Model ES5M
ES5 Series - Designed to operate without distilled water, Self Contained or Direct Water Hookup, Stainless steel construction
Specifi cations:
120 volts 60HZ AC 1500 watts, max 12.5 amp
ES5 1800 series - 1800 watts, max 15 amps
Manual pump (push button) or timer operation
Closed generator
Half Pan size
Removable water drawer (self contained models)
Spring loaded adjustable hinge with 60° or 90° opening
Food Grid
ES5 1800 series - 1800 watts, max 15 amps
ES5 1800 series - 20% faster temperature recovery time
Quick connect fi ttings (direct hookup models)
This manual contains suffi cient information for installation of the EmberGlo Steamer in normal locations.
ES5 Series
Top Open / Half Pan Counter Top Steamer
ES5 Series - 1500W
ES5CTS: Timer Operation with Water Pan ES5M: Manual Operation with Water Pan ES5MT Manual Operation with Water Pan
and Specially Perforated Tortilla Food Pan
ES5PBS: Push Button Operation with Water Pan ES5PCS: Fixed Timer Operation with Water Pan
ES5PB: Push Button Operation with Direct Water Connect ES5CT: Timer Operation with Direct Water Connect ES5PC: Fixed Timer Operation with Direct Water Connect
ES5 1800 Series - 1800W
ES5M18: Manual Operation with Water Pan ES5CTS18: Timer Operation with Water Pan ES5PBS18: Push Button Operation with Water Pan
ES5CT18: Timer Operation with Direct Water Connect ES5PB18: Push Button Operation with Direct Water Connect
As of June 2013 the following steamers are no longer being manufactured - they are replaced with CT series steamers
ES5TS - now ES5CTS ES5T - now ES5CT ES5PTS - now Obsolete
In the United States, installation must conform with local codes.
PURCHASER: Retain these instructions for future use. Post in a prominent location near the steamer.
Warranty
See the back of this manual for warranty.
This warranty does not apply to damages resulting from accident, misuse, abuse or alteration.
No equipment may be returned without written authorization from EmberGlo (or Midco). Returned goods must be shipped prepaid to the factory.
Warranty card must be fi lled in and returned to EmberGlo (or Midco) to validate warranty.
SAFETY INFORMATION TERMS: The following terms are used to identify hazards, safety precaution of special notations and have standard meanings throughout this manual. They are printed in all capital letters using a bold type face as shown below, and preceded by the exclamation mark symbol. When you see the safety alert symbol and one of the safety information terms as shown below, be aware of the hazard potential.
EmberGlo
A Div of Midco® International Inc.
4140 West Victoria Street Chicago, Illinois 60646 toll free 866.705.0514 tel 773.604.8700 fax 866.580.8700 web www.emberglo.com
e-mail sales@emberglo.com
DANGER: Identifi es the most serious hazards which will result in severe personal injury or death. WARNING: Signifi es a hazard that could result in personal injury or death. CAUTION: Identifi es unsafe practices which would result in minor personal injury or product and property damage.
As an ISO 9001:2008 certifi ed company, we proudly design, manufacture and assemble our products in Chicago, Illinois, USA.
CAUTION: Cooking equipment should be used in an environment protected by an automatic fi re suppression system. Consult the National Fire Protection Association NFPA Code 96 or the latest edition of Standards for Installation of Equipment for Removal of Smoke and Grease-Laden Vapors From Commercial Cooking Equipment.
WARNING: Improper installation, adjustment,
alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
AVOID ERROR IN PARTS SELECTION. When ordering use complete EMBERGLO Part Number and Description. Furnish Model Number, Bill of Material Number and Serial Number (if available) from the specifi cation plate found on the product. IMPORTANT: Availability of parts as well as specifi cations are subject to change without notice. Please consult factory for item availability.
Quality Designed for Proven Performance
U
517
8449 96
L
Printed in USA
®
Page 2
ES5 Series - Installation
Installation
MADE in the USA
In the United States, wiring must conform to local codes, or in the absence of local codes, to the National Electrical code ANSI/NFPA No. 70-latest edition. In Canada, wiring must conform to local codes, or in the absence of local codes, to Canadian Electrical Code Part 1, CSA Standard
C22.1.
1. All ES5 Models: Locate on level surface and plug power cord into 120 volt, single phase 60Hz.
grounded outlet.
2. ES5M, ES5M18, ES5MT, ES5CTS, ES5CTS18, ES5PBS & ES5PCS: Fill water pan by pulling
water pan out to stop position and fi ll with cold water to top of baffl es, then close drawer.
3. ES5PB, ES5PB18, ES5CT, ES5CT18, & ES5PC: Connect water hose assembly to water
supply system. The supply end has 1/8″ female pipe fi tting and should be attached down stream to a shut-off valve. Steamer end of hose has a quick connect fi tting which snaps onto mating fi tting on steamer. This fi tting has an automatic shut-off valve that allows steamer to be disconnected without shutting off water supply. After connecting, turn on water and check for leaks.
4. EmberGlo Steamers do not require a separate hood for vapor produced during operation according to the Uniform Mechanical Codes per the International Conference of Building Offi cials Code. And there are no requirements in NSF Standard 4 (2006e) for steamers to
have ventilation.
5. Lid Angle Adjustment: To adjust the angle of the lid to 60° or 90°
1. With the lid closed, loosen and remove slotted screw. Set aside.
2. Remove lid stop by sliding it up and away from the steamer.
3. Adjust lid stop for desired position (60° or 90° open) and place on steamer.
4. Insert and tighten slotted screw. See Figure 1a, 1b and Figure 1c for orientation of lid stop. Factory default setting is 60°.
1
Figure 1c
1
90°
60°
Operation
2
2
Item # Part # Description
1 HW1-099 #8-32 X 5/16″ Slotted Pan Head Screw 18ss 2 1421-21 Lid Stop
Figure 1a
Back of ES Series Steamer
60° Opening Position
__________________________________________
General Instructions for Operation. For operation tips and recommendations see below. Before Using: (See Figure 2 for locations of buttons and switches)
1. Remove the protective plastic covering before using.
2. Steamers with self contained water drawers: If there is a water drawer open and fi ll reservoir
with water.
3. Steamers with direct hookup water supply: If the steamer is a direct hookup connect to a
water supply
4. Plug into 120V AC outlet.
5. Push power switch to the ON position (light on) and allow approximately 15-20 minutes to reach
operating temperature.
6. Test to make sure unit will generate steam (except the ES5PCS and ES5PC).
7. For ES5CT, ES5CT18, ES5CTS & ES5CTS18 steamers: Switch the Cycle/Manual switch to
the manual mode.
EmberGlo A Division of Midco International Inc
Back of ES Series Steamer
Lid Stop Reversed
90° Opening Position
2
Figure 1b
8449 96
Page 3
ES5 Series - Operation
8. Press the round Steam button several times to remove the air from the system, you will notice it will start to steam. The Steamer is now ready to use.
General Operating Instructions: (See Figure 2 for locations of buttons and switches on timer models)
1. Open lid, place food on grid and close lid.
2. ES5M, ES5M18 & ES5MT: Press handle until it stops - then release. See Heating and Cooking Guide - 8474-75S for suggested number of operations or “shots” (a shot is one press
of pump handle). ES5PB, ES5PB18, ES5PBS & ES5PBS18: Push round button momentarily for each operation. Do not hold button more than one second.
Note: After installation, operate several times until the water hose fi lls with water.
ES5CT, ES5CT18, ES5CTS & ES5CTS18: (see Timer/Manual Operating Instructions below)
Operate the same as ES5PB & ES5PB18 above, or follow directions on label on front of unit which will automatically deliver three shots per minute for time set. At end of cooking time, READY light will come ON and signal will sound. Turn toggle switch to OFF to silence signal. ES5PC & ES5PCS (Preset Timer Models): Operates by pressing the round button to start thecook cycle. At the end of the cook cycle the READY light will come ON and the signal will sound.
3. Open lid and remove food.
4. For effi ciency and safety purposes, keep lid closed when not in use. This keeps the food pan hot and reduces condensation in the steam chamber.
5. To shut off , push power switch to OFF position.
Timer Operating Instructions with ES5CT, ES5CT18, ES5CTS & ES5CTS18 timer steamers: (See Figure 2 for locations of buttons and switches)
1. ES5CTS & ES5CTS18: Fill the water reservoir at the beginning of each day. During use check the water reservoir periodically.
2. Turn unit on, the Ready indicator will light.
3. Allow the steamer warm up for about 10 minutes.
4. Move the Cycle/Manual switch to the cycle mode.
5. Lift the lid and place product on the rack, close lid.
6. Rotate the timer dial to the desired cooking time.
7. Press the round Steam button to start the cooking cycle (the ready light will go out). Move the buzzer toggle switch to on position. Note: The steamer will automatically generate steam about every 15/20 seconds.
8. After the cycle has been completed, the Ready indicator light will turn on and the buzzer will sound indicating the cycle is done. Use the buzzer switch to turn off the buzzer.
9. Open the lid, carefully remove the very hot product.
10. The steamer is now ready for another cycle.
Operation
Continued
Manual Operating Instructions with a ES5CT, ES5CT18, ES5CTS & ES5CTS18:
1. Move the “Cycle/Manual” switch to the “Manual” mode.
2. Depress Round Steam push button approximately 1 second. Note: Excessive pressing of the steam button will fl ood the steam chamber.
1 65432
Item # Description
1. Steam Button - starts cycle timer or for manual steaming
2. Cycle/Manual Switch ­ Cycle is for position for timer usage Manual is for push button steaming
3. Cycle Timer - used to adjust cycle time
4. Signal Switch - turns on/off ‘Cycle Done’ buzzer
5. Ready Light - lights at the end of cycle time
6. Power Switch - turn on before usage for approximately 10 minutes to warm steamer
Figure 2
ES5CT, ES5CT18, ES5CTS & ES5CTS18 Steamers - Front Panel
8449 96
EmberGlo A Division of Midco International Inc
3
Page 4
L1 NLGND
BLK
BLK
WHT
THERMOSTAT
OPEN @ 350°F
THERMAL
FUSE
HEATING
ELEMENT
1500 Watts
(OPT - 1800 Watts)
120V / 60Hz
WHT
GRN
BLK
BLK
WHT
BLK
PILOT
ON / OFF
R
WIRING DIAGRAM
HEATING
ELEMENT
BLK
HEATING
ELEMENT
THERMAL
FUSE
BLK
BLK
GRN
THERMOSTAT
WHT
WHT
LINE CORD
ON / OFF
PILOT
BLK
BLK
SCHEMATIC
ES5M, ES5M18 & ES5MT
FRONT PANEL CHASSIS
L1 NLGND
BLK
BLK
WHT
THERMOSTAT
OPEN @ 350°F
THERMAL
FUSE
HEATING
ELEMENT
1500 Watts
(OPT - 1800 Watts)
120V / 60Hz
WHT
GRN
BLK
BLK
WHT
BLK
PILOT
ON / OFF
R
PUSH
BUTTON
NC NO
COM
SOLENOID
VALVE
S
BLK
WHT
BLK
FRONT PANEL CHASSIS
SOLENOID
VALVE
THERMOSTAT
THERMAL
FUSE
HEATING ELEMENT
PUSH
BUTTON
PILOT
ON / OFF
HEATING
ELEMENT
LINE CORD
ES5PB & ES5PB18
WIRING DIAGRAMSCHEMATIC
FRONT PANEL CHASSIS
PUMP
THERMOSTAT
THERMAL
FUSE
HEATING ELEMENT
PUSH
BUTTON
PILOT
ON / OFF
HEATING
ELEMENT
LINE CORD
ES5PBS & ES5PBS18
WIRING DIAGRAM
L1 NLGND
BLK
BLK
WHT
THERMOSTAT
OPEN @ 350°F
THERMAL
FUSE
HEATING
ELEMENT
1500 Watts
(OPT - 1800 Watts)
120V / 60Hz
WHT
GRN
BLK
BLK
WHT
BLK
PILOT
ON / OFF
R
PUSH
BUTTON
NC NO
COM
PUMP
P
BLK
WHT
BLK
SCHEMATIC
ES5 Series - Schematic & Wiring Diagrams
4
Wiring Diagrams for ES5 Series Steamers - ES5M, ES5M18, ES5MT, ES5PB, ES5PB18, ES5PBS & ES5PBS18
Note: ES5 1800 Series Steamers have an 1800 watt heating element
EmberGlo A Division of Midco International Inc
Figure 3A
8449 96
Page 5
ES5 Series - Schematic & Wiring Diagrams
WIRING DIAGRAM
HEATING
ELEMENT
CHASSIS
MANUAL CYCLE
FRONT PANEL
CYCLE / MANUAL
PUSH
BUTTON
BLK
COM
BLK
ON / OFF
PILOT
SWITCH
BLU
NC
BLK
NO
CYCLE
TIMER
PUSH
BUTTON
ES5CT, ES5CT18, ES5CTS & ES5CTS18
SCHEMATIC
THERMOSTAT
OPEN @ 350°F
RED
CYCLE
MANUAL
BLU
SHOT TIMER
8406-64
EXT RES
20 MIN / 1 MEG
5
BLK
RED
BLK
9
BLK
INITIATE
COM
AC
HOT
2
CYCLE
MANUAL
THERMAL
FUSE
8406-92
OFF
20 SEC
2M OHMS
1
LOAD
6
NO
NC
AC
NEUT
3
PUMP /
SOLENOID
AC
HOT
2
7
ORN
8
1
EXT RES
L1
ON
0.2 SEC
22K OHMS
AC
NEUT
3
READY LIGHT
RED
SIGNAL SW
RED
THERMAL
FUSE
SHOT
TIMER
120 VAC
GND
HEATING
ELEMENT
1500 Watts
(OPT - 1800 Watts)
PUMP /
SOLENOID
P/S
CYCLE
TIMER
8406-92
BUZZER
YEL
WHT
BLU
YEL
SIGNAL
NL
HEATING
ELEMENT
SW
LINE CORD
BUZZER
ON / OFF
PILOT
READY
LIGHT
AIROTRONICS TIMERS
CYCLE
TIMER
ON
54
OFF
7
6
+ 3
INPUT
- 2
LOAD
1
ACP TIMERS
CYCLE
TIMER
5
4
470K OHMS
470K OHMS
LOAD
OFF
ON
76
220K OHMS
22K OHMS
- 2
INPUT
+ 3
220K OHMS
220K OHMS
THERMOSTAT
1411-90
1
NC
8
NO
9
COM
AC
2
HOT
NEUT
3
NO
1
NC
COM
SHOT
TIMER
150 SEC
580K OHMS
690K OHMS
0.2 SEC
22K OHMS
SHOT
TIMER
INITIATE
-
TIME
OFF
10 SEC
ON
6
7
5
INITIATE
3
INPUT
-
54
CHASSIS
FRONT PANEL
NOTE: for Old Style Timer Steamers, ES5T & ES5TS wiring diagrams refer to 8449-96B
Wiring Diagrams for ES5 Series Steamers - ES5CT, ES5CT18, ES5CTS & ES5CTS18 with Mechanical Timer
Note: ES5 1800 Series Steamers have an 1800 watt heating element
8449 96
Figure 3B
EmberGlo A Division of Midco International Inc
5
Page 6
ES5 Series - Operation and Maintenence
Operation Continued
IMPORTANT: KEEP LID CLOSED WHEN NOT IN USE. This keeps the food pan hot and reduces condensation in the steam chamber. When steamer is fi rst installed, or when reconnecting water hose, operate STEAM button several times to purge air from lines.
General Tips and Recommendations for Operation.
To sustain optimum cooking performance: It is important to maintain the correct amount of steam generated. Either holding the manual pump (ES5M, ES5M18, & ES5MT) or pressing the button (ES5PB, ES5PB18 or ES5PBS, ES5PBS18) too long will fl ood the generator with too much water. On the other hand not holding the pump (ES5M & ES5M18) or pressing the button (ES5PB, ES5PB18, ES5PBS & ES5PBS18) long enough and not spraying enough water will not produce enough steam on the generator to properly cook the food in the desired time.
Recommended pumping and button pressing times for proper water levels in the generator: ES5M, ES5M18 & ES5MT - It is recommended that the user pump the handle two to three
times every 20 to 30 seconds. If it is pumped more times or if the user does not wait long enough between pumps, the generator will fl ood. Also, if it is pumped only once every minute there will not be enough water in the generator to produce the correct amount of steam to sustain optimal cooking performance.
ES5PB, ES5PB18, ES5PBS & ES5PBS18 - It is important to hold the button in for 3 seconds. If the button is held too long, the generator will fl ood. If the button is held too short of a time, not enough water will be sprayed onto the generator to create enough cooking steam. See below (next paragraph) for recommendations on how to know this.
Recommended Procedure for Understanding the Amount of Steam Generated in both the Manual and Push Button Types of Steamers:
Maintenance ­As Required
1. On a cool steamer take the food rack and food pan out of the steamer so that the generator and water nozzle can be seen.
2. Warm up the unit for 10 to 15 minutes.
3. ES5M ES5M18 & ES5MT - Push the manual lever two to three times ES5PB, ES5PB18, ES5PBS & ES5PBS18 - Push the button long enough to spray water on the generator surface.
4. Watch the water turn into steam. All of the water should evaporate in approximately 20 to 30 seconds.
By pumping the manual lever (ES5M, ES5M18 & ES5MT) or pushing the button (ES5PB, ES5PB18, ES5PBS &ES5PBS18) and watching the time it takes to evaporate the water, the user will learn how to reach the optimal cooking results, whether by pushing the button in or pumping the manual lever. Timer Type of Steamers - (ES5CTS, ES5CTS18, ES5CT & ES5CT18) - this timing is internally set by the manufacturer to obtain the optimum cooking steam cycle. __________________________________________
Maintenance Food Pan and Grid on all models should be removed and washed with a detergent or run through a
dishwasher. WARNING: Under no circumstances should the entire steamer be run through a
dishwasher. If any of the switches or components get wet they can malfunction. Never try to use a device that has been wet— replace it. WARNING: Perform all maintenance when the unit is cool.
Exterior of unit should be wiped with a damp cloth or cleaned with a stainless steel cleaner. Water Pan on ES5M, ES5M18, ES5MT, ES5CT, ES5CT18, ES5CTS, ES5CTS18, ES5PB, ES5PB18, ES5PBS & ES5PBS18 may be removed for cleaning by pulling out to stop position; lift
front of steamer about 3″ to clear pump and pull pan all the way out. To replace, lift front of steamer about 3″, slide pan in pan track until it is about 2″ from closed position, then lower steamer front and push pan completely in. __________________________________________
Maintenance ­Daily
Generator: The cavity in the generator may accumulate lime and is cleaned by scraping or wire brushing. Do not remove all of this deposit since a thin coating improves steaming. Water Nozzle: The water nozzle, the round cap in front center of generator, may be pulled out for cleaning. Clean small holes and inside of tube with spring clip Water Inlet: If the tube through generator is limed, remove plug at bottom and push lime out with a wire or small rod.
6
EmberGlo A Division of Midco International Inc
provided in the tube.
8449 96
Page 7
ES5 Series - Manintenance and Service
Strainers:
ES5M, ES5M18 & ES5MT: Strainer is in bottom of pump. Remove wire ring, then strainer
wash and replace. ES5CTS, ES5CTS18, ES5PBS & ES5PBS18: Strainer is located in front center of bottom. Slip strainer off Tube, wash and replace. ES5PB, ES5PB18 ES5CT & ES5CT18: To wash strainer located in hose:
1. Remove hose.
2. Remove quick connect fi tting.
3. Reverse hose (connect steamer end to supply valve). Drain into sink or bucket.
4. Run water through hose to clean.
5. Return to original connections. There is a strainer in inlet of solenoid valve that normally does not require cleaning but under extreme conditions may have to be removed and cleaned. __________________________________________
Service
DANGER: Before attempting service, unplug power cord.
We recommend any service be done by qualifi ed service personnel. Refer to separate Parts List for parts identifi cation and assembly guide.
1. All electrical components are contained in enclosure behind switch panel. For access, remove
sloping front and switch panel.
2. ES5M, ES5M18 & ES5MT pump is easily removed for service or replacement. Disconnect
water line (under steamer) from pump, open electric enclosure, disconnect linkage and remove two screws holding pump.
3. To remove ES5CTS, ES5CTS18, ES5PBS & ES5PBS18 pump:
A. Disconnect electric wires from terminals. B. Disconnect discharge hose from pump. C. Remove two screws through bottom of steamer holding pump bracket. D. Lift pump out.
4. To adjust lid, loosen screws in lower hinge. With lid closed, tighten screws.
5. Thermostat is set to control temperature from 350° to 375°, and we suggest replacement if off
calibration. Thermostat may be removed by:
A. Removing electric enclosure covers and switch panel. B. Removing wires from thermostat terminals. C. Removing two screws holding thermostat. D. Pull capillary straight out to remove bulb.
CAUTION: Capillary tube is critical and care should be taken not to “kink”.
6. f water nozzle should clog with lime, remove by lifting up then clean small holes with paper clip
or similar tool. Lime inside tube is removed by fl exing tube, then shaking or washing out lime.
7. The water inlet is cleaned by removing plug at bottom and pushing lime out with wire or rod.
8. The main timer controls the cooking time and the shot timer delivers a measured amount of
water to produce steam every 20 seconds. If defective, replace (attempted service may aff ect timing).
Maintenance ­Daily Continued
Service
DANGER: Read and understand this bulletin thoroughly before starting any troubleshooting. An inadvertent service error could result in severe personal injury or death. Only a trained experienced service technician should attempt any repair procedure.
Qualifi ed service agencies are available at most locations—Refer to EmberGlo listing of Authorized Service Agencies included in Standard Equipment Catalog. Important: Defective wiring or loose connections can simulate the defects outlined below. Check associated wiring before replacing a component. __________________________________________
8449 96
EmberGlo A Division of Midco International Inc
7
Page 8
ES5 Series -Trouble Shooting
Trouble Shooting
1. Unit Does Not Heat Switch On, Light Out
2. Unit Does Not Heat Switch On, Light On
3. Unit Heats Switch on, Light Out.
4. Unit Heats Up, But Does Not Steam— No Water Evident on, Light Out.
5. Unit Floods— Switch On
6. Unit Works— Ready Light Inoperative
1.
A. Confi rm electric cord is securely plugged in. B. Confi rm receptacle is energized—reset breaker or repair house wiring.
WARNING: The following checks thru 7.A.1. should be done with electric cord
removed from receptacle.
C. Confi rm continuity in 3-conductor cord—replace if defective. D. Confi rm continuity in single pole, single throw Power Switch (the two adjacent terminals are switch terminals and the remote terminal is a tie-terminal). Replace if defective.
______________
2.
A. Confi rm continuity of Thermostat—replace if defective. B. Confi rm continuity of Heating Element—replace Steam Generator Casting if defective. C. Confi rm Thermal cutoff .
______________
3.
A. Defective light in switch— replace entire switch.
______________
4.
A. All Models: Clogged water nozzle, water inlet or strainers—check and clean as required, see Maintenance and Service sections. B. Models ES5M, ES5M18, ES5MT, ES5CTS, ES5CTS18, ES5PBS & ES5PBS18: Water pan empty—fi ll pan. C. Model ES5M & ES5M18: Confi rm pump is operative—check valves—inlet hose must not leak.See Service section. Rebuild or replace as required. D. Models ES5PB, ES5PB18, ES5CT & ES5CT18:
1. Confi rm Water Shut-Off Valve is on and Water Hose Assembly is properly hooked up. Refer to #3 from the Installation section page 2. A quick way to confi rm water line is operational is to disconnect Water Hose at quick disconnect fi tting and push a small probe into quick disconnect fi tting—water should fl ow freely.
2. Confi rm continuity of Water Solenoid Valve—replace if defective. E. Models ES5CT, ES5CT18, ES5PB, ES5PB18, ES5PBS, ES5PBS18, ES5CTS & ES5CT18: Confi rm continuity of Steam Push Button Switch when depressed—replace if defective. F. Models ES5CTS, ES5CTS18, ES5PBS & ES5PBS18:
1. Confi rm continuity of Oscillating Pump—replace if defective.
2. Confi rm integrity of hoses and fi ttings. Any and all leakage must be eliminated.
______________
5.
A. Models ES5CT, ES5CT18, ES5PB & ES5PB18: Water Solenoid Valve seat dirty—clean or replace as required.
______________
6.
A. Models ES5CT, ES5CT18, ES5CTS & ES5CTS18: Confi rm continuity of light replace if defective.
______________ __________________________________________
8
EmberGlo A Division of Midco International Inc
8449 96
Page 9
Heating and Cooking Guide
These suggestions are made only to help the operator get started. Since each location will have diff erent portions and diff erent requirements, each operator must determine his own operation habits. Please remember that the steamer conserves its steam in the drawer and therefore does not often need repeated shots. The main exception is when frozen product must be defrosted.
If a product is at room temperature or refrigerated, start with 2 shots. This ensures that the food pan is full of steam.
If a product is frozen, start with 3 shots because condensation on the cold product eliminates the steam quickly.
Breads Refrigerated Frozen
Bread 1 to 2 shots of steam 2 min
Bagels 1 to 2 min 3 to 4 min
Croissant 15 seconds
Muffi n 1-2 shots of steam
Pastries 1 to 2 min 3 to 4 min
Tamales 5 min 10 min
Tortillas 1 shot of steam 10 seconds
Eggs
Soft Boiled 6 min
Poached 3 min
Scrambled
(dz) 5 min
Meat
Bratwurst 8 min 16 min
Breakfast sausage 8 min 14 min
Chicken breast
Chicken breast
Deli meats 2 to 3 min
Hamburger
Hot dogs 4 min 8 min
Italian sausage 4 min 8 min
(precooked) 10 min 18 min
Ribs
(lg) 15 min 25 to 30 min
(precooked) 5 min 15 min
(precooked) 4 min 4 min
Noodles and Rice
Macaroni
Egg Noodles
Rice
Spaghetti
(2 qt. cooked, 1 pt. water, 2 oz. oil) 5 min
(2 qt. cooked, 1 pt. water, 2 oz. oil) 6 to 7 min
(precooked) 5 min 8 to 10 min
(2 qt. cooked, 1 pt. water) 5 min
Vegetables Refrigerated Frozen
Artichokes 25 to 30 min 50 min
Asparagus 10 min 14 min
Brussels 15 min 18 min
Broccoli 10 min 12 min
Carrots sliced 4 min 8 min
Carrots whole baby
Caulifl ower 12 min 16 min
Corn on the cob 3 min 5 min
Fennel 10 min
Green beans 4 min 8 min
Pea pods 6 min 9 min
Peas 5 min 8 min
Potatoes 8 whole
Potatoes mashed
Squash, Acorn 4
Squash, Zucchini -sliced frozen
(3 oz each) 20 min
(2 qt) 8 min
(8 oz each) 12 to 20 min
Seafood
Large clams 4 min 8 min
King crab 8 min 12 min
Snow crab 6 min 10 min
Fish fi lets 6 min 8 to 10 min
Lobster 8 oz Tails 8 min 14 to 16 min
Scallops 5 min 8 to 10 min
Shrimp 4 min 6 min
Cooking
Instructions
(2 lb) 15 to 20 min
(1 lb) 10 Min
8449 96
EmberGlo A Division of Midco International Inc
9
Page 10
ISO
9001
C
O
M
P
A
N
Y
R
E
G
I
S
T
E
R
E
D
Warranty
Keep for your records
Gas Broiler Electric Broiler Steamer
MADE in the USA
Model Number
Serial Number
Installation Date
Purchased from - Name:
Address
City, State, Zip
TO VALIDATE WARRANTY:
FILL OUT THE FORM ON THE LAST PAGES AND RETURN TO EMBERGLO
®
International Inc Limited Warranty Policy Exclusions Terms, Customer Requirements and Instructions
Midco
All claims should be fi led through Warranty Central. Call factory for information (773 604 8700)
Only Authorized Service Providers are authorized to provide Limited Warranty service on all EmberGlo Inc., food equipment as described under and Midco® International Limited Warranty Policy. A list of providers can be found on our web site: www.emberglo.com Provisions: In lieu of an implied warranty, all repairs and replacement parts furnished under our Limited Warranty shall be f.o.b. point of distribution, but the owner must pay the necessary freight, delivery and labor costs involved when required. Any Federal, State or Local taxes are also extra. This Limited Warranty is eff ective for a period of one year from date of installation. EmberGlo Electric Food Preparation Equipment manufactured by Midco International, sold under the EmberGlo® trademark, are guaranteed to be free from defect in material and workmanship under normal use and service for a period of 1 (one) year after the date of original installation. Midco’s obligation under this Limited Warranty Policy shall be limited to repairing or replacing, at our option, any part of said equipment which Midco examination shall disclose to its satisfaction to be thus defective. Exclusions: This Limited Warranty Policy does not apply to damages resulting from accident, misuse, abuse or alteration, nor does it apply to limed steam generators, nor does it apply to any consequential damages. Most geographical areas require the use of distilled or demineralized water. Tap water is permissible only with ES Series Steamers. Nor does it apply to Barbriq’s broilers. Midco’s obligation will be the replacement of the product or parts removed. Terms: Under the terms of this Limited Warranty Policy, models considered portable (devices with cords and plug caps such as EmberGlo Steamers) must be taken or returned to the nearest service provider, transportation prepaid, returned transportation collect. Non-portable units with permanent wiring will be serviced on the customer’s premises. Under these terms, Midco agrees, within the terms of this Limited Warranty period, to make all repairs at no charge by the authorized service provider. Labor and mileage charges submitted by any other provider not authorized will be the responsibility of the customer. Customer Requirements: All charges related to repairs made one (1) year after the date of original installation, during the Limited Warranty period will be the responsibility of the customer. The product registration information is located on the product I.D. plate.
Warranty
®
, a Division of Midco® International
®
Char Broilers and EmberGlo®
®
, briquettes, or rods used in gas
If a part is defective due to workmanship or materials and is removed from the product within the applicable warranty period and returned to Midco in accordance with the following procedure described, Midco will, at its option, either repair or replace the part.
Call the factory for Instructions on returned goods.
No equipment may be returned without written authorization from MIDCO. Returned goods must be shipped prepaid to the factory.
WARNING: Improper installation and use of this product could result in personal or property injury.
EmberGlo A Division of Midco International - 4140 West Victoria Street - Chicago, Illinois 60646
toll free: 866 705 0515 - tel: 773.604.8700 - fax: 866.580.8700 - web: www.emberglo.com - e-mail: sales@emberglo.com
10
EmberGlo A Division of Midco International Inc
517
8449 96
Printed in USA
Page 11
Warranty
Midco® International Inc Limited Warranty Policy
Exclusions Terms, Customer Requirements and Instructions
All claims should be fi led through Warranty Central. Call factory for information (866 705 0514) Fill out form and fax to 866 580 8700 or copy and mail to: EmberGlo 4140 West Victoria Street Chicago, Illinois 60646
Date of Purchase
End User Name
Company Name
Street & Apt. No.
City, State, Zip
E-mail Address
Web Address
Div of Midco International Inc
Warranty
Telephone
Fax
Steamer Gas Broiler Electric Broiler
Model Number
Serial Number
Installation Date
Purchased from - Name:
Address
City, State, Zip
8449 96
EmberGlo A Division of Midco International Inc
11
Page 12
EmberGlo Div of Midco International Inc.
ISO
9001
C
O
M
P
A
N
Y
R
E
G
I
S
T
E
R
E
D
Attn: Warranty Department
4140 West Victoria Street
Chicago, Illinois 60646
FOLD LINE
PLACE STAMP HERE
FOLD LINE
toll free: 866 705 0515 - tel: 773.604.8700 - fax: 866.580.8700 - web: www.emberglo.com - e-mail: sales@emberglo.com
EmberGlo A Division of Midco International - 4140 West Victoria Street - Chicago, Illinois 60646
517
8449 96
Printed in USA
Loading...