emaux SP500, SP450, SP650, SP700 User Manual

1-4
4-4
Models: SP450 / SP500 / SP650 / SP700
EMFI16 021904
Pipe sealant for plastic adapters are required to install and service the filter.
1) The filter should be placed on a level concrete slab, very firm ground, or equivalent. Position the filter so that the piping connections, control valve are convenient and accessible for operation and service.
2) Loading the sand media. Filter sand media is loaded through the top opening of the filter.
and glues.(see the fig on page4).
b) Loosen the Ring lock Nut by 2 handles and remove the valve. c) We recommend filling tank approximately 1/3 way with water to provide a cushion effect when the filter
sand is poured in. This helps protect the under-drain laterals from excessive shock.
d) Carefully pour in correct amount and grade of filter sand. Sand surface should be leveled and should
come to about the middle of the filter tank.
INSTALLATION
FUNCTION
The filter uses s pecial filter san d to remove dirt p articles from poo l water. The filter sand is loaded i nto the filter tank and functions as the permanent dirt removing media.When the control valve is in the FILTER position, the pool water which contains suspended dirt particles, is p umped thr ough you r piping system and is automati cally directed by the patented filter control valve to the top of the fi lter tank.As t he pool water is pumped th rough the filter, d irt particles are trapped by the sand bed, and filtered out. T he cleaned Po ol water is returned from the bottom of the filter tan k,through t he control valve and bac k to the pool through the pipin g system. This entire sequence i s continuou s and automatic and provid es for total recirculation of pool water through your filter and piping System.
After a period of time the accumulated dirt in the filter causes a resistance to flow, and the flow diminishes. Thismeans it is time to clean your filter. With the control valve in the BACKWASH position, the water flow is automatically reversed through the filter so that it is directed to the bottom of the tank, up through the sand, flushingthe previously trapped dirt and debris out the waste line. Once the filter is back-washed of dirt, set control valve toRINSE position and run pump for about 1/2 to 1 minute, and then to filter, to resume normal filtering.
NOTE: Turn pump off before changing valve position.
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED . PRESSURIZED AIR CAN CAUSE THE LID OR VALVE TO BE BLOWN OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TURN PUMP OFF BEFORE CHANGING VALVE POSITION. TO PREVENT DAMAGE TO THE PUMP AND FOR PROPER OPERATION OF THE SYSTEM, CLEAN PUMP STRAINER AND SKIMMER BASKETS REGULARLY. DO NOT UNSCREW SCREWS OF FLANGE CLAMP WHILE PUMP IS RUNNING.
SYSTEM (e.g., CLAMP,
WARNING
FUNCTIONS OF VALVE POSITIONS
GENERAL
1) Pipe tap boss provided for optional influent pressure gauge.
2) SERVICING VALVE( Stop pump,close gate valve in suction&discharge before proceeding): a) Set handle in filter position. b) Remove cover screws. c) Lift cover and key assembly out.
TO ASSEMBLE:
1) Place valve key so that wedge opening is at TOP port (handle in Filter psn.). Flat edge of cover screw lug should align with flat edge of body screw lug.
2) Position cover O'Ring.
3) Secure assembly to body with cover screws. Tighten cover screws evenly and alternately. Do not over­tighten.
WASTE
FILTER
BACKWASH
RINSE
WASTE
RECIRCULATE
CLOSED
WASTE WASTE
WASTE WASTE WASTE
IN FLOW
OUT FLOW
IN FLOW
OUT FLOW
IN FLOW
OUT FLOW
IN FLOW
OUT FLOW
IN FLOW
OUT FLOW
IN FLOW
OUT FLOW
By-passes filter for circulating water to pool
Used after backwash to flush dirt from valve
Cleaning Filter by reversing the flow
By-passes filter, used for vacuuming to waste or lowering water level
CLOSED Shuts off all flow to filter or pool
RECIRCULATE
WASTE
RINSE
BACKWASH
FILTER
Valve Position
Normal Filtration and Vacuuming
Function
NOTE: During initial clean-up of the pool water it may be necessary to backwash frequently due to the unusually heavy initial dirt load in the water.
2-4
MAIN DIMENSION
REPLACEMENT PARTS OF FILTER
3-4
3) Replace filter coping (with O'ring in place). a) Carefully screw pressure gauge (with O'ring in place) into tapped hole in the filter coping. Do not over-
tighten.
b) Ensure air relief valve (with O'ring in place) is tight fit to filter coping and turn it easily.
4) Connect pump to control valve opening marked PUMP.
5) Make return to pool pipe connection to control valve opening marked RETURN and complete other necessary plumbing connections, suction lines to pump, waste, etc.
6) Make electrical connections to pump per pump instructions.
7) To prevent water leakage, be sure all pipe connections are tight.
B
A
455
535
635
710
Model
A
High
mm
B
Diameter
mm
730
770
850
960
SP450
SP500
SP650
SP700
inch
Valve
Sand
kg
1.5 "
1.5 "
45
85
1.5 "
1.5 "
145
210
INSTALL/START-UP OF FILTER
1) Be sure correct amount of filter media sand is in tank and that all connections have been made and are
secure.
2) Depress control valve handle and rotate to BACKWASH position. (To prevent damage to control valve
seal, always depress handle before turning.)
3) Prime and start pump according to pump instructions (be sure all suction and return lines are open),
allowing the filter tank to fill with water. Once water is flowing out of the waste line, run the pump for at least 1 minute. The initial back-washing of the filter is recommended to remove any impurities or fine sand particles in the sand media.
4) Turn pump off and set valve to RINSE position. Start pump and operate until water in sight glass is clear,
about 1/2 to 1 minute.Turn pump off and set valve to FILTER position and restart pump.The filter is now operating in the normal filter mode, filtering dirt particles from the pool water.
5) Adjust pool suction and return valves to achieve desired flow. Check system and filter for water leaks and
tighten connections, bolts, nuts, as required.
6) Note the initial pressure gauge reading when the filter is clean. (It will vary from pool to pool depending
upon the pump and general piping system.) As the filter removes dirt and impurities from the pool water, the accumulation in the filter will cause the pressure to rise and flow to diminish. When the pressure gauge reading is 1.5 bar, higher than the initial "clean" pressure you noted, it is time to backwash the filter (see BACKWASH under filter and control valve functions).
DIMENSION TABLE
Key N o.
Par t No.
Des cript ion
Qty
1
890 10701
Air R eleas e Valve w ith O-r ing
1
2
060 21009
Pla stic Pr essur e Gauge W ith O-R ing
1
2
011 11048
Con necto r for Pre ssure G auge/ Stopp er
1
3
012 01022
Lid ( Trans paren t)
1
4
030 21035
M6 Nu t25
030 11095
Scr ew26
012 71010
Cla mp Lock
2
7
020 11134
O-R ing for F ilter N eck
1
8
890 10712
SP4 50 Filt er tank
1
8
890 10713
SP5 00 Filt er tank
1
8
890 10714
SP6 50 Filt er tank
1
8
890 10715
SP7 00 Filt er tank
1
9
890 10708
S/S P450 th e inner t ank sys tem
1
9
890 10709
S/S P500 th e inner t ank sys tem
1
9
890 10710
S/S P650 th e inner t ank sys tem
1
9
890 10711
S/S P700 th e inner t ank sys tem
1
10
011 11046
1.5 "Tank S ystem S uppor t
1
11
011 72007
Lat erals ( 115mm )
8
11
011 72008
Lat erals ( 126mm )
8
12
020 11003
O-R ing for i nlet & ou tlet
2
13
882 80811 B
6 Way 1 .5" Val ve with P iping K it, 1.5 " union s et x 3 and pr essur e gauge ( Black )
1
14
890 11601
Wat er Drai n Set
1
15
011 11059
16- 21inc h Filte r Base
1
15
011 11062
21- 28inc h Filte r Base
1
Loading...