Emerson CP400 Data Sheet

CP400 Series
Fisher® Commercial Service Reliability
CP400 Series
The Fisher® CP400 Series
The CP400 Series pressure loaded regulators have been
engineered to t a multitude of pressure-reducing applications including commercial and light industrial installations. This exibility is provided by the multiple body sizes, end connections, body materials, outlet pressure settings, and orice sizes. The CP400 Series provides accurate control for use in pressure-factor measurement (PFM) and Fixed Factor billing applications.
Overpressure protection is a strength of the CP400 Series due to multiple overpressure protection options that include Integral True-MonitorTM Protection and
Typical CP400 Internal View
Slam-shut Protection. Token Relief is also offered for relieving minor overpressure from nicks on the orice or from debris obstructing complete shutoff.
Product advantages:
• Wide variety of body sizes and end connections
• Fixed Factor / PFM Accuracy
• Multiple Overpressure Protection Options
• Integral Monitoring Regulator
• Integral Slam-shut
• Token Internal Relief
• Only standard tools required for pressure adjustment and orice removal
• Internal or external pressure registration
Overpressure Protection Options
INTEGRAL
MONITORING
REGULATOR
INTEGRAL
SLAM-SHUT
CP400 REGULATOR
Integral True-MonitorTM Protection
Combines the operation of a conventional two-regulator wide-open monitor set into one device without the need for a downstream control line.
CP400 REGULATOR
Slam-Shut
Shuts off gas service to the downstream system in the event of an overpressure or underpressure condition.
TOKEN RELIEF
Token Internal Relief (Located in the
Type 67CPR Pressure Loading Regulator)
Relieves minor overpressure caused by nicks on the orice/disk or debris obstructing complete shutoff and provides an indication via smell that an overpressure situation is occurring.
CP400 Series Features
Operation: Pressure Loaded Pressure Reducing Regulator Body Sizes and End Connections: 1-1/4, 1-1/2, and
2 NPT; Rp 1-1/4, 1-1/2, and 2; NPS 2, CL125 FF and CL150 FF Flanges; DN 50, PN 10/16 Flanges
Outlet Pressure Range: 1 to 20 psig (69 mbar to 1,4 bar) Maximum Outlet (Casing) Pressure: 25 psig (1,7 bar)
Natural Gas Technologies
Emerson Process Management Regulator Technologies, Inc.
North America McKinney, Texas 75069-1872 USA Tel: 1-800-558-5853 Outside U.S. 1-972-548-3574
Our Global Natural Gas Product Brands:
D351368X012 © 2009 Emerson Process Management Regulator Technologies, Inc. All rights reserved. Printed in the U.S.A. 11/09. Fisher, Francel, Tartarini, Emerson Process Management, and the Emerson Process Management design are marks of one of the Emerson Process Management group of companies. All other marks are the property of their respective owners.
Asia-Pacific Singapore, Singapore 128461 Tel: +65 6777 8211
For further information, visit www.emersonprocess.com/regulators
Temperature Capabilities: -20° to 150°F (-29° to 66°C) Pressure Registration: Internal or External Body Material: Gray Cast Iron, Ductile Cast Iron, and Steel Overpressure Protection:
• Integral Monitoring Regulator
• Integral Slam-shut
• Token Internal Relief
Europe
Bologna, Italy 40013 Tel: +39 051 4190611 Gallardon, France Tel: +33 (0) 2 37 33 47 00
The distinctive swirl pattern cast into every actuator casing uniquely identies the regulator as part of the Fisher® brand
Commercial Service Regulator family and assures you of the highest-quality engineering, performance, and support traditionally associated with Fisher, Francel, and Tartarini regulators. Visit www.shercommercialservice.com to access interactive applications.
Loading...