ELTA FANS Mori HR Installation Manual

Page 1
Introduction
MORI HR is a continuously running, alternate flow supply and extract fan with heat retention for use in habitable rooms such as; living rooms, bedrooms, dining rooms basements and hallways. It is designed to ensure adequate ventilation in enclosed environments. It is recommended that two units are installed in a pair: when one unit is pulling, the other is pushing. A pair of units can be installed in the same room or in different rooms (i.e. living room and bedroom). The unit is suitable for installation on an outside wall.
Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel. The manufacturer assumes no responsibility for damage to persons or property resulting from failure to observe the regulations contained in this booklet.
• Inner ventilation unit material: high quality, impact and UV-resistant ABS colour RAL 9010.
• Design front cover removable for cleaning without the use of tools.
• Easy maintenance installation plate, for easy access to the heat exchanger from inside the room.
• Anti-dust filter, easily removable for washing by the user without tools.
• Regenerative honeycombs ceramic heat exchanger.
• External grille in high quality, impact and UV-resistant ABS colour RAL 9010.
• High efficiency aerodynamic fan with “winglet” blades to optimise quietness and efficiency.
• Single phase EC reversible Brushless motor with integral thermal protection.
• Motor mounted on high quality ball bearings.
• The unit is double insulated: no earth connection is required.
• Trickle speed selectable.
• Boost mode.
• Free-cooling (Bypass) mode.
• IPX4 degree of protection.
• Power supply 220V to 240V~ 50Hz.
• The device should not be used for applications other than those specified in this manual.
• After removing the product from its packaging, verify its condition. In case of doubt, contact a qualified technician. Do not leave packaging within the reach of small children or people with disabilities.
• Do not touch the appliance with wet or damp hands/feet.
• The device is not intended for use by persons (including children) with reduced physical, sensory or mental capacities or those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the device from a person responsible for their safety. Children should be supervised to ensure that they do not play with the device.
• Do not use the product in the presence of inflammable vapours, such as alcohol, insecticides, gasoline, etc.
• If any abnormalities in operation are detected, disconnect the device from the mains supply and contact a qualified technician immediately. Use original spare parts only for repairs.
• The electrical system to which the device is connected must comply with regulations.
• Before connecting the product to the power supply or the power outlet, ensure that:
- the data plate (voltage and frequency) correspond to those of the electrical mains
- the electrical power supply/socket is adequate for maximum device power. If not, contact a qualified technician.
• The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot air/fume vent ducts deriving from
Installation manual Mori HR
TECHNICAL SPECIFICATIONS
PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE
G
To achieve the best possible ventilation the unit should operate continuously, and only stopped for maintenance or service.
When heat exchange is not useful (for example in mid-seasons when indoor and outdoor temperatures are similar) it is
recommended to set the unit in “extract-only” or “intake-only” mode and not switch the fan off.
Model Airflow l/s Power W Weight Kg
Mori HR 100 2,8/4,2/7 1,2/1,7/2,6 2
Mori HR 150 5,6/11,1/16,7 1,4/2,3/3,8 4,2
G
Page 2
2
Every 70 seconds the unit alternates between being a supply fan and an extract fan. During the extract mode the units high efficiency heat exchanger collects and retains heat from the extracted air, it then transfers the majority of this heat to the incoming air during supply mode, recovering most of thermal energy which would be otherwise lost in the ventilation process. The unit can be run continuously at a set speed by adding an internal link, or controlled via the dedicated controller, 149-SEN-CTRLS which allows speed selection and triggering of free cooling mode.
S3 switch activates the “Free cooling “ (Bypass) mode , which stops alternate flow and keeps the fan in “extract-only” or “intake-only” mode, to avoid the heat exchange when necessary. To set the extract-only” mode or “intake-only”, place the integral jumpers as per Fig.20A or Fig.20B). The front cover LED indicates when the Free cooling mode is on. An automatic “Boost”mode can be achieved through a dedicated switch. Wiring configurations:
1. Constant run with alternate flow and heat retention on Speed 1 only – See diagram 18A.
2. Constant run with alternate flow and heat retention on Speed 2 only – See diagram 18B.
3. Constant run with alternate flow and heat retention on Speed 3 only – See diagram 18C.
4. Constant run with alternate flow and heat retention on Speed 1 with boost to Speed 3 triggered by external switching device (ordered separately if required) – See diagram 18D.
5. Constant run with alternate flow and heat retention on Speed 2 with boost to Speed 3 triggered by external switching device (ordered separately if required) – See diagram 18E.
6. Operation using controller 149-SEN-CTRLS (ordered separately if required) – See diagram 18F. (a) Off. (b) Constant run with alternate flow and heat retention on Speed 1. (c) Constant run with alternate flow and heat retention on Speed 2. (c) Constant run with alternate flow and heat retention on Speed 3. (d) Constant run on selected speed in extract or supply mode only (supply or extract selectable at installation stage). Please note that this switch can control one or two units to work in harmony i.e. when one unit is extracting the other is supplying which can improve further the ventilation in a room or home. Wiring diagram for 2 units, diagram 18G.
VERSIONS
“S1” “S2” Operation
O O OFF
I O Speed 1
O II Speed 2
I II Speed 3
S1 S2 S3
II
I
“S3” Operation
Heat recovery
(Alternate flow)
Free cooling
OPERATION
any type of combustion unit. It must expel air outside via its own special duct.
• Operating temperature: -20°C up to +50 °C.
• The device is designed to extract clean air only, i.e. without grease, soot, chemical or corrosive agents, or flammable or explosive mixtures.
• Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
• Do not immerse the device or its parts in water or other liquids.
• Turn off the main switch whenever a malfunction is detected or when cleaning.
• For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the wiring regulations, to provide a full disconnection under overvoltage category III conditions (contact opening distance equal to or greater than 3mm).
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
• Do not obstruct the fan or exhaust grille to ensure optimum air passage.
• Ensure adequate air return/discharge into/from the room in compliance with existing regulations in order to ensure proper device operation.
• If the environment in which the product is installed also houses a fuel-operating device (water heater, methane stove etc., that is not a “sealed chamber” type), it is essential to ensure adequate air intake, to ensure good combustion and proper equipment operation.
STANDARD
External grille in high quality, impact and UV-resistant ABS colour RAL 9010.
WARNING:
Ensure that the electric wiring to L and N is done correctly; an incorrect connection will lead to malfunction or permanent
damage of the fan.
Two or more units can operate at a fixed speed in a synchronised way (one unit extracts, the other supplies, and viceversa). Wiring diagrams: Fig 18 A-B-C. The initial starting air direction is achieved by setting the dedicated jumper (Fig. 20A-20B)
RESET OF THE SYNCHRONISATION
OPTION 1 If two or more units are connected under the same main switch or under a dedicated switch, to reset the synchronisation, the switch must be
SYNCHRONISATION IN CASE OF INSTALLATION WITHOUT CONTROLLER
Page 3
3
STANDARD CONFORMITY
2014/35/EU Low Voltage Directive (LVD) and 2014/30/EU Electromagnetic Compatibility (EMC), in conformity with the following standards: Electrical Safety EN60335-1(2008); EN 60335-2-80(2005); EN 60335-2-80/A2(2009) Electromagnetic Compatibility EN 55014-1(2006)+A1+A2; EN 55014-2(1997)+A1(2001)+A2(2008)+IS1(2007), EN 61000-3-2(2006)+A1(200
9)+A2(2009); EN 61000-3-3(2008).
Maintenance can be carried out by the user as indicated at page 14 Service must be perfmormed only by technically qualified personnel in accordance with local rules and regulations. Make sure that the mains supply to the unit is disconnected (page 15). Cleaning of the heat exchanger can be performed from outside as well.
MAINTENANCE AND SERVICE
Integral jumper set in position A (Fig.20A) means “extract” mode. Intergal jumper set in position B (Fig.20B) means “intake” mode. The jumper position defines both the air-flow direction when the unit is activated for the first time (for the synchronisation) and the air-flow direction of the free-cooling mode.
JUMPER POSITION
If two or more units are controlled by means of the same controller (149-SEN-CTRLS or similar), they always operate in a synchronised way. Wiring diagram as per Fig. 18.
SYNCHRONISATION IN CASE OF INSTALLATION WITH CONTROLLER
switched first OFF and then ON to reactivate (fig.31) OPTION 2 If two or more units are not connected under the same main switch, to reset the synchronisation, press at the same time the black pin of each unit (fig.33) at least 3 seconds.
DIMENSIONS
164
q
A
27510
164
q
108
O
mm
164
q
C
D
External grille
164
q
B
Mori HR 100 Mori HR 150
A
164 218 B 46 51 C
164 218 D 270÷510 300÷560 E Ø 108 158
Page 4
4
INSTALLATION
1
CONTENUTO IMBALLO MODELLO MORI HR
Mori HR 100 - Mori HR 150
4
3
5
min. 108mm HR100 min. 158mm HR150
INDOOR
OUTDOOR
1° ÷ 2°
2
insulation foam
6
7
=Ø 5x40mm
=Ø 8x10mm
Page 5
5
8 9
10
11
100mm HR100 115mm HR150
12 13
14 15
Page 6
6
16
17
18C
SPEED 1 (FIXED)
SPEED 2 (FIXED)
SPEED 3 (FIXED)
S3 S2 S1 GND
N L
CTRL-S
S1 S2 S3
II
I
N
L
OK
1 1 1
S3 S2 S1
18F
18A
18B
SPEED 1 to 3
SPEED 2 to 3
18D
18E
Page 7
7
19
S3 S2 S1 GND
N L
S1 S2 S3
II
I
N
L
OK
S3 S2 S1 GND
N L
CTRL-S
1 1 1
S3 S2 S1
18G
UNIT 1
UNIT 2
S3 S2 S1 GND
N L
CTRL-S
S1 S2 S3
II
I
N
L
OK
1 1 1
S3 S2 S1
18F
JUMPER POSITION A
20A
EXTRACT
21
JUMPER POSITION B
20B
INTAKE
22
Page 8
8
23
CLICK
24
25
27
26
Page 9
9
Ø 5x40mm
3-5mm
EXTERNAL GRILLE FOR Mori HR
29
28
30
31
32
TO RESET OF THE SYNCHRONIZATION OF THE UNITS (OPTION 2)
33
TO RESET OF THE SYNCHRONIZATION OF THE UNITS (OPTION 1)
Page 10
10
34
35
36 37
38
I
39
40
41
I
FILTER CLEANING (MAINTENANCE)
Can be carried out by the user
Page 11
11
71
48
49
44
45
46
42
43
47
HEAT EXCHANGER CLEANING (SERVICE)
Must be carried out only by technically qualified personnel
Page 12
12
71
52
56
50
53
51
100mm HR100 115mm HR150
54
55
Fig. 57 149-SEN-CTRLS
I
I I
REMOTE CONTROLLER (on request) HIGHLY RECOMMENDED
Page 13
13
a) Mark - ELTA FANS ELTA FANS
b) Model - MORI HR 100 MORI HR 150
c) SEC class - A A
c1) SEC warm climates kWh/m2.a -15,6 -16,2
c2) SEC average climates kWh/m2.a -37,5 -38,2
c3) SEC cold climates kWh/m2.a -75,6 -76,4
Energy label - Yes Yes
d) Unit typology - Residenal - bidireconal Residenal - bidireconal
e) Type of drive - Mul-speed drive Mul-speed drive
f) Type of Heat Recovery System - Heat recovery Heat recovery
g) Thermal eciency of heat recovery % 74 74
h) Maximum ow rate m3/h 25 60
i) Electric power input at maximum ow rate W 2,6 3,8
j) Sound power level (LWA) dBA 35 38
k) Reference ow rate m3/h 17 41
l) Reference pressure dierence Pa 10 10
m) Specic power input (SPI) W/m3/h 0,071 0,054
n1) Control factor - 1 1
n2) Control typology - Manual control (no DCV) Manual control (no DCV)
o1) Maximum internal leakage rate % N/A N/A
o2) Maximum external leakage rate % 1% 1%
p1) Internal mixing rate % N/A N/A
p2) External mixing rate % N/A N/A
q) Visual lter warning - N/A N/A
r) Instrucons to install regulated grilles - N/A N/A
s) Internet address for preassembly/disassembly instrucons - www.eltafans.com www.eltafans.com
t) Airow sensivity to pressure variaons % N/A N/A
u) Indoor/outdoor air ghtness m3/h 21 60
v1) AEC - Annual electricity consumpon - warm climates kWh 1 0,7
v2) AEC - Annual electricity consumpon - average climates kWh 1 0,7
v3) AEC - Annual electricity consumpon - cold climates kWh 1 0,7
w1) AHS - Annual heang saved - warm climates kWh 18 18,1
w2) AHS - Annual heang saved - average climates kWh 39,9 40
w3) AHS - Annual heang saved - cold climates kWh 78 78,2
ErP Directive - Regulations 1253/2014 1254/2014
Page 14
14
Information on disposal of units at the end of life. This product complies with EU Directive 2002/96/EC. The symbol of the crossed-out dustbin indicates that this product must be collected separately from other waste at the end of its life. The user must, therefore, dispose of the product in question at suitable electronic and electro-technical waste disposal collection centres, or else send the product back to the retailer when purchasing a new, equivalent type device. Separate collection of decommissioned equipment for recycling, treatment and environmentally compatible disposal helps to prevent negative effects on the environment and on health and promotes the recycling of the materials that make up the equipment. Improper disposal of the product by the user may result in administrative sanctions as provided by law.
DISPOSAL AND RECYCLING
GUARANTEE
The product is offered with a five year warranty.
First year of warranty covers parts and labour, following this period the warranty covers replacement parts only based on maintenance having being carried out in accordance with our literature and terms and conditions of sale. Proof of Purchase, Periodic inspection and maintenance will be required in the event of any warranty claim.