full customization, in compliance with client’s technical specication and with project docu­mentation requirements.
Benets
n Made to order DC back-up power solutions
to exactly t the industrial application
requirements
n Complete power protection solution,
including switchgear, DC distribution, monitoring suite
n Ruggedized solutions for demanding
environments: extended temperatures, vibrations, dust, elevation, dripping water and moisture.
Key Features
n Reliability - Unique design which allows the
rectier to continuously operate at full load at
a permanent 40°C ambient temperature.
n High MTBF - Natural cooling available on
most of the range.
n Reduced MTTR - Direct access to
components from the front of the equipment.
n Robustness - Mechanical design to withstand
vertical and horizontal acceleration stress up to 0.5g as standard.
n 20 years + life span - system design to meet
industrial requirements, with appropriate maintenance.
n Isolation transformer n Multilingual digital graphic display with
embedded event log
n Remote monitoring capabilities: Modbus,
Probus, DF1, Ethernet, volt-free contacts,
monitoring software
n Full compatibility with lead-acid and nickel-
cadmium batteries, sealed or vented
Applications
The Chloride CP-70R Rectier-Charger range suits
all DC applications requiring a large battery back­up:
n Power Transmission and Distribution n Continuous process industries n Oil and Gas and Petrochemical industries n Transportation (rail, metro, tramway)
The Chloride CP range is designed to meet the harshest electrical and mechani­cal requirements in industrial environments. Each Chloride CP product is based on interchangeable sub-assemblies to allow
full customization, in compliance with client’s technical specication and with project documentation requirements.
Associated with an industrial stand-by battery, the Chloride CP-70R range pro­tects DC critical industrial equipments and processes from the damaging effects of power interruptions and losses.
Chloride CP-70R 10 Rectier-Charger
25 to 250A - 1ph input
Industrial Power for
Business-Critical Continuity™
Ratings - Output current (A) vs voltage (VDC)
24 Vdc 48Vdc 110-120Vdc
25 25 25
60 60 60
100 100 100
160 160 160
250 250 250
Options
Rectier Ripple lters
Blocking diode
Dropping diodes
Other input voltage
Surge and Lightning protections
Battery Battery circuit protection box
Battery cabinet
Low-voltage disconnect contactor
Battery middle-point measure
Battery Management System
Battery room temperature sensor
System Dual or trial congurations
Hot stand-by conguration
DC/DC serial regulator
Isolated DC/DC converter
DC distribution
Earth fault monitoring
Internal lighting
Anti-condensation heater
Temperature monitor
Special cabinet identication
Mechanical Up to IP65 external
Top cable entry
Other frame colour
Anti-seismic design
Communication Front-panel analog meters (72x72 class 1.5)
Transducers
Volt-free contacts
Remote monitoring via Modbus
Remote monitoring via other bus
PPVis monitoring software
Non-exhaustive list of options. Consult us for any other requirements.
Passive or active mimic panel
Technical Data
Input
Nominal AC voltage 1 x 230 V (220, 240)*
Input voltage tolerance +/- 10%
Input frequency 50Hz (60Hz)
Input frequency tolerance +/- 5%
Intermediate DC Circuit
Nominal DC voltage 24 / 48 / 110 / 120
Available ratings see table above
Voltage stability +/- 1% in oat mode, input within tolerance
Voltage ripple 1% RMS, in oat, battery connected
Current limitation I nominal
Characteristic UI according to DIN 41773
Battery
Typ e Lead Acid or Nickel Cadmium vented or
Autonomy From few minutes to several hours, as per
Battery current limitation
(typical, oat & charge modes)
Battery current limitation (typical, boost mode)
General Data
Operating temperature 0 to 40°C*
Storage temperature (°C) -20 to +70°C
Relative humidity (%) <90% non condensing
Operating altitude (m) 1000 m max without derating
Cooling Natural convection
Efciency Up to 89% according to rating
External protection IP 20* according to IEC 60529
Noise (dB) 55 – 65 dB according to rating
Frame colour Grey RAL 7032
Dimensions Varying according to ratings & options
* other available on request
Standards
Compliance IEC 60146 – IEC 60439 - IEC 60726 –IEC 61000-6-2
IEC 61000-6-4 – IEC 62040 (-1, -2, -3)
Conformity Low voltage directive: 2006/95/EC
EMC directive: 2004/108/EC
CE Mark
+/-1.5% for parallel rectiers
recombination
customer’s requirement
0.1C (Lead Acid battery)
0.2C (Nickel Cadmium battery)
0,05C (Lead acid battery)
0.1C (Nickel Cadmium battery)
While every precaution has been taken to ensure the accuracy and completeness of this literature, Emerson Network power assumes no responsability and disclaims all liability for damages resulting from use of this information or for any errors or
omissions.
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity™.
Emerson Network Power I S S.A.S
30 Avenue Montgol er - BP90 - 69684 Chassie u Cedex France T: +33 (0)4 78 40 13 56 F: +33 (0)4 78 90 58 90 Industrial.Sales.Chloride@Emerson.com
EmersonNetworkPower.com
n AC Power n Connectivity n DC Power n Embedded Computing
n Embedded Power
n Industrial Power
n Infrastructure Management & Monitoring n Outside Plant
Emers on Electric Co. or one of i ts afliate d companies.
CP70R 10 Rectier-Charger-DSUK-Re v2-02/2013
n Power Switching & Controls n Precision Cooling n Racks & Integrated Cabinets n Services
Emerson, Business-Critical Continuit y and
Emers on Network Po wer are trademarks of
©2013 Emerson Elec tric Co.
Loading...