Chloride CP-70i 01 - DC/AC inverter
2.5 to 250kVA - 1ph output
Industrial Power for
Business-Critical Continuity™
The Chloride CP-70i industrial
inverter is the agship inverter of
Chloride Industrial Power. It combines
conservative design topology with
proven digital control technology
to offer the best performances in
any electrical and environmental
condition.
The Chloride CP range is designed to meet
the stringent electrical and mechanical
requirements in industrial environments.
Each Chloride CP product is based on interchangeable sub-assemblies to allow full
customization, in compliance with client’s
technical specication and with project
documentation requirements.
Benets
n Made to order DC/AC inverter solutions
to exactly t the industrial application
requirements
n Ruggedized solutions for demanding
environments: high temperatures,
vibrations, dust, elevation, dripping water
and moisture
n Efcient maintenance thanks to easy
front-access to all vital modules of the
system
Custom-designed DC/AC inverters to supply critical industrial processes.
The Chloride CP-70i 01 converts a DC input voltage into a perfect sinusoidal singlephase output voltage to provide power to critical AC loads. It uses the patented digital
Vector Control technology which increases the performances of power components
and enables an active conditioning of the load. The result is improved reliability for the
process and enhanced safety for the personnel.
The CP-70i 01 range is available from 2.5kVA to 250kVA. It offers a wide choice of DC
input voltages (from 110Vdc to 240Vdc) and of output voltages.
The CP-70i 01 range is also available with 400Vdc input. This conguration can be
combined with a CP-70R 30 rectier-charger in order to design specic high ratings
double conversion AC UPS systems.
To further improve load availability and process reliability, the CP-70i 01 is able to
operate in dual parallel conguration, with centralized or distributed reserve line, and
can include an AC bus-tie.
Key Features
n Reliability - Unique design which allows
the inverter to continuously operate for at
least 20 years at full load at 40°C
n Robust mechanical design - The inverter
withstands vertical and horizontal
acceleration stress tests up to 0.5g as
standard
n Galvanic isolation - Output transformer is
included as standard
n Multilingual digital graphic display with
embedded event log
n Remote monitoring capabilities: Modbus,
Probus, DF1, ethernet, volt-free contacts,
monitoring software
n Fully customized electrical and mechanical
solutions – On demand design to comply
with every standard (e.g. UL, ANSI, NEMA,
IEC, CSA, ABS, DNV)
Applications
The Chloride CP-70i DC/AC inverter range suits
applications such as:
n Oil and Gas offshore and onshore
n Rening and petrochemical plants
n Conventional power generation plants
n Transmission and Distribution substations
n Transportation (rail, metro, tramway)
Chloride CP-70i 01 DC/AC inverter
2.5 to 250 kVA - 1ph output
Industrial Power for
Business-Critical Continuity™
Ratings - Output power (kVA) vs DC intermediate voltage (Vdc)
110–120Vdc 220-240Vdc
2.5
5
7.5
10 10
15 15
20 20
25 25
30 30
40 40
50 50
60 60
80 80
100 100
120 120
160
200
250
Options
Inverter Dual congurations
Input / output isolators
AC distribution
Earth fault monitoring
Internal lighting
Anti-condensation heater
Temperature monitor
Special cabinet identication
Reserve transformer
Reserve stabilizer
Mechanical Up to IP42 external
Top cable entry
Other frame colour
Anti-seismic design
Communication Front-panel analog meters (72x72 class 1.5)
Transducers
Additional Volt-free contacts
Remote monitoring via Modbus
Remote monitoring via other bus
PPVis monitoring software
Passive or active mimic panel
Non-exhaustive list of options. Consult us for any other requirements.
Technical Data
Input
DC voltage 110 / 120 / 220 / 240 (400V on request)
Voltage tolerance +18% /- 20%
Output
Available ratings see table (at PF 0.8 lagging)
AC Voltage 1 x 230V (220, 240) ; 1 x 110V (115, 120)*
Frequency 50Hz (60Hz)
Frequency stability
• with internal oscillator +/- 0.05%
• with reserve synchronism +/-4% (from 1.2 to 6% adjustable)
Frequency response <1Hz/s (0.1Hz/s for parallel systems)
Voltage stability (for 0-100% load variation)
• static +/-1% (+/-2% for parallel systems)
• dynamic VFI SS 111 - Complies with IEC/EN 62040-3,
Overload inverter
• 1 minute 150% of nominal power
• 10 minutes 125% of nominal power
Short circuit clearance
• 100 ms 250% of nominal current
• 5 s 175% of nominal current
Harmonic voltage distortion
• With 100% linear load < 3%
• With 100% non-linear load ≤ 5% (non linear load dened by IEC 62040)
Allowable power factor 0.5 lagging to 0.5 leading
Allowable crest factor 3/1
General Data
Operating temperature 0 to 40°C*
Storage temperature (°C) -20 to +70°C
Relative humidity (%) <90% non condensing
Operating altitude (m) 1000 m max without derating
Cooling Forced ventilation
Efciency Up to 91% according to rating
External protection IP 20* according to IEC 60529
Noise (dB) 60 – 75 dB according to rating
Frame colour Grey RAL 7032
Dimensions Varying according to ratings & options
* other available on request
Standards
Compliance IEC 62040 (-1, -2, -3) / 60146 (-1-1, -1-3, -2) / IEC 609650
Conformity Low voltage directive: 2006/95/EC
IEC 61000-6-2 - IEC 61000-6-4
IEC 60529 / IEC 60439 / IEC 60076
EMC directive: 2004/108/EC
CE Mark
class 1
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity™.
Emerson Network Power I S S.A.S
30 Avenue Montgol er - BP90 - 69684 Chassieu Cedex France
T: +33 (0)4 78 40 13 56 F: +33 (0)4 78 90 58 90
Industrial.Sales.Chloride@Emerson.com
EmersonNetworkPower.com
n AC Power
n Connectivity
n DC Power
n Embedded Computing
n Embedded Power
n Industrial Power
n Infrastructure Management & Monitoring
n Outside Plant
Emers on Electric Co. or one of i ts afliate d companies.
CP70i 01 DC/AC inverter- DSUK-Rev3-06/2013
While every precaution has been taken to ensure the accuracy and completeness of this literature, Emerson Network Power assumes no responsability and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
n Power Switching & Controls
n Precision Cooling
n Racks & Integrated Cabinets
n Services
Emerson, Business-Critical Continuit y and
Emers on Network Po wer are trademarks of
©2013 Emerson Elec tric Co.