EmberGlo ES10 User Manual

Installation Service
Manual
EmberGlo Model ES10
EmberGlo
A Division of Midco International Inc.
4140 West Victoria Street Chicago, Illinois 60646 tel 866.705.0515 fax 866.580.8700 web www.emberglo.com
Quality Designed for Proven Performance
210
8470 77
Printed USA
SAFETY INFORMATION TERMS: The following terms are used to identify hazards, safety precautions or
special notations and have standard meanings throughout this manual. When you see the safety alert symbol and one of the safety information terms, as shown below, be aware of the hazard potential.
DANGER: Identifies the most serious hazards which will result in sever personal injury or death. WARNING: Signifies hazards that could result in personal injury or death. CAUTION: Identifies unsafe practices which would result in minor personal injury or product and
property damage.
Full Pan Size Food Steamers
Automatic, Programable Timer Operation
Designed to Operate Without Distilled Water
ES10PB: Manual Push Button ES10TE: Automatic, Programmable Timer
Operation-External Cycle Timer
Midco International Inc Warranty Policy
Exclusions Terms, Customer Requirements and Instructions
Warranty
Only Authorized Service Providers are authorized to provide Warranty service on all EmberGlo, a Division of Micdo International Inc., food equipment as described under and Midco
®
International Warranty Policy. A list of providers can be found on
our web site: www.emberglo.com
Provisions:
In lieu of an implied warranty, all repairs and replacement parts furnished under our Warranty shall be f.o.b. point of distribution, but the owner must pay the necessary freight, delivery and labor costs involved when required. Any Federal, State or Local taxes are also extra. This Warranty is effective for a period of 1 (one) Year from the date of original installation. EmberGlo
®
Electric Food Preparation Equipment manufactured by Midco International, sold under the EmberGlo trademark, are guaranteed to be free from defect in material and workmanship under normal use and service for a period of 1 (one) year after the date of original installation. Midco's obligation under this Warranty Policy shall be limited to repairing or replacing, at our option, any part of said equipment which Midco examination shall disclose to its satisfaction to be thus defective.
Exclusions:
This Warranty Policy does not apply to damages resulting from accident, misuse, abuse or alteration, nor does it apply to limed steam generators, nor does it apply to any consequential damages. Most geographical areas require the use of distilled or demineralized water. Tap water is permissible only
with ES Series Steamers. Midco's obligation will be the replacement of the product or parts removed.
Terms:
Under the terms of this Warranty Policy, models considered portable (devices with cords and plug caps such as EmberGlo Steamers) must be taken or returned to the nearest service provider, transportation prepaid, returned transportation collect. Non-portable units with permanent wiring will be serviced on the
customer's premises. Under these terms, Midco agrees, within the terms of this Warranty period, to make all repairs at no charge by the authorized service provider. Labor and mileage charges submitted by any other provider not authorized will be the responsibility of the customer.
If a part is defective due to workmanship or materials and is removed from the product within the applicable warranty period and returned to Midco in accordance with the following procedure described, Midco will, at its option, either repair or replace the part. Call the factory for Instructions on returned goods.
No equipment may be returned without written authorization from MIDCO. Returned goods must be shipped prepaid to the factory.
__________________________________
No Hood Installation Required: According to the Uniform Mechanical
Codes per the International Conference of Building Officials Code EmberGlo Steamers do not require a separate hood for vapor produced during operation.
NOTE: EmberGlo ES10 Series Steamers use a cast aluminum steam generator with two cast in electric heating elements. For best steaming, the generator casting should contain some mineral deposits. During final inspection each generator casting is pre-seasoned with a solution of baking soda and water. The water marks and mineral deposits seen on a new generator casting when the perforated food pan is removed is your assurance that the unit has passed final inspection test and will readily produce steam.
Specifications:
- 240 volts 60HZ AC 3200 watts 13.3 amp or 208V 60HZ AC 2400 watts 11.6 amps
- Automatic timer operation (timer models only)
- Single shot operation
- End of cycle buzzer (10 seconds)
Installation
Operation
ES10 Steamers feature a 4" deep full size steam table pan. The steamer lid is equipped with two counter-balanced spring hinges and offers a convenient choice of four locations for installing the lid handle at the side or front of either front corner. Models Available for either manual or fully automatic steaming.
____________________________________
Standard ES10 Steamers are designed for use with 208 VAC to 240 VAC, 4 (3 pole with ground) wire, single phase, 60 Hz, electrical service. (See Figure 1). The generator casting contains two heating elements, each rated for 1600 Watts. 13.3 amps, 120 Volts, 60 Hz. Models are available for use on 50 Hz. (Non USA, Export only) electrical service. Call your distributor for more information. Standard units are furnished with a six foot, four conductor (2 Hot/1 Neutral/1 Ground) cord. This cord is equipped with a male twist-lock plug and matching loose female receptacle for convenient field installation.
____________________________________
Electrical. Female twist-lock receptacle, supplied loose with the steamer, should be installed by a qualified electrician. Refer to wiring diagrams. Figure 1.
NOTE: Female receptacle must be wired to assure that voltage to the individual heating elements does not exceed 150 volts. (Circuits R-W and BK-W on Fig 1 and 2.) G terminal is wired to Ground.W terminal is wired to neutral. Protect circuit with a 15 amp double pole circuit breaker.
In the United States, Wiring to the Female receptacle must conform to local codes, or in the absence of local codes, to the National Electrical Code ANSI/NFPA No. 70-1990, or latest edition. In Canada, Wiring to the Female receptacle must conform to local codes, or in the absence of local codes, to Canadian Electrical Code Part 1, CSA Standard C22.1. When choosing a location for the steamer, be sure that there is adequate space over the unit to lift lid completely. Water. Connect water hose assembly to water supply system. The supply end has a 1/8" female pipe fitting and should be attached downstream of a shut-off valve. Steamer end of hose has a quick connect fitting which snaps onto mating fitting on steamer. This hose fitting has an automatic shut-off valve that allows steamer to be disconnected without shutting off water supply. After connecting, turn on water and check for leaks.
No Hood Installation Required: According to the Uniform Mechanical Codes per the International Conference of Building Officials Code, EmberGlo Steamers do not require a separate hood for vapor produced during operation.
____________________________________
1. Push power switch to ON position (switch lights up). Allow approximately 15 minutes for steamer to reach operating temperature.
2. MODEL ES10PB: Push STEAM button momentarily for each shot of steam desired. Water is sprayed into the steam generator for as long as the button is depressed. If the STEAM button is depressed too long or too often, flooding of the steam generator will result. A one second shot of water every 20 seconds is a good rule of thumb to avoid flooding.
3. MODEL ES10: A.) For a single-shot steaming as with the ES10PB (above), flip the CYCLE/MANUAL switch
to the MANUAL side. Push the STEAM button for each shot of steam desired.
B.) For unattended steaming for up to 20 minutes, set the CYCLE/MANUAL switch to
CYCLE. Depress the STEAM button to activate a steaming cycle. Steaming will proceed according to the timer settings.
ES10 Series Installation and Service
2
Specifications
HEIGHT (lid closed) HEIGHT (lid open 90 degrees) with lid handle mounted on
front corner of lid, projecting forward.
HEIGHT (lid open 90 degrees) with lid handle mounted on
side corner of lid, projecting to the side.
WIDTH WIDTH with lid handle projecting to left or right side DEPTH
24.77
73.66
58.42
57.15
72.39
55.88
Dimensions
9 3/4"
29"
23"
22 1/2" 28 1/2"
22"
Inches Centimeters
Electrical
Maintenance
Daily
Installation
Continued
Timers are configured as follows:
CYCLE TIME: Sets the total length of product cooking time, during which steam is automatically supplied at adjustable intervals. At the end of the set time, steaming stops and the buzzer sounds. Adjustable from 0.2 to 20 minutes. STEAM SHOT “ON” TIME: Sets the amount of time that water is supplied to the steam generator to create steam. Adjustable from 0.1 to 0.5 seconds. STEAM SHOT “OFF” TIME: Sets the amount of the time between steam shots when no steam is supplied. Adjustable from 6 to 18 seconds. BUZZER DURATION: Sets the length of time that the buzzer will sound after automatic steaming is completed. Adjustable from 0.1 to 10 seconds. DELAY FROM LAST SHOT TO BUZZER: Sets the length of time between the last shot of steam and the sounding of the buzzer. This dwell time allows absorption of steam into
the food. Adjustable from 0.1 to 30 seconds. The adjustment features have been located within the steamer control box and made accessible only with a screwdriver in order to discourage tampering or readjustments by unauthorized personnel.
DANGER: Use extreme caution when adjusting timers. Bare wire terminals and/or bare wires are exposed. Unplug male twist-lock plug or use extreme caution if steamer is plugged in when making timer adjustments. Use an insulated or fiberglass screw driver. IMPORTANT: KEEP LID CLOSED WHEN NOT IN USE. This keeps the food pan hot and
reduces condensation in the steam chamber. When steamer is first installed, or when reconnecting water hose, operate STEAM button several times to purge air from lines.
____________________________________
Food Pan and Grid on all models should be removed and washed with a detergent or run through a dishwasher.
WARNING: Under no circumstances should the entire Steamer be run through a dishwasher. If any of the switches or timers in electric control compartment get wet they can malfunction. Never try to use a device that has been wet—replace it.
All exposed stainless steel surfaces should be wiped with a damp cloth or cleaned with a chlorine free stainless steel cleaner. Rust spots can develop on stainless steel surfaces that are not cleaned daily.
____________________________________
3
Figure 1: Wiring Diagram
ES10 Series Installation and Service
Loading...