ELVA 1 MICROWAVE HANDELSBOLAG PPC 10G E User Manual

Copyright © 2016, ELVA-1 All information f rom this Manual is protected by the related copyright,
patent, ELVA
improve performance or usability of the described products. PPC
1. All other trademarks or product
names
PPC-10G User Manual Rev.1.0
10 Gigabit Ethernet Wireless Link
Point-to-Point Connectivity
PPC-10G
40.5 – 43.5 GHz 71-76/81-86 GHz
or intellectual property right.
-1 has the exclusive right to change this information in order to
-10G is a trademark of ELVA­are the property of their respective owners.

© ELVA-1, 2016. All rights reserved.

PAGE 2
РРС-10G USER MANUAL
1 Statement of Warranty 3
1.1 Product Compatibility 3 2 Safety Precautions 4 3 Product Code Format 4 4 PPC-10G Overview 5
4.1 PPC-10G Features 5
5 Package Contents 6 6 Site Preparation 7
6.1 Path planning 7
6.2 Minimum Clearance for Fresnel zone 7
6.3 РРС-10G System Diagram 8
6.4 Stationary Cabling on Installation Site 9
6.5 Switching radios to installation mode 10 7 Transceiver Installation on Site 11 8 Final Antenna Alignment 14 9 Using WEB Monitoring 16 10 Maintenance and Troubl esho ot ing 19 11 Specifications and Dr awing 20
PAGE 3
PPC-10G USER MANUAL

1 Statement of Warranty

Elva-1 warrants each product sold by it to be free of defects in material and workm anship under conditions of normal use for twelve (12) months from date of receipt thereof to Bu yer. Repair or, at Elva­1’s option, replacement of defective parts shall be the sole and exclusive remedy under this limited warranty. All warranty replacement or repair of parts shall be limited to equipment malfunctions, which, in the sole opinion of Elva-1, are due or traceable to defects in original materials or workmanship.
In the event the Buyer believes that the Product is covered by the limited warranty of this Section, the Buyer shall pay for the s hipping and insurance of such Pro duct to Elva-1. If Elva-1 determines in its sole opinion that s uch Product does conform to the limited warrant y, then Elva-1 shall pay for the shipping and insurance of repaired or replacement Product back to the Buyer. However, in the event that Elva-1 determ ines in its sol e opinion that s uch Produc t is not cov ered by the limited warranty, Buyer shall pa y for shi pping a nd insurance of such Product back to the Buyer.
All obligations of Elva-1 un der this limited warrant y shall cease in the event of abuse, acci dent, a lterat ion, m isus e or negl ect of the Pro duct. In-warranty repaired or replaced parts are warranted only for the remaining unexpired portion of the orig inal warr anty period applicab le to the repaired or replaced parts.
REASONABLE CARE MUST BE USED TO AVOID HAZARDS. ELVA-1 EXPRESSLY DISCLAIMS RESPONSIBILITY FOR LOSS OR DAMAGE CAUSE D BY USE OF IT S PRODUCT S OTHER T HAN IN ACCORDANCE WITH PROPER OPERATING PROCEDURES.
THE FOREGOING LIMITED WARRANTY FOR ELVA-1 PRODUCTS IS EXPRESSLY IN LIEU OF, AND EXCLUDES ALL OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND OF FITNESS FOR PARTICULAR PURPOSE, USE OR APPLICATION, AND ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF ELVA-1 MILLIMET ER WAVE DIVISION, UN LESS SUCH OT HER WARRANTIES, OBLIGATIONS OR LIABILITIES ARE EXPRESSLY AGREED TO IN WRITING BY ELVA-1.
Statements made by any person, including the representatives of Elva-1, which are inconsistent or in conflict with the terms of these warranties shall not be b inding upon Elva-1 unless expres sly reduc ed to writing and approved by CIO of Elva-1.
Do not install substitute pa rts or perform any unauthorized repair or modification to the equipment. Any repair, changes or modifications not expressly approved by Elva-1 void the Warranty on the equipment.

1.1 Product Compatibility

While every effor t has been made to verif y operation of this Product with many different communications products and networks, Elva-1 makes no claim of compatibility between its products and other vendors’ equipment. It is assumed that users have thoroughly evaluated this product’s performance in the communications environment in which it wil l be used.
PAGE 4
РРС-10G USER MANUAL

2 Safety Precautions

The following general safety precautions must be observed during all phases of operation and service of the ELVA-1 products. Elva-1 assumes no liability for the customer’s failure to comply with these requirements.
This product is not designed to withstand a direct lightning strike. It should be operated only with the protection of an external lightning rod.
Do not operate wireless equipment without an appropriate termination.
Do not work directly in front of energized antenna. Prior to working on the antenna or RF assembly, ensure that the RF assembly is not radiating energy. When power is applied to the RF assembly and antenna, power precautions must be taken to avoid placing any part of the human body in front of the antenna.
The outdoor equipment must be properly grounded to provide protection against voltage surges and built-up static charges. In the event of a short circuit, grounding reduces the risk of electrical shock.
For installations in the USA, refer to Articles 810830 of the National Electrical Code, ANSI/NFPA #70, for information with respect to proper grounding and applicable lightning protection for DC cables. For installations in all other countries, implement protection in accordance with the safety standards and regulatory requirements of the country where the equipment is to be installed.
Do not install or operate this equipment in the presence of flammable gases or fumes. Operation of any electrical instrument in such an environment constitutes a definite safety hazard.
This product is designed to withstand moisture conditions typically encountered when installed outdoors. This is not designed for operation under water.
This product should be operated only from the type of power source indicated on the unit or in manual.

3 Product Code Format

For example, PPC-10G link with 2ft antennas, 40.5 – 43.5 GHz frequency band has produc t code PPC-10G-Q-2ft.
PAGE 5
PPC-10G USER MANUAL

4 PPC-10G Overview

The РРС-10G wireless link is intended for full duplex 10 Gigabit Ethernet radio comm unication between two locations. It is comprised of two subscriber transceivers, each operating under line-of-sight conditions at working frequencies within the 71/86 GHz or
40.5-43.5GHz radio bands. This link is intended for point-to-point digital communications
applications such as 4G/LTE/5G Mobile Backhaul, Corporate Campus Networks, IPT V, and Wireless ISP back bone s. It is designed to wirelessly interconnect WAN/LAN segments that are located at sites with no fixed line broadband connection. Such sites typically contain landscap e or i ndus t rial b ar riers , or strict ecological restrictions for ground cable trenching, like national parks, rivers, lakes, airport/railway areas, private land, etc.
PPC-10G is available i n either licensed 40.5-43.5 G Hz (Q-band) or lightly licensed 71/86 GHz (E-band) frequency formats. The radios are equipped with 60 cm (2 ft.) antennas by default; however, smaller antenna sizes ar e also available. The P PC-10G is normally mounted in a rooftop or tower location, and contains slots for SFP/SFP+ modules to connect to a LAN/WAN network.
The ELVA-1 PPC-10G is a fully-outdoor radio link, designed for temperature variations between -50°C(-50F) and +65°C(150F), and humidity up to 100%. T he reliable o perating dist ance is up to 10 km (6 mi) for link s equipped wi th 60 cm antennas . This distance is valid for regions like North America or continental Europe. For regions with clear weather year-round, like the Middle East, the distance would be much longer.

4.1 PPC-10G Features

• Frequency band: 40.5-43.5 GHz or 71-76/81-86 GHz
• SNMP v.1; v.2; v.3; MIB-II and DOK Ent er pris e MIB; WEB
• True Full Duplex Operation
• Hitless adaptive bandwidth, coding and modulation
• IEEE 1588v2, SyncE
• Secure communication due to the difficulty of intercepting the link’s laser-like beam transmission in free air without detection
• Solid reliability with Fiber-like Performance
• Easily installed, zero-footprint
• Compact Cassegrain type antennas
• Quasi-optical (laser-like) millimeter wave propagation
• EMI interference free
PAGE 6
РРС-10G USER MANUAL

5 Package Contents

The PPC-10G equipment will arrive in 3 boxes (photo at left), the sizes of which will depend on requested antenna diameter.
Two of the boxes will cont ain the antennas a nd mounting/alignment brackets, and the other box will contain two transceivers and accessories (cables, connectors, tools, etc.).
Each antenna box will contain one antenna, an anten na cover and a mounting/alignment bracket. Depending on the antenna configuration, the alignment bracket could already be mounted to the anten na as a complete unit (below, lef t photo) or be enc losed in the box as separate accessory package (below, right photo).
If the alignment bracket is enclosed in a separate accessory package, it must be assembled and mounted to antenna in accordance with the printed manual that is enclosed in the box.
The box with transceiver s contains 3 smaller boxes ins ide. Two of them contain transceivers (below, left photo) and one with doubled kit of power units, cables, sockets, tools, attenuation m eter (below, right photo).
The factory recommends that the shipping boxes and packing materials be r etained by the customer at least for the length of the warranty (12 months), or longer.
PAGE 7
PPC-10G USER MANUAL

6 Site Preparation

The PPC-10G mm-wave wireless link requires a c lear Line-of-Sight (LOS) for proper operat ion. That means that no obstacles, s uch as trees, buildings, chim neys, etc. can obstruct th e LOS path between the transceivers. Moreover, no obstacles should be located in the vicinity of the signal propagation line (inside the first Fresnel zone).
Site planning should inc lude an investigation into futu re construction that would block the LOS path, and other long term incremental obstructions such as growing trees.
Because the link distances are usually within 10 km obstructions in the path can easily be identified using binoculars. It is important to understand that the Line-of-Sight is not just a thin line but more closely resembles a cone. To avoid si gna l d egradation within th e F irs t Fresnel Zone, no obstacles should be located within a 1-4.5 meter (1.2-14.7 ft.) radius around the center axis of the Line-of-Sight.

6.1 Path planning

Use Google Maps or another geograph ical locating tool to obta in the exact distance between the proposed transceiver installation points.
Contact your ELVA-1 representative to obtain the exact attenuation value for the transc eiver distance obtained above. T his value will be your “passport” reference value on the attenuation meters when conducting the final antenna alignment.

6.2 Minimum Clearance for Fresnel zone

There must be no obstructions between the antennas in the so-called first Fresnel zone. An y obst ruc tion in the first Fresnel zone will corrupt the antenna pattern. In practice, the antenna should be m ounted on the edge of a roof or on a mast, so it propaga tes the signal directly into free space.
Loading...