Emerson CF960CK 00, CF960WB 00, CF960BS 00 User Manual

0 (0)
Part No. F40BP72680001 Form No. BP7268-1
READ AND SAVE THESE INSTRUCTIONS
WINDJAMMER
®
Net Weight: 27.6 Lbs.
Ceiling Fan
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for thirty years from the date you purchased your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Company Do To Correct Problems:
Emerson will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or
blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan.
WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OF REMOVAL,
REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson
Company, 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center. You will be
responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan
should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:
Repairs by persons not authorized by Emerson Company,
Use of parts or accessories not authorized by Emerson Company,
Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
The original purchaser or user ceases to own the product, or
The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Company.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE
FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages
as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was
damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Model No.
CF960CK 00
CF960WB 00
CF960BS 00
®
Emerson
Ceiling Fans
- MODEL CF960 -
2
WARNING
!
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the
service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off
the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not
operate fan without blades.
2. All wiring must satisfy National and Local Electrical Codes. Use the National Electrical Code if
Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible
electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50
pounds. Use only U.L. outlet boxes listed as acceptable for fan support, and use the mounting
screws provided with the outlet box. Most outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified
electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade
clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental
contact with the fan blades.
6. The light fixture supplied with the ceiling fan is designed to use a long neck 75-watt (maximum)
halogen flood lamp. Do not install a lamp that exceeds 75-watts.
7. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do
not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not
specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any
accessories designated specifically for use with this product by Emerson. Substitution of parts or
accessories not designated for use with this product by Emerson could result in personal injury or
property damage.
WARNING: To Reduce the risk of personal injury, do not bend the blade flange when installing the
blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
DATE CODE:
The date code of this fan may be found on
the box, stamped in ink on a white label.
You should record this data above and keep
it in a safe place for future use.
1. Check to see that you have received the following
parts:
NOTE: If you are uncertain of part description,
refer to exploded view illustration.
a. Fan motor assembly
b. One light fixture assembly
c. Six fan blades
d. Six blade flanges
e. One ceiling cover
f. One hanger ball/downrod assembly
g. One hanger bracket
h. One coupling cover
i. One light fixture mounting plate
j. One PAR 30 75-watt halogen flood lamp
k. One light adapter plate
l. One loose parts bag containing:
1. Nineteen 3/16-24 x 5/16” slotted Phillips head
blade screws
2. Nineteen M5 flat washers
3. One large wood pendant
4. One small wood pendant
5. Two couplings
6. Thirteen 1/4-20 x 1/2” Phillips oval head
flange screws
7. Three wire connectors
8. Two threaded studs
9. Two #8 lockwashers
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
T ools Needed for Assembly
One Phillips head screwdriver One stepladder
One 1/4” blade screwdriver One wire stripper
Three wire connectors (supplied).
MA TERIALS
Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would
be a 3-conductor (2-wire with ground) of the following
size:
3
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is completed, place a
check mark in the box. This will insure that all steps have been completed and will be helpful in finding
your place should you be interrupted.
Before assembly your ceiling fan, refer to “Wiring Your
Ceiling Fan” section for proper method of wiring your
fan (page 6). If you feel you do not have enough wiring
knowledge or experience, have your fan installed by a
licensed electrician.
Do not install or use fan if any part is damaged or
missing. Call Toll-Free:
1-800-654-3545
This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Company. Substitution of parts or
accessories not designated for use with this product
by Emerson Company could result in personal injury
or property damage.
10. Two knurled knobs
11. One clevis pin
12. One hairpin clip
13. Four 5/32-32 x 5/16” Phillips flat head screws
14. Three 3/16-24 x 1/4” Phillips round head screws
15. One two-sided foam tape
NOTE: Place the parts from the loose parts bags
in a small container to keep them from being lost.
If any parts are missing, contact your local
retailer or catalog outlet for replacement before
proceeding.
LOOSE
PARTS
BAG
FAN MOTOR
ASSEMBLY
LIGHT FIXTURE
ASSEMBLY
BLADE
FLANGES
LIGHT FIXTURE
MOUNTING PLATE
COUPLING
COVER
CEILING
COVER
HANGER
BRACKET
HANGER BALL/
DOWNROD
ASSEMBLY
HALOGEN
FLOOD
LAMP
FAN
BLADES
LIGHT ADAPTER
PLATE
WARNING
!
WARNING
!
WARNING
!
5. Make sure the grommet is properly installed in the
coupling cover, then slide the coupling cover on
the downrod until it rests on the motor housing.
Place the ceiling cover over the downrod. Be sure
that the ceiling cover and the coupling cover are
both oriented correctly (Figure 4).
6. Reinstall the hanger ball (Figure 5) on the downrod
as follows. Route the three 80” motor leads through
the hanger ball. Position the pin through the two
holes in the downrod and align the hanger ball so the
pin is captured in the groove in the top of the hanger
ball. Pull the hanger ball up tight against the pin and
securely tighten the setscrew in the hanger ball.
A loose setscrew could create fan wobble.
Assembling and Hanging
the Ceiling Fan
1. Remove the fan motor assembly from the protec-
tive plastic bag and then carefully remove the foam
shipping material from between the fan motor and
the upper housing (Figure 1).
2. Place the fan motor assembly in the lower styro-
foam pad with the top of the motor facing up. The
lower styrofoam pad serves as a holder for the fan
motor assembly during the first stages of assembly.
3. Remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 2). Remove the pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in step 6.
4. Separate, untwist and unkink the three 80” motor
leads. Route the motor lead wires through the
downrod. Remove the upper setscrew from the
motor coupling. Align the clevis pin holes in the
downrod with the holes in the motor coupling.
Install the clevis pin and secure with the hairpin clip
(Figure 3). The clevis pin must go through the
holes in the motor coupling and the holes in the
downrod. Be sure to push the straight leg of the
hairpin clip through the hole near the end of the
clevis pin until the curved portion of the hairpin clip
snaps around the clevis pin. The hairpin clip must
be properly installed to prevent the clevis pin from
working loose. Pull on the downrod to make sure
the clevis pin is properly installed. Reinstall the
upper setscrew in the motor coupling (Figure 3).
Check that the two lower setscrews are tightened
securely.
NOTE: The setscrews must be properly installed
as described above, or fan wobble could result.
4
It is critical that the clevis pin in the motor coupling
is properly installed and the setscrews securely
tightened. Failure to verify that the pin and setscrews
are properly installed could result in the fan falling.
WARNING
!
PIN
SETSCREW
HANGER
BALL
DOWNROD
Figure 2
MOTOR COUPLING
HAIRPIN
CLIP
UPPER
SETSCREW
CLEVIS
PIN
DOWNROD
CLEVIS
PIN
LOWER
SETSCREW (2)
HAIRPIN
CLIP
MOTOR
COUPLING
UPPER
SETSCREW
CLEVIS PIN
Figure 3
CEILING
COVER
GROMMET
COUPLING
COVER
It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.
WARNING
!
Figure 4
REMOVE
FOAM SHIPPING MATERIAL
FAN MOTOR
HOUSING
FAN MOTOR
Figure 1
Loading...
+ 8 hidden pages