Emerson CF755BS05, CF755SCK05, CF755BZH05, CF755BC05, CF755SCB05 User Manual

...
READ AND SAVE THESE INSTRUCTIONS
Model No.
DESIGNER
CF755AB05 CF755AGW05 CF755AW05 CF755BC05 CF755BS05 CF755BQ05 CF755BZH05 CF755CK05
CF755SCB05 CF755ORB05 CF755PB05 CF755PW05 CF755SCK05 CF755TG05 CF755WB05 CF755WW05
CF755HTW05
Ceiling Fan
Owner's Manual
LIMITED WARRANTY
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson will refund the actual purchase price of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OR
REMOVAL, REINSTALLATION AND SHIPPING OF THE PRODUCT TO EMERSON ELECTRIC CO. How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson Electric Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsiblefor any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson Electric Co. REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Net Weight: 18.0 Lbs.
ENERGY STAR
Part No. F40BP73170000 Form No. BP7317
U.L. Model No.: CF755
WARNING
!
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring must be in accordance with the National Electrical Codes “ANSI/NFPA 70-1999” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.
DATE CODE:
The date code of this fan may be found on
the box, stamped in ink on a white label.
You should record this data above and keep
it in a safe place for future use.
2 U.L. Model No.: CF755
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
T ools Needed for Assembly
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
One Phillips head screwdriver One stepladder
50-100 ft. 12
One 1/4” blade screwdriver One wire stripper Three wire connectors (supplied).
WARNING
!
MA TERIALS
Wiring outlet box and box connectors must be of type required by the local code. The minimum wire would be a 3-conductor (2-wire with ground) of the following size:
Before assembly your ceiling fan, refer to section on proper method of wiring your fan (page 6). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.
Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is completed, place a check mark in the box. This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted.
WARNING
!
Do not install or use fan if any part is damaged or missing. Call Toll-Free:
1-800-654-3545
WARNING
!
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer or catalog outlet for replacement before proceeding.
2. Remove the fan assembly from the protective
plastic bag. Place the fan assembly into the upper foam pad with the bottom of the motor facing up.
The upper foam pad serves as a holder for the fan during the first stages of assembly.
1. Check to see that you have received the following parts:
NOTE: If you are uncertain of part description, refer to exploded view illustration.
a. Fan motor assembly b. One switch housing assembly c. Five fan blades d. One ceiling cover e. Five blade flanges f. One hanger ball/downrod assembly g. One hanger bracket h. One coupling cover i. One loose parts bag containing:
1. Sixteen M5 x 6 washer head blade screws
2. Sixteen blade washers
3. One M6 x 14 captive screw with lockwasher
4. One wood pendant
5. One coupling
6. Three wire connectors
7. Two threaded studs
8. Two knurled knobs
9. Two lockwashers
10. One clevis pin
11. One hairpin clip
BLADE FLANGES
CEILING COVER
LOOSE PARTS BAG
SWITCH CUP ASSEMBLY
FAN MOTOR ASSEMBLY
HANGER BALL/ DOWNROD ASSEMBLY
COUPLING COVER
FAN BLADES
HANGER BRACKET
3 U.L. Model No.: CF755
How to Put Your Ceiling
Fan Together
1. Remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in step 5.
PIN
DOWNROD
HANGER BALL
3. Make sure the grommet is properly installed in the coupling cover, then slide the coupling cover on the downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure that the ceiling cover and the coupling cover are both oriented correctly (Figure 3).
CEILING COVER
COUPLING COVER
Figure 1
SETSCREW
2. Separate, untwist and unkink the three 80” motor leads. Route the motor lead wires through the downrod. Remove the upper setscrew from the motor coupling. Align the clevis pin holes in the downrod with the holes in the motor coupling. Install the clevis pin and secure with the hairpin clip (Figure 2). The clevis pin must go through the holes in the motor coupling and the holes in the downrod. Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the downrod to make sure the clevis pin is properly installed. Reinstall the upper setscrew in the motor coupling. Check that the lower setscrew is tightened securely (Figure 2).
NOTE: The setscrews must be properly installed as described above, or fan wobble could result.
WARNING
!
It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.
Figure 3
4. Reinstall the hanger ball (Figure 4) on the downrod as follows. Route the three 80” motor leads through the hanger ball. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball. Pull the hanger ball up tight against the pin and securely tighten the setscrew in the hanger ball. A loose setscrew could create fan wobble.
WARNING
!
It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that the pin and setscrew are properly installed could result in the fan falling.
PIN
DOWNROD
HANGER BALL
SETSCREW
CLEVIS PIN
UPPER SETSCREW
Figure 2
CLEVIS PIN
MOTOR COUPLING
HAIRPIN CLIP
MOTOR COUPLING
DOWNROD
CLEVIS PIN
SETSCREW
HAIRPIN CLIP
SETSCREW
Figure 4
5.The fan comes with blue, black and white leads that
are 80” long. Before installing fan, measure up approximately 6 to 9-inches above top of hanger ball/downrod assembly. Cut off excess leads and strip back insulation 1/2-inch from end of leads.
6. Engage the connector of the switch housing assembly with the motor connector (Figure 5). The two connectors are keyed and color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connector latch closes properly.
7. Remove the three switch housing mounting screws (Figure 5) from the switch housing plate. Position the switch housing assembly on the switch housing plate and align the holes in the switch
4 U.L. Model No.: CF755
housing assembly with the holes in the plate. Secure the switch housing assembly by installing the three screws (Figure 6).
WARNING
!
To avoid possible fire or shock, do not pinch wires between the switch cup assembly and the switch cup plate.
WARNING
!
To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.
11. The blade flanges have an interlocking feature
that must be fully engaged before tightening the screw. Make sure all the flanges are properly engaged and then tighten the flange screws. If one of the flanges does not seat properly on the motor hub, loosen the adjacent flange screws, re­engage and reseat the flanges, then tighten the screws again.
SWITCH HOUSING CONNECTOR
MOTOR CONNECTOR
SWITCH HOUSING MOUNTING SCREW (3)
Figure 5
SWITCH HOUSING ASSEMBLY
MOUNTING SCREWS (3)
Figure 6
8. Turn fan assembly upside down in preparation for mounting fan blade assemblies.
9. Mount blade flanges to fan blades using three M5 x 6 washer head blade screws and three blade washers (Figure 7).
M5x6WASHER HEADBLADE SCREW (3)
BLADE WASHER (3)
BLADE ASSEMBLY
M6 x 14 CAPTIVE SCREWS WITH LOCKWASHERS
Figure 8
12. You have now completed the assembly of your new ceiling fan. You can now proceed with hanging and wiring your fan.
Electrical Requirements
Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.
WARNING
!
To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
FAN BLADE
BLADE FLANGE
Figure 7
NOTE: Take care not to scratch fan housing when installing blades.
NOTE: Remove and discard the four shipping spacers and screws from the motor hub.
10. Loosely attach one blade assembly to the motor
hub using two M6 x 14 captive screws with lockwashers. Make sure the screws are NOT tightened. (Figure 8.) Repeat this procedure for other four blade assemblies.
If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.
WARNING
!
Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING
!
To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.
5 U.L. Model No.: CF755
How to Hang Your
TAB
OUTLET
Ceiling Fan
WARNING
!
The fan must be hung with at least 7' of clearance from floor to blades (Figure 9).
CEILING
NOTE: CEILING COVER, SUPPLYWIRESAND FAN WIRES OMITTED FOR CLARITY.
Figure 11
OUTLET BOX
HANGER BRACKET
HANGER BALL/ DOWNROD ASSEMBLY
ATLEAST
7'
Figure 9
!
FLOOR
WARNING
The outlet box and joist must be securely mounted and capable of supporting at least 50 lbs. Use only a U.L. outlet box listed as “Acceptable for Fan Support”.
WARNING
!
To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
1.Securely attach the hanger bracket to the outlet box
using the two screws supplied with the outlet box. (Figure 10.)
BOX
How to Wire Your Ceiling Fan
If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
WARNING
!
To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.
1. Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger bracket to the grounding conductor of supply (this may be a bare wire or wire with green colored insulation). Securely connect wires with wire connectors supplied.
BLACK AND BLUE
GROUND WIRE
LISTED WIRE CONNECTOR (3)
FAN WIRES
NOTE: CEILING COVER OMITTED FOR CLARITY.
WHITE SUPPLY (NEUTRAL)
TWO SCREWS SUPPLIED WITH OUTLET BOX
HANGER BRACKET
Figure 10
2. Carefully lift the fan and seat the hanger ball/downrod assembly on the hanger bracket that was just attached to the outlet box (Figure 11). Be sure the groove in the ball is lined up with tab on the hanger bracket (Figure 10).
WARNING
!
Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wall board until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.
WARNING
!
Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.
WARNING
!
To avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket.
GREEN WIRE (GROUND) FROM HANGER BRACKET
Figure 12
GREEN WIRE (GROUND) FROM HANGER BALL
WHITE FAN WIRE
BLACK SUPPLY (HOT)
NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wiring.
2. Securely connect the fan motor white wire to the
supply white (neutral) wire using wire connector supplied (Figure 12). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure
12). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box.
WARNING
!
Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result.
6 U.L. Model No.: CF755
3. Screw the two threaded studs (supplied) into the tapped holes in the hanger bracket.
4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover (Figure 13).
5. Secure the ceiling cover in place by sliding lockwashers over the threaded studs and installing the two knurled knobs (supplied). (Figure 13). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch.
CEILING COVER
Using Your Ceiling Fan
1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box.
2. Check the operation of the fan by gently pulling on the pull chain switch.
3. All fans are shipped from the factory with the reversing switch positioned “down” to circulate air downward. If airflow is desired in opposite direction, turn your fan OFF and wait for the blades to stop turning, then slide the reversing switch to the “up” position, and turn fan on again.
4. The fan blades will turn in the opposite direction and reverse the airflow.
Your fan model is equipped with a 4-position, 3-speed pull chain switch. The operating sequence is as follows:
THREADED STUD
KNURLED KNOB
Figure 13
WARNING
!
To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.
LOCKWASHERS (2)
6. Cut the 3-speed switch pull chain to a desired length (optional). Connect the wood pendant (supplied) to the 3-speed switch pull chain by sliding the wooden pendant (small hole first) onto the pull chain. Attach the chain coupling to the end of the chain and allow the wooden pendant to fall down over the coupling.
Three-Speed
1st Pull—HIGH 2nd Pull—Medium 3rd Pull—Low
SPEED CONTROL SWITCH
REVERSIBLE SWITCH
4th Pull—OFF
Reverse Switch Information
Season Rotation Direction Switch Position
Summer Counter-Clockwise Down Winter Clockwise Up
7 U.L. Model No.: CF755
Energy Efficient Use of
Maintenance
Ceiling Fans
Ceiling fan performance and energy savings rely heavily on the proper installation and use of the ceiling fan. Here are a few tips to ensure quality and product performance.
Choosing the Appropriate Mounting Location.
Ceiling fans should be installed, or mounted, in the middle of the room and at least 7 feet above the floor and 18 inches from the walls. If ceiling height allows, install the fan 8 - 9 feet above the floor for optimal airflow. Consult your Emerson Retailer for optional mounting accessories.
Using the Ceiling Fan Year Round. In the summer, use the ceiling fan in the counter-clockwise direction. The airflow produced by the ceiling fan creates a wind-chill effect, making you "feel" cooler. Select a fan speed that provides a comfortable breeze, lower speeds consume less energy. In the winter, reverse the motor and operate the ceiling fan at low speed in the clockwise direction. This produces a gentle updraft, which forces warm air near the ceiling down into the occupied space. Remember to adjust your thermostat when using your ceiling fan - additional energy and dollar savings could be realized with this simple step!
Turn Off When Not in the Room. Ceiling fans cool people, not rooms. If the room is unoccupied, turn off the ceiling fan to save energy.
IMPORTANT CARE INSTRUCTIONS
for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.
WARNING
!
Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
Accessories
1. Ceiling Fan Light Kits (see store or catalog).
2. Ceiling Fan/Light Controls (see store or catalog).
3. Downrod Extension Kits (see store or catalog).
WARNING
!
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
WARNING
!
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.
8 U.L. Model No.: CF755
WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.
!
Trouble Shooting
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit
2. Loose power line connections to the fan, 2. Check line wire connections to fan and switch or loose switch wire connections in the wire connections in the switch housing. switch housing.
3. Reversing switch in neutral position. 3. Make sure reversing switch position is all the
2. Fan sounds noisy. 1. Blades not attached to fan. 1. Attach blades to fan before operating.
2. Loose screws in motor housing. 2. Check to make sure all screws in motor housing
3. Screws securing fan blade flanges to 3. Check to make sure the screws which attach motor hub are loose. the fan flanges to the motor hub are tight.
4. Wire connectors inside switch housing 4. Check to make sure wire connectors in switch rattling. housing are not rattling against each other or
5. Motor noise caused by solid-state 5. Some fan motors are sensitive to signals from variable speed control. Solid-State variable speed controls. If Solid-
6. Screws holding blades to flanges 6. Tighten screws securely. are loose.
3. Fan wobbles 1. Setscrew in motor coupling is loose. 1. Tighten both setscrews securely in the motor excessively. coupling.
2. Setscrew in hanger ball/downrod 2. Tighten the setscrew in the hanger ball/ assembly is loose. downrod assembly.
3. Screws securing fan blade flanges to 3. Check to be sure screws which attach the fan motor are loose. blade flanges to the motor are tight.
4. Fan blade flanges not seated properly. 4. Check to be sure the fan blade flanges seat
5. Hanger bracket and/or ceiling outlet 5. Tighten the hanger bracket screws to the outlet box is not securely fastened. box, and/or secure outlet box.
6. Fan blades out of balance. 6. Interchanging an adjacent (side-by-side) blade
breakers.
!
WARNING: Make sure main power is
turned OFF.
way to one side.
are snug (not over-tight).
against the interior wall of the switch housing.
!
WARNING: Make sure main power is
turned OFF.
State Control is used and motor noise results choose an alternative control method.
firmly and uniformly to the surface of the motor. If flanges are seated incorrectly, loosen the flange screws and retighten according to the procedure in the section on "How to Put Your Ceiling Fan Together".
pair can redistribute the weight and result in smoother operation.
9 U.L. Model No.: CF755
Repair Parts
2
13
19
1
15
4
16
17
7
9
3
5
20
6
12
14
8
11
10
18
10 U.L. Model No.: CF755
Repair Parts Listing
Key No. Description CF755AB05 CF755AGW05 CF755WB05 CF755BZH05 CF755PB05 CF755SCB05 CF755TG05 CF755BS05 CF755PW05
* Hanger Ball Assembly, 761655-3 761655-40 761655-20 761655-41 761655-2 761655-9 761655-13 761655-17 761655-22
Consisting of: 1 Hanger Bracket — 2 Hanger Ball — 3 Downrod
* Parts Bag Containing: 762997-1 762997-1 762997-1 762997-1 762997-4 762997-1 762997-1 762997-3 762997-1 4 Wire Connector (3) — 6 Pin, Clevis — 7 Clip, Hairpin — 8 Screw, M6 x 14 (1) — 9 Screw, M5 x 6 (16)
10 Wood Pendant — 15 Threaded Stud (2) — 16 Lockwasher (2) — 17 Knurled Knob (2) — 18 Coupling — 19 Blade Washer (16)
5 Canopy, Ceiling 760169-2 760169-43 760169-30 760169-44 760169-1 760169-24 760169-25 760169-15 760169-33
11 Wiring Harness 762993-1 762993-1 762993-1 762993-1 762993-4 762993-1 762993-1 762993-2 762993-1 12 Switch Housing 763151-AB 763151-AGW 763151-WB 763151-BZH 763151-PB 763151-SCB 763151-TG 763151-BS 763151-PW 13 Blade (set of 5) 761859-8 761859-32 761859-24 761859-31 761859-8 761859-5 761859-16 761859-30 761859-30 14 Flange (set of 5) 763154-AB 763154-AGW 763154-WB 763154-BZH 763154-PB 763154-SCB 763154-TG 763154-BS 763154-PW 20 Coupling Cover 762463-4 762463-18 762463-1 762463-17 762463-11 762463 762463-14 762463-8 762463-12
Owner's Manual BP7317 BP7317 BP7317 BP7317 BP7317 BP7317 BP7317 BP7317 BP7317
Key No. Description CF755HTW05 CF755WW05 CF755BQ05 CF755AW05 CF755CK05 CF755BC05 CF755ORB05 CF755SCK05
* Hanger Ball Assembly, 761655-12 761655 761655-19 761655-21 761655-23 761655-24 761655-32 761655-31
Consisting of: 1 Hanger Bracket — 2 Hanger Ball — 3 Downrod
* Parts Bag Containing: 762997 762997 762997-1 762997-2 762997 762997-1 762997-1 762997-1 4 Wire Connector (3) — 6 Pin, Clevis — 7 Clip, Hairpin — 8 Screw, M6 x 14 (1) — 9 Screw, M5 x 6 (16)
10 Wood Pendant — 15 Threaded Stud (2) — 16 Lockwasher (2) — 17 Knurled Knob (2) — 18 Coupling — 19 Blade Washer (16)
5 Canopy, Ceiling 760169-20 760169 760169-31 760169-32 760169-34 760169-35 760169-41 760169-42
11 Wiring Harness 762993-3 762993-3 762993-1 762993-3 762993-3 762993-1 762993-1 762993-1 12 Switch Housing 763151-HTW 763151-WW 763151-BQ 763151-AW 763151-CK 763151-BC 763151-ORB 763151-SCK 13 Blade (set of 5) 761859-6 761859-22 761859-18 761859-23 761859-27 761859-8 761859-29 761859-8 14 Flange (set of 5) 763154-HTW 763154-WW 763154-BQ 763154-AW 763154-CK 763154-BC 763154-ORB 763154-SCK 20 Coupling Cover 762463-9 762463-15 762463-3 762463-5 762463-2 762463-6 762463-16 762463-19
Owner's Manual BP7317 BP7317 BP7317 BP7317 BP7317 BP7317 BP7317 BP7317
Model No.
Model No.
Before discarding packaging material, be certain all
parts have been removed.
HOW TO ORDER REPAIR P ARTS
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION:
• PART NUMBER • PART DESCRIPTION
• NAME OF ITEM • MODEL NUMBER For repair parts, phone 1-800-654-3545.
11 U.L. Model No.: CF755
Air Comfort Products
DIVISION OF EMERSON ELECTRIC CO.
8100 W. Florissant • St. Louis, MO 63136
Part No. F40BP73170000 Printed in China 09/07 Form No. BP7317
U.L. Model No.: CF755
Loading...