Operating voltage
+9V...32V
Operating temperature
-30...+80C
Current consumption on stand-by
< 30mA (12V)
Operating range of the heat sensor
-55...+125C
PARTS OF INSTALLATION
REMUC-2-AC controller External antenna Cables needed for installation GPS/GLONASS receiver (only Remuc PLUS)
Illuminated usage button
ELECTRICAL FEATURES
INSTALLER GUIDE
IMPORTANT INFORMATION
WARNING! Familiarize yourself with usage, service and safety instructions supplied with
the device that is controlled using REMUC.
CONTROLLER MUST BE INSTALLED SO THAT THE INSTALLATION NEVER
EXCEEDS GIVEN VOLTAGE AND CURRENT INPUT LIMITS. CURRENT INPUT MUST BE GUARDED WITH A 5A FUSE
PIN code for the SIM card must be one of the following: ”1234”, ”0000” or the PIN code
query must be disabled completely
If any other SIM card is used than the one included in the package, SIM card functionality
must be verified with a mobile phone before installation.
CONNECTING REMUC USAGE BUTTON
Installer should proceed with caution when assembling usage button connector. Wire contact going in the plug must be in correct orientation and of correct color, otherwise breakage may occur.
v1.2 © 2014 Embelin Ltd. , all rights reserved
CONNECTOR SCHEMATICS
RC2A
Cable with full wiring
RC2AE
Basic installation cable (Eberspächer)
RC2AL
Basic installation cable (Webasto)
Cable
RC2A RC2AE RC2AL
1
BLACK
Ground
x x
2
ORANGE
WBC x 3
NC
4
NC 5
GRAY
Button
x x x
6
GRAY
x x x
7
GRAY
Input 1
+0V...+24V (>1V = active)
8
VIOLET
Input 2
+0V...+24V (>1V = active)
9
RED
Vin
+12V…+24V (5A fuse needed)
10
YELLOW
Output1 (+) (heater control)
Output 0,5A (no fuse) Vin voltage (PIN 9)
11
WHITE
Output2 (+) (Fan control)
Output 0,5A (no fuse) Vin voltage (PIN 9)
12
GREEN
Button
x x x
13
BROWN
Button
x x x
14
BROWN
Temp sensor
x x x
15
NC
16
BLACK
Ground
x
Three different installation cables are available:
PIN
COLOUR FUNCTION
NO
x x x x x x x
INFORMATION
RESETTING REMUC WITH USAGE BUTTON
RESET / RESTART
1. Press and hold usage button at least 10 seconds. Release button.
2. Status light on usage button blinks for 10 seconds. After this controller is reset.
3. REMUC is ready for use when blinking stops.
FACTORY RESET
1. Press and hold usage button for at least 10 seconds. R el e ase but t o n.
2. Status light on usage button blinks for 10 seconds. During this time press button
shortly 3 times.
3. Controller will be reset to factory settings.
4. REMUC is ready for use when blinking stops.
STATUS LIGHTS AND CONNECTIONS
Controller status LED (orange)
o Blinks: Controller is restarting o Lit: Controller is powered and connected to a network
GSM modem status LED (red)
o Blinks in 1 s intervals: Searching network or SIM card is not inserted or it’s locked. o Blinks in 3s intervals: Connected to a network
If controller status LED does not switch to continuously lit mode after 5 minutes from restart,
check SIM card PIN code. PIN code MUST be “1234”, “0000” or disabled. W ipe the SIM card contacts clean.