Elvox 40510 Instruction Manual

Instruction manual
40510
7” Due Fili Plus porter switchboard
2
7” Due Fili Plus porter switchboard
GENERAL INFORMATION
Device 40510 is a switchboard for the DueFili Plus video door entry system, equipped with a 7-inch colour screen. It can be used in hands-free mode or with a handset.
The instruction manual can be downloaded from www.vimar.com
Installation rules
Installation should be carried out in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are installed.
Regulatory Compliance
EMC directive Standards EN 60065, EN 61000-6-1 and EN 61000-6-3.
INFORMATION FOR USERS UNDER DIRECTIVE 2002/96 (WEEE)
In order to avoid damage to the environment and human health as well as any administrative sanctions, any appli-
ance marked with this symbol must be disposed of separately from municipal waste, that is it must be reconsigned to the dealer upon purchase of a new one. Appliances marked with the crossed out wheelie bin symbol must be collected in accordance with the instructions issued by the local authorities responsible for waste disposal. For more information call the free-phone number 800-862307.
This product was developed using FreeRTOSTM software - http://www.freertos.org/
3
VIMAR group
7” Due Fili Plus porter switchboard
Main functions
The switchboard offers the following functions:
1. making and receiving audio calls with the indoor units;
2. receiving audio/video calls from the speech units;
3. implementing automatic self-starts from the speech units;
4. forwarding speech unit calls to indoor units;
5. calling another switchboard;
6. managing warnings from indoor units;
7. managing speech unit locks, stair lights and system relays;
8. activating CCTV cameras for monitoring purposes;
9. logging calls, warnings and activations.
Advanced functions
1. management of Competence Areas
2. management of operation time bands (Day/Night)
3. interception / non-interception of calls (Indoor/Outdoor mode)
The following languages are supported:
1. Italian
2. English
3. French
4. German
5. Spanish
6. Greek
7. Portuguese
Technical characteristics
Technical data:
• Supply voltage: 28VDC nominal Power supply via power supply unit 6923 (not supplied)
• Maximum absorption: 300 mA
• Absorption in standby: 86 mA
• 7-inch colour display, 800x480 pixel resolution, 16:9 format
• Ambient class: Class A1 (indoor use)
• Protection degree IP30
• Operating temperature: -5°C to +40°C (indoor use)
• Operating ambient humidity 10 - 80% (non-condensing)
• Electronic chimes with different tunes (10 melodies).
• Dimensions: 242x213x221 mm (WxHxD with support open)
• DIP switch for line impedance termination.
4
7” Due Fili Plus porter switchboard
Front view
Keyboard
Handset
Screen
Rear and side view
Mini USB connector for connection to a PC
RJ45 socket for connection
to the Due Fili Plus system
via stud
Dip switch for video termination
5
VIMAR group
7” Due Fili Plus porter switchboard
Keyboard
Key Description
Menu / Select Exit / Cancel Up
Down
Alphanumeric keys
Hands-free
End Conversation
Internal / External Day / Night Self-start Keyboard lock Hold Input / Transfer F1 (programmable)
F2 (programmable) Contacts List
List of alert notifications
Events list
Lock
6
7” Due Fili Plus porter switchboard
Indicators
LED Status Description
Steady light Power - Switchboard on
Steady light Switchboard connected to a PC via USB
Flashing light Unanswered call indication and/or alert notification
7
VIMAR group
7” Due Fili Plus porter switchboard
External connections
Switchboard 40510 is connected via the “Interconnecting stud” and the corresponding RJ45 Cat. 5E connection cable supplied.
+U +I
PRI
-
6923
BU OG BK RD
WHBNYEGN
**
Important: Strictly observe the connections on the con­necting stud. Inverted wiring connections may lead to the switchboard being damaged.
**
Due Fili Bus
Important: The maximum connection dis­tance between power supply unit 6923 and the interconnecting stud is 10 m.
Interconnecting
stud
Length: 3 m
Mains
Power Supply unit
8
7” Due Fili Plus porter switchboard
+U +I
PRI
-
6923
BU OG BK RD
WHBNYEGN
Note: We recommend connecting the cables with a fork Faston of a size suited to the stud screws, and inserting
it between the head of the screw and the washer, arranging the cables so as to avoid contact between adjacent Fastons.
Connection correspondence table: interconnecting stud - Due Fili system
Connection box terminals Connection box wire colour Due Fili audio / video door entry system
BU 1
Blue
1 (Due Fili Bus)
OG 2
Orange
2 (Due Fili Bus)
BK 3
Black
from power supply unit 6923 terminal -
RD 4
Red
from power supply unit 6923 terminal +I
GN 5
Green
-
YE 6
Yellow
-
BN 7
Brown
-
WH 8
White
-
Access hole for Due Fili Bus and power supply cables
to switchboard
Video Termination
Select DIP switch to terminate the video signal
A) if the BUS cable enters terminals BU (1), OG (2) of the switchboard interconnecting stud and continues to another indoor
unit.
B) when a BUS cable with typical impedance of 100 Ohm (Elvox cable 732I or 732H) enters terminals BU (1), OG (2) of the
interconnecting stud and the riser stops in the switchboard.
C) when a BUS cable with typical impedance of 50 Ohm (Cat. 5 or Cat. 6 twisted pair cable) enters terminals BU (1), OG (2) of
the interconnecting stud and the riser stops in the switchboard.
9
VIMAR group
7” Due Fili Plus porter switchboard
GRAPHICAL INTERFACE
First line
The following icons may appear on the first line of the screen, starting from the left:
The ringtone is disabled. The switchboard nevertheless accepts calls and it is possible to answer.
A notification that a door is open has been received.
The microphone is disabled.
The keyboard is locked.
The conversation is taking place in hands-free mode.
The conversation is taking place via the handset.
Internal mode
External mode
Internal mode with call filter enabled
External mode with call filter enabled
Automatic Internal/External enabled
Automatic Internal/External disabled
Last line
The date and time appear on the last line, in the format chosen during configuration.
10
7” Due Fili Plus porter switchboard
Standby
Stand-by screen
The switchboard enters standby mode after a specified time. In this mode, screen brightness is reduced and electricity consumption limited.
If a function button is pressed when the switchboard is in standby, that function is implemented immediately once the switchboard has awoken. In standby, the key
wakes up the switchboard without implementing any other functions.
Keyboard
The keys carry out their functions when released. If pressed for at least 0.5 seconds, the following keys perform another function:
KEY STANDBY TALKING
Ringtone mute Microphone mute
(Not applicable) Change parameter in adjustment
Self-start list
Activation list
To serve similar events “indirectly” (Not applicable)
To serve similar alerts “indirectly” (Not applicable)
With events / alert filter enabled, enter the
filter ID.
(Not applicable)
When viewing the contacts list, exit directly
to standby if the filter is enabled
(Not applicable)
When viewing events / alert, to delete them
after entering the installer PIN
(Not applicable)
During clock adjustment, requests the date/
time from the device configured as Master
Clock
(Not applicable)
11
VIMAR group
7” Due Fili Plus porter switchboard
Keyboard lock
The key locks the keyboard. To unlock it, press the key again, enter the unlock PIN (default 0000) and press
the key
. When locked, calls can still be answered by pressing the key or lifting the handset. At the end of
the call the switchboard reverts to locked mode.
12
7” Due Fili Plus porter switchboard
Basic settings
In standby, the key calls up the settings menu, which can be navigated in circular manner using the and keys. To configure a setting, navigate the list using the
and keys until you have selected the desired option
(highlighted in orange), then press
. The list of available options and possible settings will follow:
Basic settings menu
• Ringtone mute
Using the and keys, you can enable/disable the switchboard ringtone. When the ringtone is disabled,
the icon
will appear in the top right-hand corner of the screen. Press to confirm or press to cancel
without saving.
Default: ringtone enabled.
Ringtone enable
Ringtone disable
• Select call melody from speech unit
Use keys and to select one of the 10 available melodies (identified by letters A to J) to use as a ringtone
for calls from the speech unit. The switchboard plays back the selected ringtone. Press
to confirm or press
to cancel without saving.
Default: melody B.
13
VIMAR group
7” Due Fili Plus porter switchboard
Speech unit call ringtone
Ringtone selection
• Select landing call melody
Use keys and to select one of the 10 available melodies (identified by letters A to J) to use as a ringtone
for calls from the landing. The switchboard plays back the selected ringtone. Press
to confirm or press
to cancel without saving.
Default: melody C.
Landing call ringtone
• Select call melody from indoor unit or switchboard
Use keys and to select one of the 10 available melodies (identified by letters A to J) to use as a ringtone
for calls from an indoor unit or switchboard. The switchboard plays back the selected ringtone. Press
to
confirm or press
to cancel without saving.
Default: melody D.
Intercom call ringtone
14
7” Due Fili Plus porter switchboard
• Ringtone volume control
Use keys and to increase/decrease the ringtone volume, which is indicated by the horizontal bar. Press
to confirm or press to cancel without saving. NOTE: the set level is used for all ringtone types (calls from the speech unit, landing, indoor unit or switchboard). Default: level 5.
Ringtone volume selection
Ringtone volume control
• Date and time adjustment
The keys and can be used to select the field you wish to change, moving right and left respectively. Use
the number keys to change the value of the selected field. Press
to confirm and update the date and time, after checking its validity. If the date and time are not correct, the switchboard will emit an error tone and move the cursor to the first incorrect field.
Date and time adjustment selection
Date and time configuration
NOTE: In the event of a power cut, the device will be able to continue to update the date and time for 48 hours.
NOTE: If the relative function is enabled using SaveProg, the switchboard will automatically adjust the clock at the
start and end of Daylight Saving Time. At 02:00 on the last Sunday in March, it will set the time to 03:00, while at 03:00 on the last Sunday in October, the time will be set to 02:00. By default, this function is not enabled.
NOTE: A short press of the
key enables/disables the Master Clock function. When this function is enabled, a tick symbol √ appears alongside the time, and the device will act as the system reference for the date and time, so that all the switchboards will be synchronized automatically (without having to manually set the date and time on each device).
Press the
key for 0.5 seconds and the device will be immediately synchronized with the system's Master Clock
switchboard, if present.
15
VIMAR group
7” Due Fili Plus porter switchboard
Master Clock activation
• Key tone
Use the keys and to enable/disable the tone produced whenever a key is pressed (keystroke feedback).
Press
to confirm or press to cancel without saving.
Default: enabled.
Key tone
• Installer menu
After selecting the option and pressing
, the installer PIN will be requested. The menu then allows access to
the advanced settings:
Installer menu
Installer PIN input
16
7” Due Fili Plus porter switchboard
Advanced settings
The settings menu can be navigated in circular manner using the and keys. To configure a setting, navigate the list using the
and keys until you have selected the desired option (highlighted in orange), then press . The
list of available options and possible settings will follow:
Advanced settings menu
• Switchboard ID
Press to start the ID configuration procedure. In the next screen, enter the desired ID and then press
to confirm. Wait for the verification process to finish; a progress bar will be displayed on the screen. If the verification is completed successfully, the new switchboard ID will be displayed; if not, the device will retain the previous ID and signal the error.
Default: 1
For a vertical installation, the ID number must be within the range of 1 to 4. For a horizontal installation, the ID number
must be within the range of 129 to 144.
If the type of installation is changed (from vertical to horizontal or vice versa), the ID will no longer be valid (value
indicated as 0) and must be reconfigured.
Switchboard ID
ID setting
17
VIMAR group
7” Due Fili Plus porter switchboard
ID verification
Confirm ID
• Language
Use the keys and to select the desired language. Press to confirm or press to cancel
without saving.
Default: Italian.
Language
Language selection
• Date format
Use the keys and to select the desired date display format. Press to confirm or press to
cancel without saving.
Date format
18
7” Due Fili Plus porter switchboard
• Time format
Use the keys and to select the desired time display format. Press to confirm or press to
cancel without saving.
Time format
• Standby cut-in time
Use the keys and to select the period of inactivity after which the switchboard will switch to stand-by
mode. Press
to confirm or press to cancel without saving.
Default: 10 seconds.
Standby time
• Numbering plan
Use the keys and to select the numbering plan, choosing between: natural, 4-digit (available for vertical
installation only) and 8-digit. Press
to confirm or press to cancel without saving.
Default: natural.
For further details, refer to the paragraph "4- or 8-digit Numbering".
19
VIMAR group
7” Due Fili Plus porter switchboard
Numbering plan
Natural
4-digit
8-digit
• Horizontal or vertical installation
Use the keys and to select vertical or horizontal installation type. Press to confirm or press
to cancel without saving.
Default: vertical.
Whenever this parameter setting is changed, the switchboard ID will no longer be valid (status indicated by ID 0),
and will have to be reconfigured.
Furthermore, if the installation type is changed from vertical to horizontal and the current numbering plan is 4-digit,
this will automatically be changed to 8-digit, as the 4-digit plan is not compatible with a horizontal installation.
Horizontal/Vertical installation
20
7” Due Fili Plus porter switchboard
Vertical
Horizontal
• Reset of all parameters to default factory settings
Press to start the procedure to reset the switchboard configuration. The reset confirmation screen is displayed
(see below): press
to proceed or to cancel and maintain the current configuration.
The reset does not affect contacts lists and event lists, which will be retained in the device memory.
Reset default factory settings
Reset confirmation request
• Installer PIN
Press to start the procedure to change the installer PIN (required to access to the advanced settings menu).
In the next screen, enter four digits. Press
to confirm or press to cancel without saving.
Default: 1234.
Installer PIN
PIN setting
21
VIMAR group
7” Due Fili Plus porter switchboard
• Keyboard unlock PIN
Press the procedure to change the keyboard unlock PIN. In the next screen, enter four digits. Press to
confirm or press
to cancel without saving.
Default: 0000.
Keyboard unlock PIN
PIN setting
• Events list procedures
This option is restricted to the technical assistance service. Do not select it unless this is expressly indicated by the
technical assistance service.
• System information
This option is restricted to the technical assistance service. Do not select it unless this is expressly indicated by the
technical assistance service.
22
7” Due Fili Plus porter switchboard
USING THE DEVICE
Call to indoor unit or switchboard
To call, carry out one of the following actions:
• Enter the number on the keyboard, then lift the handset or press
.
• Select the entry in the contacts list (see sub-section “Search contacts list” below), then lift the handset or press
.
Dialling
Conversation in progress
The call can be ended using the key
, or if the handset is lifted, you can also hang up.
Wait for the call to be answered. The conversation can then be ended as described above.
4- or 8-digit Numbering
In the Due Fili Plus system, and thus also in the switchboard, some devices are able to identify indoor units with different numbers to their ID, or natural numbering. This is referred to as remapping. For a vertical installation, remapping numbers can be chosen from 1 to 4 digits or from1 to 8 digits. For a horizontal installation, from 1 to 8 digits. Usually the numbering follows a logical pattern, such as a division into complex / apartment block / stairway / apartment, but there are no restrictions.
The remapping numbers are defined in the contacts list (only using SaveProg). The effective application of this function can be decided switchboard by switchboard using the specific configuration de-
scribed in the paragraph "Installer menu" at point 6. When remapping is active, in addition to being visible in the details of the users list, it will be used exclusively to identify an
indoor unit, for both calls received and calls made to the unit. It is not possible to make calls to an indoor unit for which remapping has not been defined. If one of these indoor units calls
23
VIMAR group
7” Due Fili Plus porter switchboard
the switchboard, it's ID will be displayed preceded by the symbol ‘-‘.
Incoming call (from speech unit, indoor unit or switchboard)
In the event of an incoming call, before answering you can:
• Mute the chime (for the current call only) by pressing the key
for 0.5 seconds.
• Reject the call by pressing the key
.
• While it is ringing, adjust the chime level using the
and keys.
• In the event of a video call, adjust the brightness and contrast. Press and hold key
for 0.5 seconds to
select the parameter you wish to adjust: chime level, brightness or contrast. Selection is cyclical. Then use keys
and to increase or decrease the level.
Information relating to the caller appears in the bottom right-hand corner:
• In the event of a call from the speech unit to the switchboard: the number (and any name included in the self-start contacts list) of the speech unit making the call.
• In the event of a call from the indoor unit to the switchboard: the number (and any name included in the user contacts list) of the indoor unit making the call.
Incoming call from speech unit to switchboard
Incoming call from indoor unit to switchboard
The
symbol indicates that it is a speech unit. The symbol indicates that it is an indoor unit.
Answering a call
To answer a call from a speech unit, indoor unit or switchboard:
• When the handset has been hung up, carry out one of the following actions:
o Lift the handset: the conversation will be enabled for the handset
o Press the key
: hands-free conversation will be enabled
• With the handset lifted, carry out one of the following actions:
o Replace and then lift the handset again: the conversation will be enabled for the handset
o Press the key
: hands-free conversation will be enabled
After answering, lift the handset to switch from hands-free to handset mode. Conversely, to switch from handset to hands-
free mode: press and hold the key
, hang up the handset and then release the key .
24
7” Due Fili Plus porter switchboard
Conversation with indoor unit in progress
Conversation with speech in unit progress
Adjustments during a conversation
During the conversation, it is possible to adjust:
• Loudspeaker level (differentiated for conversation with indoor unit and speech unit and for hands-free and handset conversation).
• Microphone level (differentiated for conversation with indoor unit and speech unit and for hands-free and handset conversation).
• Brightness (in the case of a video conversation)
• Contrast (in the case of a video conversation)
Once the conversation has started, the loudspeaker level can be adjusted using the keys
and . The level varies according to whether the conversation is with an indoor unit or a speech unit, and the relative adjustment applies only to the type of call in progress.
To adjust the other levels, press and hold key
for 0.5 seconds: the bar relating to one of the four parameters ap-
pears cyclically at the top of the screen, on the same line as the status icons. Press and hold key
for 0.5 seconds
until the parameter you wish to adjust is selected (loudspeaker, microphone, brightness, contrast), then use keys
and
to increase or decrease the level.
Press and hold key
for 0.5 seconds to mute the microphone. A specific icon appears in the status bar while this
status is applied. To re-enable the microphone, repeat the process.
End conversation
To end the conversation, carry out one of the following actions:
• Press key
• Hang up the handset (if the conversation took place via the handset)
Putting a call on hold and transferring a call
Press key to put the indoor or speech unit involved in the conversation on hold temporarily. The device previously involved in the conversation will emit a specific tone as notification of its on-hold status. While on hold, if the handset is hung
up, the call is not ended. Press key
again to resume the conversation.
A second call can be started while the first call is on hold: enter the number you wish to call, then press the
key
or lift the handset (hang up and lift again if it was already in use). Also, while a conversation is taking place, enter a number
and press the
key to automatically place the current conversation on hold and start a direct call to the newly entered
25
VIMAR group
7” Due Fili Plus porter switchboard
number. When the switchboard is in Internal mode and receives a call from a speech unit intended for an indoor unit, after entering
into a conversation with the speech unit, that call can be put on hold and a second call made to the requested indoor unit
by pressing key
, followed by . In the event of a call to a second indoor unit, after receiving an answer, the switchboard can place the two indoor units in a conversation with one another. Press key
to transfer the call.
The following sequence illustrates the main steps in the procedures for putting a call on hold, starting a second call and transferring a call.
1. Call from speech unit to indoor unit, intercepted by switchboard in indoor mode.
Speech unit 1 (pedestrian entrance) calls user Mario Rossi, indoor unit 1. As the switchboard in in Indoor mode, the call is received by the switchboard.
2. Conversation between switchboard and speech unit.
The switchboard operator responds by lifting the
handset or pressing
and enters into conversa-
tion with speech unit (pedestrian entrance).
3. Speech unit put on hold by switchboard.
The switchboard operator, after talking to the speech unit, puts it on hold by pressing
, in order to contact the requested user (hypothesis A) or another indoor unit (hypothesis B).
26
7” Due Fili Plus porter switchboard
(Call from switchboard to requested indoor unit):
4A. Indoor unit called by switchboard
The switchboard operator makes the call to the re­quested user (Mario Rossi) by pressing
and
then
.
5A. Conversation between indoor unit and
switchboard
The user Mario Rossi answers the call and enters into conversation with the switchboard operator.
6.A Transfer of conversation between indoor unit
and speech unit
The switchboard transfers the conversation to the speech unit by pressing
. The speech unit (pedestrian entrance) and the user of the indoor unit (Mario Rossi) start direct conversation and the switch­board operator quits the conversation.
(call from switchboard to another indoor unit):
4.B Call from switchboard to an indoor unit other
than that requested
Instead of contacting the requested indoor unit, the switchboard operator contacts a different indoor unit,
by dialling the ID and then pressing
: specifi­cally contacting the user Andolfo Zanardo at indoor unit 3.
27
VIMAR group
7” Due Fili Plus porter switchboard
6.A Transfer of conversation between indoor unit
and speech unit
After conversing with the user Andolfo Zanardo (in the same way as in point 5 A), the switchboard operator transfers the call to the speech unit by
pressing
. The speech unit (pedestrian entrance) and the user of the indoor unit 3 (Andolfo Zanardo) start direct conversation and the switchboard operator quits the conversation.
Input
After the switchboard has joined an indoor unit and speech unit (or another indoor unit) in conversation, if one of the two devices involved in the conversation is located in the same system segment/island as the switchboard, the conversation in progress indication remains on the screen of the latter.
In this situation, the switchboard can enter the conversation by means of key
. A specific tone, sounding over the conversation, alerts the users that the switchboard has joined. The switchboard can hear and be heard by all units but cannot force an end to the conversation. If the switchboard leaves the conversation, the other users continue. If one of the two other users ends the conversation, the switchboard will also be forced to leave the conversation.
The switchboard always joins with the audio levels of an indoor conversation.
Internal / External
Press to toggle between Indoor and Outdoor operating mode. This function is only available if the "Competence Areas" function is disabled (see paragraph below). The switchboard only changes mode if the bus status is not “busy”: otherwise it emits an audible and visual warning and
maintains the current operating mode. In Outdoor mode, the switchboard only receives from the speech unit the calls that are specifically addressed to it. In Indoor mode, the switchboard receives not only the above type of calls, but also all calls originating from any speech unit
connected to the same segment/island to which the switchboard is assigned.
Automatic Indoor / Outdoor mode
IT IS possible to configure the switchboard (only using SaveProg) for automatic time band management of Indoor / Outdoor modes. This function is only available if the "Competence Areas" function is disabled (see paragraph below).
The function is applied independently to each switchboard. Management is simplified and consists of dividing the days of the week into two groups: Weekdays (Monday to Friday) and
Weekend (Saturday and Sunday). Each group is then divided into two time bands delimiting the start and end times for the service. When the current time falls within a time band, the switchboard will operate in Indoor mode. When it falls outside a time band, the switchboard will operate in Outdoor mode.
If automatic mode is enabled, the symbol will appear on the first line of icons and the switchboard operator will not be able to manually switch between Indoor and Outdoor mode, except just to temporarily suspend Indoor mode status. Indoor
mode status can be suspended by pressing
and then indicating the suspension time period in minutes. The
maximum time period is fixed at 30 minutes. During this period, the icon turns red (
) to indicate the situation.
The return to Indoor mode occurs:
1. Automatically on expiry of the set time period
2. If the time band changes during the set time period
3. If the switchboard operator repeats the above procedure, entering "0" as the time period.
28
7” Due Fili Plus porter switchboard
Competence Areas (CA)
A Related Zone, hereinafter CA, is an extension of the Indoor / Outdoor mode of the switchboard and automatic Indoor / Outdoor mode.
CAs are configured exclusively using Project Mode of the SaveProg software. When they are configured, the
key
will have no effect. Strictly speaking, the CA consists of a list of:
1. Indoor units only
2. Speech units only
3. Indoor and speech units
which are served by the switchboard. The CA definition must be identical for all the switchboards in the same installation.
The CAs are subsequently associated with the day/s of the week (or holidays), and for each of these to time bands with subdivisions of 30 minutes.
In each of these three cases, the management procedure is as follows:
1. The indoor units that make a call to a generic switchboard are served by all the switchboards that have those units in an active CA. Calls purposely originated from indoor units are served in any case.
2. Calls originating from the indicated speech units and directed towards any switchboard, are managed by the switchboards that have those speech units in an active CA.
3. Calls originating from one of the speech units in the list AND SIMULTANEOUSLY directed to one of the indoor units in the list are served by all those switchboards that have both of them in an active CA.
Call Filter
When the call filter is enabled, the switchboard will no longer receive calls from indoor units. Two separate filters can be configured. The Indoor Call Filter, if enabled, is applied when switchboard is in Indoor mode. Conversely, the Outdoor Call Filter, if enabled, is applied when switchboard is in Outdoor mode. The two filters can be enabled and disabled indepen-
dently of each other, but only using SaveProg. When a filter is active, the icon
appears alongside the relative Indoor/
Outdoor mode icon.
Programmable keys
Keys and are programmable and by default respectively execute commands F1 and F2 for the speech unit in conversation. In standby, the commands are sent to the last speech unit which was contacted or which called.
The keys can only be programmed using SaveProg. The programmable functions are: intercom, self-start, auxiliary function activation, F1 function, F2 function, lock activation.
Dial a number and then press the
key to command the F1 output of the speech unit corresponding to the number
dialled. Similarly, dial a number and then press the
key to command the F2 output of the speech unit corresponding
to the number dialled. This function is executed independently of the function programmed using SaveProg.
Search contacts list
Press the key to access the contacts list in List display mode. For each element, the ID of the speech unit (possibly preceded by the √ symbol, if it is the main name associated with that
29
VIMAR group
7” Due Fili Plus porter switchboard
ID) is shown in the left-hand column, and the user name in the right-hand column. The list is organised alphabetically and can be scrolled using the keys
and .
Press
to toggle between List display and Detail display.
List display
Detail display
Detail display with remapping active
In this mode the left-hand column remains unchanged, while the following detailed information relating to the selected ele­ment appears in the right-hand column:
• ID of the indoor unit (possibly preceded by the √ symbol, if it is the main name associated with that ID), remapping code (if included in the contacts list and active in the switchboard), stairway location (if specified in the contacts list).
• Name of the building in which the indoor unit is located (if specified in the contacts list).
• User name associated with the indoor unit.
• Any user information and/or second name (if specified in the contacts list).
The selection in the left-hand column can be moved to the previous or subsequent line using keys
and . The
right-hand part is updated accordingly.
In List mode the elements in the contacts list displayed on the screen can be filtered by typing the initial part of the name
you are searching for. To do this, use keys
- with the multi-tap method. For example, if you press key
(letter “E”) twice, then key (letter “L”) three times, the filter “EL” will be applied, meaning only the elements
with a name beginning “EL” will be displayed.
The filter is displayed on the left of first line at the top, after the icon
. During entry, the characters appear in grey; shortly
after the last keystroke (multi-tap timeout), they turn white and the filter is applied.
30
7” Due Fili Plus porter switchboard
If none of the elements in the contacts list match the entered filter, the message CONTACTS LIST EMPTY appears on the screen.
Once the filter has been applied, you can still scroll through the filtered list using the keys
and .
Pressing the key
deletes the last character in the filter. The updated filter is then applied but the selected line is not
changed.
When the filter is empty, pressing the key
closes the contacts list. When the filter is enabled, you can close the
contacts list by pressing
for at least 0.5 seconds.
Multitap
KEY SYMBOL
1 1.,:;?!()<>
2
ABC2abc
БАВГЕДЖЗбавгеджз
3
DEF3def
ĐЙИКЛрйикл
4
GHI4ghi
НМОПнмоп
5 JKL5jkl
6
MNO6mno
СсУТФХЦШутфхцш
7
PQRS7pqrs
ß
8
TUV8tuv
ЪЩЫЬъщыь
9
WXYZ9wxyz
Ýý
0 <space>0_$&*#+-=/%” ‘
Lock
Press and release the key to send the open lock command to the speech unit with which conversation is taking place. In standby, the command is sent to the last speech unit which was contacted or which called.
Dial a number and then press the
key to send the command to the speech unit corresponding to the number dialled.
Dial a number and then hold pressed the
key for 0.5 seconds to send the activation command to the relay corre-
sponding to the number dialled.
Press and hold
for 0.5 seconds; if programmed, the activation menu opens. If the menu is not programmed, a
warning tone is emitted. Select the desired activation from the list using the
and keys. Then press the
key to carry out the activation, or
to exit the menu. The menu also closes in the event of prolonged inactivity.
31
VIMAR group
7” Due Fili Plus porter switchboard
Activations menu
The
key also works in the same way during conversation with the speech unit.
This function can only be programmed using SaveProg.
Self-start
Briefly press the key to send the self-start request to a speech unit, in accordance with the sequence programmed on the master speech unit in the system. Subsequent presses advance the sequence, allowing the cyclical activation of several speech units.
Dial a number and then press the
to request the specific self-start of the speech unit corresponding to the number
dialled.
Press and hold
for 0.5 seconds; if programmed, the self-start menu opens. If the menu is not programmed, a warn-
ing tone is emitted. Select the speech unit or CCTV camera for which you wish to request self-start from the list using the keys
and . Then press to request the self-start, or press to exit the menu. The menu also closes in
the event of prolonged inactivity.
Self-start menu
The
key also works in the same way during conversation with the speech unit.
The self-start function is always started with the microphone muted but the loudspeaker enabled, in order to hear the audio coming from the speech unit.
This function can only be programmed using SaveProg.
32
7” Due Fili Plus porter switchboard
Events list
When there is at least one event that is not served, the icon will flash at the top right of the screen.
Events notification
The switchboard saves the following events in memory (the type under which they are classified is shown in brackets):
1. Calls unanswered by the switchboard, i.e. missed calls (EVENTS).
2. Calls purposely rejected by the switchboard (EVENTS).
3. Lock activations (LOCK).
4. Relay activations (RELAY).
5. Door open notification (DOOR OPEN).
6. Door closed notification (DOOR CLOSED).
7. F1 activation (F1)
8. F2 activation (F2).
To access the list, press the
key: the most recent event will be shown (indicated by the number 1). Use the keys
and to scroll through the list, ordered from the most recent to the least recent event. To close the display, press
the
key or wait for the inactivity timeout to elapse.
To delete the entire list of events, press and hold the key
for at least 0.5 seconds, then enter the installer PIN. It is not
possible to delete a single event.
The display includes the following information. On the first line, on the left, the type of event. On the right, indicated in the format I / T (N): the index of the event displayed
(I), the total number of events in the list (T) and the number of events not yet served (N). The date and time of the event is indicated on the second line, in blue and in the configured format. On the third line, in the case of EVENTS, the message NOT SERVED is displayed, or alternatively the date and time when
the event was served. For details see the next paragraph, Events service. The fourth line displays information relative to the source of the event: a symbol followed by the user identification number
and, if applicable, name. It may be an indoor unit
, a speech unit , or another system device, such as a relay, for
example
.
The fifth line displays information relative to the destination of the event or additional generic information. For example, the
symbol
to indicate a switchboard, or for an indoor unit, followed by an identification number, and, if applicable, a
name.
33
VIMAR group
7” Due Fili Plus porter switchboard
Call to switchboard from indoor unit, not
answered
Call to switchboard from indoor unit, rejected
Call to switchboard from speech unit, not
answered
Call to switchboard from speech unit, rejected
Call from speech unit to indoor unit 1, with
switchboard in "Indoor" mode, not answered
Call from speech unit to indoor unit 1, with
switchboard in "Indoor" mode, rejected
34
7” Due Fili Plus porter switchboard
Call to switchboard from indoor unit, previously
not answered and then served
Call to switchboard from indoor unit, previously
rejected and then served
Lock opening
Relay activation
Door opened
Door closed
Alert
Alerts are notifications that indoor units can send to the switchboards. These notifications can also be sent even if the Bus is occupied with a call in progress. When a switchboard receives an alert, it emits a warning tone and enters the new event in the list of Alerts.
When there is at least one event that is not served, the icon
will flash at the top right of the screen.
To access the list of alert notifications, press
: the most recent event will be shown (indicated by the number 1). Use
the keys
and to scroll through the list, ordered from the most recent to the least recent event. To close the
display, press the
key or wait for the inactivity timeout to elapse.
35
VIMAR group
7” Due Fili Plus porter switchboard
Alert notification
"Not served" alert
"Served" alert
The number to the right of the symbol # is the sub-address associated with the indoor unit (it could, for example, indicate the bathroom instead of the bedroom), whereas the number after CNT indicates the number of times the indoor unit has sent the request.
To serve the alert, the switchboard operator must open the list and call the indoor unit using the
key or by lifting
the handset.
Service of similar events (missed or rejected calls)
When a user is recalled, all the similar elements i.e. missed or rejected calls, that originate from the same indoor unit are
marked as served. The user is recalled simply by pressing the
key or by lifting the handset.
The event from which the call is made is marked as served directly. In this case, the date and time of the service are shown in light green.
The other events are marked as served indirectly. In this case, the date and time of the service are shown in dark green.
It is possible to mark an event (and all similar events) as served by holding pressed the key
for 0.5 seconds. In this
case, the selected event will also be marked as served indirectly. Note: missed or rejected calls are marked as served indirectly even if the call comes from outside the events list.
Events list filter
The information shown in the events list can be filtered. When the list is first opened, no filters are applied. Press to cycle between the three possible displays, which are indicated by the icon at the top left, above the events list:
• No icon means no filter.
36
7” Due Fili Plus porter switchboard
• for filter active (see below for details on what is displayed and what is not).
•
for filter active and limited to events not served (see below for details on what is displayed and what is not).
In the second and third case, additional information may be added to further restrict the criteria for the type of events dis­played. If no further information is added, the filter shows all events, as if no filter were applied.
After the icon there may be a number that represents the ID of an indoor unit or a switchboard. This will be the only device
for which events are displayed. To enter this number, hold pressed
for 0.5 seconds, then enter the device ID. To
cancel the ID filter, type 0 and confirm with
.
Note: non-extended switchboards have IDs in the range 201 to 204. Extended switchboards range from 40001 to 40128 for vertical systems and from 40129 to 40144 for horizontal systems.
Further filters may then be activated, depending on the configuration of the switchboard. Filters can in fact only be activated if the switchboard is enabled to record them (see SaveProg).
They will be shown on the first line of the display, to the right of the filter icon and the ID (if present), in the order indicated in the following table, regardless of the order in which they were activated. Each filter present indicates show also the relative event. Note that no filter is managed as show all. Each press of the key causes the relative icon to appear or disappear.
KEY ICON MEANING
Missed calls
Denied calls
Door open / closed
Lock
F1
F2
Relay
Use the keys
and to scroll through only those events that meet the filter criteria. Note. The line P / T / (N) continues to always show the same values. If a filter does not return any events, the indication LIST EMPTY is displayed.
37
VIMAR group
7” Due Fili Plus porter switchboard
Minimum conductor cross-section (mm
2
)
Lock 1.5 mm
2
Other specifications:
-, +U, +I (β)
1 mm
2
(β) the additional power supply unit 6923 must be installed as close as possible to the device to which it is to be connected.
* BUS TERMINATION FOR DUE FILI PLUS INSTALLATIONS
This note applies to all devices equipped with “BUS termination connector or dip-switch”, which is identified by the screen-printed letters “ABC” and marked on the wiring diagrams with *. For correct adaptation of the line, make the setting ac
-
cording to the following rule:
- Maintain position “A” if the BUS enters and exits from the device;
- Move to position “B” (if Elvox cable) or to position “C” (if CAT5 twisted pair cable) if the BUS line terminates in the device itself.
Installations with passive distributor 692D.
ALWAYS use output 1 of distributor 692D (the only output that does not have a termination jumper). For termination of the distributor 692D:
- If the “OUT” outputs “2”, “3” or “4” are not to be used, MAINTAIN the jumper on the connector “TOUT”, “T2”, “T3” or “T4”.
The default “TOUT” connector is in the “100” position
(Elvox cable), position it at “50” only if using a CAT5 twisted pair cable.
Installations with active distributor 692D/2
The termination jumper must be positioned on “B” (for Elvox cable) or on “C” (for CAT5 twisted pair cable) IF AND ONLY IF the BUS terminates at the device itself. It must be left on “A” if effecting entry-exit using terminals 1-2 on 692D/2.
A” =
No termination “B” = 100 Ohm termination “C” = 50 Ohm termination
**
Important:
Strictly observe the connections on the connecting stud. Inverted wiring connections may lead to the switchboard being damaged.
Installation diagrams
38
7” Due Fili Plus porter switchboard
Video door entry system in apartment block with multiple external entrance panels, porter switchboard and floor distributor
D - Pixel series button video door entry panel D0 - Pixel series alphanumeric video door entry panel K - Door call button L - 12 V Electric lock P - Door release control
SC_02_DF_015
+U +I
PRI
Alimentatore
-
Rete
+12
CH
1 2
E+
E-
FP
M
A B C
6S 6P
A B C
VIDEO
T1
T2
T3
T4
4 5
+
2
1
-
Distributore
3B3AT4IN 4B4A
T3
2B2A OUT 1B1A
TOUTT2
+12
CH
1 2
E+
E-
FP
M
A B C
*
M V3 13 12
1 2 3 4
C B A
2 B1B2
PRI
Alimentatore
1
Rete
Concetratore
B2B1
1 2
IN1 IN2 IN3 IN4
B2B1 B2B1 B2B1
OUT1 OUT2
1 2
+U +I
PRI
Alimentatore
-
Rete
+U +I
PRI
Alimentatore
-
Rete
K
K
K
K
*
*
*
*
Monitor 7549
Monitor 7539
2 1
A B C
FP
M
K
B1 E+ E­CA
M S+ S-
F1+
F1-
CA+ CA-
B2
5V+
5V-
CA+ CA-
L
P
D0
B1 E+
E-
CA­S+
S-
B2
CA+
P
D
L
B1 E+
E-
CA-
S+
S-
B2
CA+
P
D
L
B1 E+ E-
CA-
S+ S-
B2
CA+
P
D
L
40510
2 1
~ ~
Centralino
**
*
Cavo 732H 732I
Cavo 732H
732I
Cavo 732H
732I
692D
Monitor 6209 6029+ 6145
Monitor 6329
6922.1
69MX
6923 6923
21
OUT
Montante
6923
Monitor 7211
Monitor 6611 6711 661C
Monitor 6621 6721 662C
Monitor 5721
Monitor 7311 7321
Cavo 732H 732I
Monitor
7311 7321
Monitor
6611 6711 661C
Monitor
6621 6721 662C
Monitor
5721
Monitor
7211
Monitor
7539
Monitor
6029 + 6209 + 6145
Monitor
6029/C + 6209 + 6145
Monitor
6329 6329/C
Distributor
Cable
732H 732I
Cable
732H 732I
Cable
732H 732I
Mixer
Switchboard
Monitor
7549
Cable
732H 732I
Power supply
Power supply
Power supply
Power supply
Mains
Mains Mains Mains
Cable riser
OUT
39
VIMAR group
7” Due Fili Plus porter switchboard
Video door entry system in building complex with 4 porter switchboards
C - Pixel series button audio door entry panel D - Pixel series button video door entry panel D0 - Pixel series alphanumeric video door entry panel L - 12 V Electric lock P - Door release control
SC_02_DF_028
2 B1B2
PRI
Alimentatore
1
Rete
2 1 2
Separatore
121
BUS D BUS P
C B A
D
692S
6922.1 69MX
6922.1
692S
6922.1 692D
* *
Concetratore
B2B1
1 2
IN1 IN2 IN3 IN4
B2B1 B2B1 B2B1
OUT1 OUT2
1 2
2 B1B2
PRI
Alimentatore
1
Rete
2 B1B2
PRI
Alimentatore
1
Rete
2 1 2
Separatore
121
BUS D BUS P
C B A
D
Distributore
3B3AT4IN 4B4A
T3
2B2A OUT 1B1A
TOUTT2
Concetratore
B2B1
1 2
IN1 IN2 IN3 IN4
B2B1 B2B1 B2B1
OUT1 OUT2
1 2
69MX
*
B1 E+ E-
CA+
CA-
S+ S-
F1+ F1-
CA+
CA-
B2
5V+ 5V-
CA+
CA-
L
P
D0
B1 E+
E-
CA­S+
S-
B2
CA+
P
D
L
B1 E+ E-
CA-
S+ S-
B2
CA+
P
D
L
B1 E+ E-
CA-
S+ S-
B2
CA+
P
C
L
6923
40510
40510
Distributore
3B3AT4IN 4B4A
T3
2B2A
OUT 1B1A
TOUTT2
*
6923
6923
40510
692D
+U +I
PRI
Alimentatore
-
Rete
2 1
~ ~
Centralino
**
+U +I
PRI
Alimentatore
-
Rete
2 1
~ ~
Centralino
**
+U +I
PRI
Alimentatore
-
Rete
2 1
~ ~
Centralino
**
40510
6923
+U +I
PRI
Alimentatore
-
Rete
2 1
~ ~
Centralino
**
1 2
Montante
12
Montante
12
Montante
Cavo 732H
732I
Cavo 732H 732I
Cavo 732H 732I
Cavo 732H
732I
Cavo 732H 732I
Cavo 732H 732I
Cavo 732H
732I
Cavo 732H
732I
Cavo 732H
732I
Cable
732H 732I
Mixer Separator
Cable
732H 732I
Distributor Separator
Cable
732H 732I
Cable
732H 732I
Mixer
Switchboard
Cable
732H 732I
Cable
732H 732I
Cable
732H 732I
Distributor
Alimentatore
Switchboard
Switchboard
Switchboard
Power supply
Power
supply
Power supply
Power supply
Power supply
Power supply
Power supply
Mains Mains
Mains
Mains Mains
Mains Mains
Cable riser Cable riser
Cable riser
Cable
732H 732I
Cable
732H 732I
Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
49400857A0_MI 00 16 07