Emberglo ES5CT Installation Manual

Installation and Service Instructions
C
O
M
P
A
N
Y
R
E
G
I
S
T
E
R
E
D
MADE in the USA
Model ES5M
ES5 Series - Designed to operate without distilled water, Self Contained or Direct Water Hookup, Stainless steel construction
Specifi cations:
120 volts 60HZ AC 1500 watts, max 12.5 amp
ES5 1800 series - 1800 watts, max 15 amps
Manual pump (push button) or timer operation
Closed generator
Half Pan size
Removable water drawer (self contained models)
Spring loaded adjustable hinge with 60° or 90° opening
Food Grid
ES5 1800 series - 1800 watts, max 15 amps
ES5 1800 series - 20% faster temperature recovery time
Quick connect fi ttings (direct hookup models)
This manual contains suffi cient information for installation of the EmberGlo Steamer in normal locations.
ES5 Series
Top Open / Half Pan Counter Top Steamer
ES5 Series - 1500W
ES5CTS: Timer Operation with Water Pan ES5M: Manual Operation with Water Pan ES5MT Manual Operation with Water Pan
and Specially Perforated Tortilla Food Pan
ES5PBS: Push Button Operation with Water Pan ES5PCS: Fixed Timer Operation with Water Pan
ES5PB: Push Button Operation with Direct Water Connect ES5CT: Timer Operation with Direct Water Connect ES5PC: Fixed Timer Operation with Direct Water Connect
ES5 1800 Series - 1800W
ES5M18: Manual Operation with Water Pan ES5CTS18: Timer Operation with Water Pan ES5PBS18: Push Button Operation with Water Pan
ES5CT18: Timer Operation with Direct Water Connect ES5PB18: Push Button Operation with Direct Water Connect
As of June 2013 the following steamers are no longer being manufactured - they are replaced with CT series steamers
ES5TS - now ES5CTS ES5T - now ES5CT ES5PTS - now Obsolete
In the United States, installation must conform with local codes.
CAUTION: Cooking equipment should be used in an environment protected by an automatic fi re suppression
PURCHASER: Retain these instructions for future use. Post in a prominent location near the steamer.
system. Consult the National Fire Protection Association NFPA Code 96 or the latest edition of Standards for Installation of Equipment for Removal of Smoke and Grease-Laden Vapors
Warranty
From Commercial Cooking Equipment.
See the back of this manual for warranty.
WARNING: Improper installation, adjustment,
This warranty does not apply to damages resulting from accident, misuse, abuse or alteration.
alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before
No equipment may be returned without written authorization
installing or servicing this equipment.
from EmberGlo (or Midco). Returned goods must be shipped prepaid to the factory.
AVOID ERROR IN PARTS SELECTION. When ordering use complete EMBERGLO Part Number and Description. Furnish
Warranty card must be fi lled in and returned to EmberGlo (or Midco) to validate warranty.
Model Number, Bill of Material Number and Serial Number (if available) from the specifi cation plate found on the product. IMPORTANT: Availability of parts as well as specifi cations are subject to change without notice. Please consult factory for item availability.
SAFETY INFORMATION TERMS: The following terms are used to identify hazards, safety precaution of special notations and have standard meanings throughout this manual. They are printed in all capital letters using a bold type face as shown below, and preceded by the exclamation mark symbol. When you see the safety alert symbol and one of the safety information terms as shown below, be aware of the hazard potential.
EmberGlo
A Div of Midco® International Inc.
4140 West Victoria Street Chicago, Illinois 60646 toll free 866.705.0514 tel 773.604.8700 fax 866.580.8700 web www.emberglo.com e-mail sales@emberglo.com
DANGER: Identifi es the most serious hazards which will result in severe personal injury or death. WARNING: Signifi es a hazard that could result in personal injury or death. CAUTION: Identifi es unsafe practices which would result in minor personal injury or product and property damage.
As an ISO 9001:2008 certifi ed company, we proudly design, manufacture and assemble our products in Chicago, Illinois, USA.
Quality Designed for Proven Performance
U
®
L
8449 96
Printed in USA
517
ES5 Series - Installation
Installation
MADE in the USA
In the United States, wiring must conform to local codes, or in the absence of local codes, to the National Electrical code ANSI/NFPA No. 70-latest edition. In Canada, wiring must conform to local codes, or in the absence of local codes, to Canadian Electrical Code Part 1, CSA Standard
C22.1.
1. All ES5 Models: Locate on level surface and plug power cord into 120 volt, single phase 60Hz.
grounded outlet.
2. ES5M, ES5M18, ES5MT, ES5CTS, ES5CTS18, ES5PBS & ES5PCS: Fill water pan by pulling
water pan out to stop position and fi ll with cold water to top of baffl es, then close drawer.
3. ES5PB, ES5PB18, ES5CT, ES5CT18, & ES5PC: Connect water hose assembly to water
supply system. The supply end has 1/8″ female pipe fi tting and should be attached down stream to a shut-off valve. Steamer end of hose has a quick connect fi tting which snaps onto mating fi tting on steamer. This fi tting has an automatic shut-off valve that allows steamer to be disconnected without shutting off water supply. After connecting, turn on water and check for leaks.
4. EmberGlo Steamers do not require a separate hood for vapor produced during operation according to the Uniform Mechanical Codes per the International Conference of Building Offi cials Code. And there are no requirements in NSF Standard 4 (2006e) for steamers to
have ventilation.
5. Lid Angle Adjustment: To adjust the angle of the lid to 60° or 90°
1. With the lid closed, loosen and remove slotted screw. Set aside.
2. Remove lid stop by sliding it up and away from the steamer.
3. Adjust lid stop for desired position (60° or 90° open) and place on steamer.
4. Insert and tighten slotted screw. See Figure 1a, 1b and Figure 1c for orientation of lid stop. Factory default setting is 60°.
1
Figure 1c
1
90°
60°
Operation
2
2
Item # Part # Description
1 HW1-099 #8-32 X 5/16″ Slotted Pan Head Screw 18ss 2 1421-21 Lid Stop
Figure 1a
Back of ES Series Steamer
60° Opening Position
__________________________________________
General Instructions for Operation. For operation tips and recommendations see below. Before Using: (See Figure 2 for locations of buttons and switches)
1. Remove the protective plastic covering before using.
2. Steamers with self contained water drawers: If there is a water drawer open and fi ll reservoir
with water.
3. Steamers with direct hookup water supply: If the steamer is a direct hookup connect to a
water supply
4. Plug into 120V AC outlet.
5. Push power switch to the ON position (light on) and allow approximately 15-20 minutes to reach
operating temperature.
6. Test to make sure unit will generate steam (except the ES5PCS and ES5PC).
7. For ES5CT, ES5CT18, ES5CTS & ES5CTS18 steamers: Switch the Cycle/Manual switch to
the manual mode.
EmberGlo A Division of Midco International Inc
Back of ES Series Steamer
Lid Stop Reversed
90° Opening Position
2
Figure 1b
8449 96
ES5 Series - Operation
8. Press the round Steam button several times to remove the air from the system, you will notice it will start to steam. The Steamer is now ready to use.
General Operating Instructions: (See Figure 2 for locations of buttons and switches on timer models)
1. Open lid, place food on grid and close lid.
2. ES5M, ES5M18 & ES5MT: Press handle until it stops - then release. See Heating and Cooking Guide - 8474-75S for suggested number of operations or “shots” (a shot is one press
of pump handle). ES5PB, ES5PB18, ES5PBS & ES5PBS18: Push round button momentarily for each operation. Do not hold button more than one second.
Note: After installation, operate several times until the water hose fi lls with water.
ES5CT, ES5CT18, ES5CTS & ES5CTS18: (see Timer/Manual Operating Instructions below)
Operate the same as ES5PB & ES5PB18 above, or follow directions on label on front of unit which will automatically deliver three shots per minute for time set. At end of cooking time, READY light will come ON and signal will sound. Turn toggle switch to OFF to silence signal. ES5PC & ES5PCS (Preset Timer Models): Operates by pressing the round button to start thecook cycle. At the end of the cook cycle the READY light will come ON and the signal will sound.
3. Open lid and remove food.
4. For effi ciency and safety purposes, keep lid closed when not in use. This keeps the food pan hot and reduces condensation in the steam chamber.
5. To shut off , push power switch to OFF position.
Timer Operating Instructions with ES5CT, ES5CT18, ES5CTS & ES5CTS18 timer steamers: (See Figure 2 for locations of buttons and switches)
1. ES5CTS & ES5CTS18: Fill the water reservoir at the beginning of each day. During use check the water reservoir periodically.
2. Turn unit on, the Ready indicator will light.
3. Allow the steamer warm up for about 10 minutes.
4. Move the Cycle/Manual switch to the cycle mode.
5. Lift the lid and place product on the rack, close lid.
6. Rotate the timer dial to the desired cooking time.
7. Press the round Steam button to start the cooking cycle (the ready light will go out). Move the buzzer toggle switch to on position. Note: The steamer will automatically generate steam about every 15/20 seconds.
8. After the cycle has been completed, the Ready indicator light will turn on and the buzzer will sound indicating the cycle is done. Use the buzzer switch to turn off the buzzer.
9. Open the lid, carefully remove the very hot product.
10. The steamer is now ready for another cycle.
Operation
Continued
Manual Operating Instructions with a ES5CT, ES5CT18, ES5CTS & ES5CTS18:
1. Move the “Cycle/Manual” switch to the “Manual” mode.
2. Depress Round Steam push button approximately 1 second. Note: Excessive pressing of the steam button will fl ood the steam chamber.
1 65432
Item # Description
1. Steam Button - starts cycle timer or for manual steaming
2. Cycle/Manual Switch ­ Cycle is for position for timer usage Manual is for push button steaming
3. Cycle Timer - used to adjust cycle time
4. Signal Switch - turns on/off ‘Cycle Done’ buzzer
5. Ready Light - lights at the end of cycle time
6. Power Switch - turn on before usage for approximately 10 minutes to warm steamer
Figure 2
ES5CT, ES5CT18, ES5CTS & ES5CTS18 Steamers - Front Panel
8449 96
EmberGlo A Division of Midco International Inc
3
L1 NLGND
BLK
BLK
WHT
THERMOSTAT
OPEN @ 350°F
THERMAL
FUSE
HEATING
ELEMENT
1500 Watts
(OPT - 1800 Watts)
120V / 60Hz
WHT
GRN
BLK
BLK
WHT
BLK
PILOT
ON / OFF
R
WIRING DIAGRAM
HEATING
ELEMENT
BLK
HEATING
ELEMENT
THERMAL
FUSE
BLK
BLK
GRN
THERMOSTAT
WHT
WHT
LINE CORD
ON / OFF
PILOT
BLK
BLK
SCHEMATIC
ES5M, ES5M18 & ES5MT
FRONT PANEL CHASSIS
L1 NLGND
BLK
BLK
WHT
THERMOSTAT
OPEN @ 350°F
THERMAL
FUSE
HEATING
ELEMENT
1500 Watts
(OPT - 1800 Watts)
120V / 60Hz
WHT
GRN
BLK
BLK
WHT
BLK
PILOT
ON / OFF
R
PUSH
BUTTON
NC NO
COM
SOLENOID
VALVE
S
BLK
WHT
BLK
FRONT PANEL CHASSIS
SOLENOID
VALVE
THERMOSTAT
THERMAL
FUSE
HEATING ELEMENT
PUSH
BUTTON
PILOT
ON / OFF
HEATING
ELEMENT
LINE CORD
ES5PB & ES5PB18
WIRING DIAGRAMSCHEMATIC
FRONT PANEL CHASSIS
PUMP
THERMOSTAT
THERMAL
FUSE
HEATING ELEMENT
PUSH
BUTTON
PILOT
ON / OFF
HEATING
ELEMENT
LINE CORD
ES5PBS & ES5PBS18
WIRING DIAGRAM
L1 NLGND
BLK
BLK
WHT
THERMOSTAT
OPEN @ 350°F
THERMAL
FUSE
HEATING
ELEMENT
1500 Watts
(OPT - 1800 Watts)
120V / 60Hz
WHT
GRN
BLK
BLK
WHT
BLK
PILOT
ON / OFF
R
PUSH
BUTTON
NC NO
COM
PUMP
P
BLK
WHT
BLK
SCHEMATIC
ES5 Series - Schematic & Wiring Diagrams
4
Wiring Diagrams for ES5 Series Steamers - ES5M, ES5M18, ES5MT, ES5PB, ES5PB18, ES5PBS & ES5PBS18
Note: ES5 1800 Series Steamers have an 1800 watt heating element
EmberGlo A Division of Midco International Inc
Figure 3A
8449 96
Loading...
+ 8 hidden pages