Emerson BDS-40 User Manual

Monitoring For Business-Critical Continuity
Albér BDS-40
Comprehensive UPS Battery Diagnostic System
Albér BDS-40 Battery Monitoring System Is Built For Today’s UPS Battery Cabinet System Configurations
Designed and optimized for UPS systems using 12 volt sealed batteries, the Albér BDS-40 is designed to be mounted on top of the cabinet and uses custom cables with each connection point identified to the specific battery. Installation is quick and easy.
Each Albér BDS-40 unit will monitor all the batteries in one cabinet, up to 40 jars. Two different units are
. The
le
b
a
l
ai
v
a
Unit
is the central point where UPS-
plied power and communication
p
su
onnec
c
ons ar
ti
Albér B
e m
D
de. Each
a
S
-40 B
as
e
additional battery cabinet in the
stem may then use an
y
s
40 P
lus U
nit
, w
Albér B
e
ansf
h tr
c
hi
S-
D
rs the data
to the Base Unit for alarm and data
orage. Each Base Unit can manage
t
s
lus Units for a total of six
e P
v
o fi
p t
u battery cabinets. There is a choice of
tegral Ethernet network card
an in
p modem as standard.
-u
al
i
d/or a d
an
Easy To Use
’s BDS system makes
Albér hard-to-interpret data much more understandable and manageable. The Battery Monitor Data Manager Computer Software is included with every system. With the software you can program thresholds, identify problem batteries by making bar graphs turn red, triggering alarms and distribute alerts to e-mail lists as soon as abnormal conditions are detected. The report has built-in decision support that analyzes the data and provides suggestions for the best cause of action.
Early Warning For Battery Problems.
Like all Albér monitors, the Albér BDS­40 uses a patented Internal DC Resistance test method that bypasses the limitations of outdated AC based impedance testing. By tracking internal resistance, the system can predict and report failing conditions prior to complete failure. A time-to­go estimate algorithm, which uses
ischarge parameters and internal
d
e readings, assists in
anc
t
sis
e
r
aining battery life.
m
e
g r
tin
c
i
ed
r
p
The Albér BDS-40 continuously diagnoses all critical battery parameters such as cell voltage, overall string voltage, current and temperature. Automatic periodic tests of the batteries internal resistance will verify the operating integrity of the battery. An alarm sounds for any out­of-tolerance condition. If resistance values exceed set thresholds, the user can take proactive actions.
Albér technology by
Em
Emerson Network Power offers the latest in UPS battery monitoring technology with products by Albér — a leader in the field since 1972. Albér technologies by Emerson Network Power are designed to prevent battery failure, optimize useful battery life, reduce maintenance cost and increase safety.
Other features include:
n
The Albér BDS-40 scans pertinent battery parameters every 4 seconds, including total voltage, jar voltage, current and temperature.
n
Trend analysis provides the ability to analyze performance and aid in trouble shooting.
n
The unit displays real time data, automatically detecting discharges and providing alarm notification of any parameter outside limits.
n
Industry standard MODBUS protocol interfaces to third party building management systems via RS-232/USB
.
t
ne
r
d Ethe
an
n
Optional TCP/IP interface for network or Internet communication via MODBUS or SNMP.
n
stem comes complete with
y
h s
c
a
E the necessary cables to monitor
our battery.
y
n
Windows-based software included for real-time viewing, automatic data collection, data analysis, and report generating.
Emerson Network Power.com
Emerson Network Power.
The global leader in enabling
Business-Critical Continuity
.
AC Power Connectivity DC Power Embedded Computing Embedded Power
Monitoring
Outside Plant Power Switching & Controls Precision Cooling Racks & Integrated Cabinets Services Surge Protection
Liebert Corporation
1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX
Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy 39 049 9719 111 Phone 39 049 5841 257 FAX
Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 Gloucester Rd, Wanchai Hong Kong 852 25722201 Phone 852 28029250 FAX
liebert.com
24 x 7 Tech Support
800 222 5877 Phone 614 841 6755 (outside U.S.) monitoring@emerson.com email
Sealed batteries are sensitive to temperature and float voltage settings. Monitoring these conditions can considerably extend useful battery life.
An Albér battery monitor provides the user with detailed information, allowing for cost savings by optimizing useful battery life. Instead of waiting for an inevitable failure or replacing batteries prematurely to prevent problems, you can continue to utilize your batteries longer and with confidence by knowing their true internal condition.
It is essential to detect deterioration at an early stage to prevent catastrophic failures when dealing with 12 volt sealed batteries. This makes measurement technology the most important consideration when selecting a monitoring system. Other battery monitors’ internal ohmic readings become inconsistent as the UPS load varies because of variations in AC ripple on the battery. The Albér DC resistance test method is not influenced by ripple and thus provides data that is repeatable and reflects the true condition of the battery.
Albér BDS-40 Base Unit Specifications
Power
Less than 2.0 amps at 115 VAC ±10% 60Hz (for a maximum configuration of one Base Unit and five Plus Units with a total of 40 jars).
Configurations: 17, 20, 24, 25, 26, 27, 29, 30, 32, 33, 34, 35, 36, 38, and 40
Inputs
Remote alarm reset: User-supplied 12 to 32V signal. (Less than 50ma.) Momentarily applying voltage initiates the reset action.
Outputs
24 VAC power: For up to five Plus Units.
Alarm contacts: Two Form C: 2A at 30VDC.
Communication
Modbus protocol, ASCII to PC, and SNMP via Ethernet.
LAN port, RJ-45.
USB + RS-232 DB-9 connector for local PCV connection.
Local/LAN port, RS-232 DB-9 connector (rear panel).
, in
o line
lc
e
-11 T
RJ
Data Storage
SRAM (8 MB) non Holds up to one year’s worth of data.
Flash memory for firmware upgrades.
rating Environment
e
p
O
Temperature range: 5°C to 40°C (41°F to 104°F)
se only.
Indoor u
Packaging
Base unit: 19”W (482.6mm) x 16.2”D (411.5mm) x 7.8”H (198.1mm)
Plus unit: 19”W (482.6mm) x 16.2”D (411.5mm) x 6.1”H (155mm)
Parameters/Features
Number of cell channels: Up to six strings of 40, 12 volt jars.
t Range/Accuracy
n
e
m
e
sur
a
e
M
Cell voltage: 0 - 16V, 0.15% of reading ±4mV
Cell Resistance 0 - 32000 µΩ, 5% of reading ±5µΩ
age: 0 - 400V, 0.1% of reading ±.1V 0 - 600V, 0.2% of reading ±.5V
olt
ing v
tr
S
Discharge Current: 0 - 600V, 0.1% of reading ±6A 0 -1000V, 0.1% of reading ±10A
Float Current: 0 - 5000mA, ±0.1% of reading (Optional)
12-volt jars per string are supported.
(One for critical alarm; one for maintenance alarm.)
ternal modem (optional).
e memory for all configuration settings and test data.
l
ti
a
ol
v
rent transducer is required.
ur
C Transducer accuracy affects overall current reading accuracy.
Whi c r f
© 2008 Liebert Corporation. All rights reserved throughout the w
All names referred to are trademarks or registered trademarks o
® Li
SL-29202 (R05/08) Printed in USA
ecaution has been taken to ensure accuracy and
y pr
r
e
v
e e
l
ompleteness in this literature, Liebert Corporation assumes no
esponsibility, and disclaims all liability for damages resulting
om u
r
f the
ebert is a registered trademark of the Liebert Corporation.
formation or for any errors or omissions.
f this in
e o
s
orld. Specifications subject to change without notice.
ir respective owners.
usiness-Critical Continuity
B
r an
e
w
o
P are trademarks and service marks of Emerson Electric Co. ©2008 Emerson Electric Co.
rson Network Power logo
d the Eme
, Eme
rson Network
Loading...