Elumen8 ELUM042, ELUM042A, ELUM042D User Manual

50W/100W LED Zoom
User Manual
Code: ELUM042 - 50W - (5600K) Code: ELUM042A - 100W - (5600K) Code: ELUM042D - 100W - (3200K)
1
2
You should nd inside the Elemen8 carton the following items:
1, LED Zoom 2, Instruction manual, 3, Power Cable
Technical Specications:
DMX channels: 1 or 3 selectable 1 x 50W or 100W White LED (5600K or 3200K) Dimming, master/slave and DMX modes 400Hz refresh rate 5-pin XLR in/out sockets 4 push button menu with LCD display Powercon in/out sockets Beam angle: 10-50 degrees Power supply: 100-240V~50/60Hz Power consumption: 50W version - 77W Power consumption: 100W version - 126W Dimensions: 350 x 165 x 255mm Weight: 50W version - 4.6Kgs Weight: 100W version - 5Kgs
Operating modes: 1, Dimming 0-100% 2, DMX 3, Master/slave 4, Channel select 5, Dimming curves
50W Back
Note: To use the focus knob on the rear of the 100W xtures, simply turn the knob counter clock wise to zoom in (s) and turn it clockwise to zoom out (L).
100W Back
MENU
POWER IN POWER OUT
FUSE
F2A~250V
ENTER
LCD DISPLAY
UP DOWN
DMX OUT
DMX IN
3
MENU
DMX IN
POWER IN POWER OUT
FUSE F2A~250V
DMX OUT DMX IN DMX OUT
ENTER
LCD DISPLAY
UP DOWN
100W LED ZOOM COOL WHITE
FOCUS
S L
4
Operation:
1, Dimming Mode
To enter the dimming mode, press the “MODE” button to show “DIMMER” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to set the brightness from 00-99. Now press the “ENTER” button again to add strobe and use the “UP” and “DOWN” buttons to change the ash speed from 00-99.
NOTE: C:99 = Dimming (00 = off, 99 = full on), F-99 = Flash (00 = off, 99 = fast)
When you are happy with your choice, press the “ENTER” button to conrm it.
2, Slave Mode
To enter slave mode, press the “MODE” button to show “SLAVE” on the LCD display. Now the unit will follow in sequence with the master unit.
3, Dimming Curve Mode
The LED Zoom includes two sets of dimming curves. The rst is a Halogen emulation mode with a very smooth slow dimming and a small delay. The second is an LED response with faster dimming and no delay.
To enter the dimming curve mode, press the “MODE” button to show “DIMMER CURVE” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to select between the 4 dimming curves from 01-08.
1-4 are for halogen response type : 01 = Linear, 02 = Square, 03 = Inverse square, 04 = S-curve. 5-8 are for LED response type : 05 = Linear, 06 = Square, 07 = Inverse square, 08 = S-curve.
When you are happy with your setting, press the “ENTER” button to conrm it.
LINEAR: the increase in light intensity appear to be linear as DMX value is increased. SQUARE: light intensity control is ner at low levels and coarser at high levels INVERSE SQUARE: light intensity control is coarser at low levels and ner at high levels S-CURVE: light intensity control is ne at low levels and high levels and coarser at medium levels.
4, Channel Mode
To enter the channel mode, rst press the mode button to show “CHANNEL” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to select 1 or 3 channel mode.
5, DMX Mode To enter the DMX mode, press the “MODE” button to show “DMX MODE” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to select the DMX address from 001-512.
When you are happy with your setting, press the “ENTER” button to conrm it.
DMX Charts
1 channel mode:
Channel
CH1
Value
0-255
Function
Dimming 0-100% using the curve set on the xture
5
DMX Charts
3 channel mode:
DMX-512:
• DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent xtures and controllers. A DMX controller sends DMX data instructions form the controller to the xture. DMX data is sent as serial data that travels from xture to xture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX xtures (most controllers only have a data “out” terminal).
DMX Linking:
• DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX xtures try to use the shortest cable path possible. The order in which xtures are connected in a DMX line does not inuence the DMX addressing. For example; a xture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a xture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
DATA Cable (DMX cable) requirements (for DMX operation):
• The LED Zoom can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin or 5-pin XLR connector for data input/output (gure 1).
Figure 1
Also remember that DMX cable must be daisy chained and cannot be split.
Channel Value
0-255
0-255
0-15
16-45
46-75
76-105
106-135
136-165
166-195
196-225
226-255
CH1
CH2
CH3
Function
Dimming 0-100%
Strobe speed (slow to fast)
Dimmer curve and response select on xture
Dimmer curve Linear response halogen
Dimmer curve Square response halogen
Dimmer curve Inverse Square response halogen
Dimmer curve S response halogen
Dimmer curve Linear response LED
Dimmer curve Square response LED
Dimmer curve Inverse Square response LED
Dimmer curve S response LED
Notice:
• Be sure to follow gures 2 & 3 when making your own cables. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behaviour.
Special Note: Line termination:
• When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour.
Using a cable terminator (part number CABL90) will decrease the possibilities of erratic behaviour.
5-Pin XLR DMX Connectors:
• Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-Pin XLR xtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used. The Chart below details the correct cable conversion.
Termination reduces signal transmission problems and interferance. it is always advisable to connect a DMX terminal, (resistance 120 Ohm 1/4 W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture.
6