MINI Retract-Lite: Concealed Emergency Lighting
MINI Retract-Lite: Concealed Emergency Lighting
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should
always be followed including the following:
“Mini”
READ AND FOLLOW ALL SAFETY
Unit
Equipment
INSTRUCTIONS
1. Do not use outdoors.
2. Do not let power supply cords touch hot surfaces.
3. Do not mount near gas or electric heaters.
4. Equipment should be mounted in locations and at heights where it
will not readily be subjected to tampering by unauthorized personnel.
5. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
6. Do not use this equipment for other than intended use.
7. All servicing should be performed by qualified service personnel.
SAVE THESE INSTRUCTIONS
Installation Instructions (Figure 1)
The emergency lighting unit comes with a U-shaped metal bracket, for
rigid mounting on wall studs and ceiling joists covered by drywall. This
bracket can be installed (retrofit) after the drywall is put in. For installation, the cable(s) for AC power supply (and DC remote) must be passed
near a wall stud or ceiling joist.
“U” Bracket Installation in the wall (Figures 2a, b, c)
1. Cut a rectangular opening (8-1/4 inch by 5-3/4 inch) in the drywall
next to the wall stud. The opening must have the short side along the
stud. Use the "U" bracket to mark the dimensions on th e drywall.
2. Pass the electrical cable(s) out through the hole.
3. Slide the “U” bracket in the hole: enter the flange side first then push
the other side to the stud.
4. Fix the “U” bracket on the stud with appropriate fasteners (not supplied).
5. Check that the four mounting screws are turned 2-3 threads in the
pem-studs.
“U” Bracket
Figure 1
8-1/4”
5-3/4”
Figure 2a
IMPORTANT: If the electrical cables pass in the wall from the ceiling,
make sure they are long enough to go out at least 3 to 4 feet through
the rectangular hole. This will ensure the flexible cables will loop and
access the bottom of the equipment about 1 ½ feet below the rectangular
hole.
Figure 2b
Emergi-Lite Tel: (888) 552-6467 ext. 547 or 255 Fax: (888) 867-1565 www.emergi-lite.com
08/08 750.1322 Rev. B
1/4
"U" Bracket Installation in an open ceiling
MINI Retract-Lite: Concealed Emergency Lighting
CAUTION:
It can only be installed in an open ceiling that can support this weight, or
an equivalent load pressure of minimum 33 lbs/sq.ft (160 kg/m2)
between two joists.
1. Cut a rectangular opening (8-1/4 inch by 5-3/4 inch) next to the ceiling
joist. The opening must have the short side along the joist. Use the "U"
bracket to mark the dimensions on the ceiling (Figures 2a, b, c).
CAUTION: Install a chain or "pencil rod" wires (provided by others) to
2.
a joist above the rectangular opening.
3. Slide the "U" bracket in the opening: enter the flange side first then
push the other side to the joist.
4. Fix the "U" bracket on the joist with appropriate fasteners (not supplied).
5. Check that the four mounting screws are turned 2-3 threads in the
pem-studs.
6. Pass the chain and electrical cable(s) out through the opening.
This unit equipment has a typical weight of 6.5 kg (14.5 lbs).
Equipment preparation (Figure 3)
1. Remove the cover of the transformer box.
2. If the unit requires DC connection: remove the knockout and install a
second conduit bushing (provided in the hardware kit).
3. Disengage the two hooks at the bottom of the housing.
4. For installation in open ceilings
necting the two metal housings to align them roughly along the same
axis.
: bend slightly the flexible bracket con-
Figure 2c
Cover
K.O. for
DC cable
Equipment installation in the wall (Figures 4 and 5)
1. Suspend the unit upside-down from the "U" bracket using the metal
hooks (see Figure 4). Do not hang the unit directly on the drywall edge
as this can damage the drywall.
2. Pass the electrical cable(s) through the bushings into the unit housing.
3. Connect the GREEN wire from the charger module and the back box
to the GROUND supply wire.
4. Connect the WHITE wire (labelled Neutral) to Neutral.
5. For 120VAC connect the BLACK wire (labelled 120VAC) from the unit
to Line.
6. For 277VAC connect the ORANGE wire (labelled 277VAC) from the
unit to Line.
7. For 347VAC connect the RED wire (labelled 347VAC) from the unit to
Line.
8. If there are any remote heads to be connected to the unit, connect the
RED wire (labelled L+) and the BLUE wire (labelled L-) to the load wires.
9. Make sure all unused wires are properly capped.
10.
CAUTION: failure to cap the wires may cause an unsafe condition.
1 1. If the equipment includes a battery, connect the battery positive wire
(labelled: "Connect battery positive terminal") to the battery or printed circuit board, as indicated by the second label.
12. Install the door on the housing and secure with the screw.
08/08 750.1322 Rev. B
2/4
Emergi-Lite Tel: (888) 552-6467 ext. 547 or 255 Fax: (888) 867-1565 www.emergi-lite.com
Figure 3
2 Hooks
Figure 4
2 Hooks
“U” Bracket
Electrical
connections