Elsys ERS, ERS-lite, ERS-CO2, ERS-Sound Operating Manual

OPERATING MANUAL ERS
OPERATING MANUAL
Elsys Room Sensor. ERS, ERS-lite, ERS-CO
2,
ERS-Sound
Description ........................... 2
Installation ............................ 3
Sensor configuration ............ 5
Sensor application ................ 8
Motion detector ................... 11
Specification ........................ 13
Regulations ......................... 14
OPERATING MANUAL ERS
www.elsys.se 2
support@elsys.se
Description
Elsys room sensor (ERS) is a universal indoor climate sensor for LoRaWAN™ wireless network. The sensor measures temperature, humidity, light intensity*, Co2*, sound level and detects motion*. Elsys room sensor is a battery powered
device and designed to be instal led qu ickly and easily. The motion sensor can be used for presence monitoring systems. All Elsys sensors are equipped with NFC (Near Field
Communication) and can be easily configured from a smartphone.
Main features of Elsys Room Sensor
Compatible with LoRaWAN™ specification
Measures ambient temperature
Measures ambient humidity
Measures ambient Co2
Measures light intensity
Detects motion using a passive IR sensor
Measures sound level
Easy installation
Easy configuration
May be installed on wall or any surfac e
Battery powered
Long range
Configurable over NFC
Configurable over the air
10 years batty life**
Supports US902-928, EU863-870, AS923, AU915-
928, KR920-923
* Depends on ERS model (ERS-light, ERS, ERS-Co2, ERS-Sound). ** Depending on interval
OPERATING MANUAL ERS
www.elsys.se 3
support@elsys.se
Installation
1. Remove the back panel of the sensor with a small screwdriver.
2. Install the batteries. The ERS requires one or two AA batteries. The battery type is 3.6V Lithium Battery (ER14505). You can use one battery. For the ERS­CO
2
and ERS-Sound we recommend two batteries to get maximum operation time. Use battery slot A if only one battery is used.
OPERATING MANUAL ERS
www.elsys.se 4
support@elsys.se
3. Mount the pack panel on the wall using some of the six mounting holes.
4. Attach the sensor part to the back panel.
I
CAUTION
Using batteries other than specified may result in explosion. Dispose of properly, observ ing environmental protection rules.
OPERATING MANUAL ERS
www.elsys.se 5
support@elsys.se
Sensor configuration
All sensor settings can be configured via smartphone and Android application with NFC (Near field communication) or over the air via the network server and downlink data to the sensor. Sampling rate, spreading factor, encryption keys, port and modes can be changed. All sensor settings can be locked from the server or NFC and end users cannot read or change settings on the sensor.
Android application
1. Download Elsys “Sensor Settings” application from Google Play Store and install it on an Android smartphone or tablet. The device must support NFC.
2. Enable NFC on the device and start the application.
3. Place your Android device on top of the NFC antenna on the sensor.
4. Remove the Android device from the sensor when the data has been updated.
5. See the help in the application for more information
OPERATING MANUAL ERS
www.elsys.se 6
support@elsys.se
Sensor settings parameter’s
SplPer
The main time base for the
sensor. This is the interval for the sensor to wake up
and sample data.
PirCfg
Configuration for the motion
detector. Off: PIR sensor is off
Trigger: Sensor sends
package on motion Count: Sensor counts motions events between two
transmissions
TempPer
Temperature sample period.
Value * Timebase= Sample time. Most of the time its easiest to use 1 as period
and only change time base
PirPer
Value * Timebase= PIR sample time.
SendPer
Value * Timebase= Send time.
VddPer
Value * Timebase= Voltage sample time.
LightPer
Value * Timebase= Light sample time.
AppEui
Application ID (8bytes or 16 hex digits)
AppKey
Application unique key (16bytes or 32hex digits)
Ota
Join mode, “over the air
activation” or “personalization”. Valu e:tr u e
or false
DevEui
Unique ID of the sensor
(8bytes or 16 hex digits)
AppSKey
Application session key.
OPERATING MANUAL ERS
www.elsys.se 7
support@elsys.se
Application unique session
key(16bytes or 32hex digits) (this is onl y valid if not
using OTA)
NwkSKey
Network session key.
Network unique session key(16bytes or 32hex digits) (this is onl y valid if not
using OTA)
DrDef
Default data rate for the sensor. DR0–>DR5
DrMax
Minimum data rate for the sensor. DR0–>DR5.
DrMin
Maximum data rate for the
sensor. DR0–>DR (If datarate min, max, def is the same then server can’t
change sensor data rate)
Port
LoRa communication port
Co2Cfg
Calibrate CO2 sensor if
parameter is 1. The sensor
must be in fresh air (outside)
Lock
Locks or unlocks sensor
settings. 0 = unlocked, anything else will lock the sensor until the same code is
entered again
Plan
Active cha nn el pla n
Plans
Supported channel plans(read-only)
Subband
Channel plan subband
(hybrid modes) 0 = 0-7, 1 =
8-15, etc.
Qsize
Sample queue size 0-10
Qoffset
Include offset bytes (0,1)
Qpurge
Purge sent samples from queue (0,1)
OPERATING MANUAL ERS
www.elsys.se 8
support@elsys.se
Sensor application
Sensor startup
When the sensor starts up it loads configuration from the internal memory and merge it with user configuration. When the configuration is done the sensor writes the new configuration to the NFC chip. The sensor always writes new
configurations to the NFC chip when something changes in the sensor or if NFC data is corrupted by a NFC writer or phone. The sensor always writes new configuration to NFC chip at startup. When configuration is done the sensor tries to join the network if OTAA (Over The Air Activation) is enabled. The sensor led flashes orange when it tries to join a network. The sensor tries to join the network every 10 second and increases the join timer at every failed attempt by 10%, up to maximum 1 hour. After startup, configuration and join the sensor enters sampling mode.
OPERATING MANUAL ERS
www.elsys.se 9
support@elsys.se
NFC read/write
When reading or writing NFC configuration data to the sensor it starts a timer and delays its action x seconds. It delays its action because of the bad connection that can be in NFC communication. Types of bad connection can be distance, location or rapid movement. After the delay the sensor determines if the NFC data has changed or not. If the data has change the sensor reboots and starts from power up. When writing data to the sensor try to get the best connectivity as possibly. Locate the NFC antenna of the phone and sensor. Keep the 2 devices as close as possible and don’t move them while writing or reading. When you have written data to the sensor, let the sensor reboot and restart before trying to write again. You can al wa ys valid ate your settings by reading the NFC data after the sensor has restarted.
OPERATING MANUAL ERS
www.elsys.se 10
support@elsys.se
Sampling mode
OPERATING MANUAL ERS
www.elsys.se 11
support@elsys.se
Motion detector
Detection range
Detection range of the Motion Sensor is shown below. Actual range of the sensor can be influenced by environmental conditions. Avoid insta ll ing t he sensor in ar eas wh ere i t will face direct or reflected sunlight. Avoid installing near windows, air conditioning or heating vents.
OPERATING MANUAL ERS
www.elsys.se 12
support@elsys.se
Detection pattern
Detection pattern of the motion sensor is shown below.
OPERATING MANUAL ERS
www.elsys.se 13
support@elsys.se
Specification
Power supply:
3.6V DC
Battery type:
AA 14505
EU directives compliance:
Radio protocol:
LoRaWAN™
Radio frequency band:
US902-928, EU86 3-870,
AS923, AU915-9 28, KR 920 -
923
Range:
8km
(SF10 868Mhz,depending on terrain and building
structure)
Recommended installation height:
1.6M Operating temperature
0-40°C
Temperature range
0-40°C
Temperature resolution
0.1°C
Temperature accuracy
± 0.5°C
Humidity range
0-100%
Humidity resolution
0.1%rh
Humidity accuracy
±2%rh
CO2 range
0 - 2000ppm
CO2 noise
14 ppm @ 400 ppm 25 ppm @ 1000 ppm
CO2 accuracy
±50ppm ±3% of reading
Light range
4-2000 Lux
Light resolution
1 Lux
Light accuracy
±10 Lux
Sound range, mean value
35-70 dBspl
Sound range, peak value
65-99 dBspl
Sound resolution
1 dB
Sound accuracy
+- 5 dB
Dimensions
86x86x28mm
Battery lif e
Up to 10 years (depends on settings)
OPERATING MANUAL ERS
www.elsys.se 14
support@elsys.se
Regulations
Legal Notices
All information, including, but not limited to, information regarding the features, functionality, and/or other product specification are subject to change without notice. Elsys reserves all rights to revise or update its products, software, or documentation without any obligation to notify any individual or entity. Elsys and Elsys logo are trademarks of Elektroniksystem I Umeå AB. All other brands and product names referred to herein are trademarks of their respective holders.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energ y and , if not installed and used in accordance with the instructions, may cause harm ful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
-- Reorient or relocate the receiving antenna.
OPERATING MANUAL ERS
www.elsys.se 15
support@elsys.se
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced ra di o/T V techn ic ian for help.
Non-modifications Statement:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
Caution
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance with FCC multi-transmitter product procedures.
Industry Canada Statement
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and
OPERATING MANUAL ERS
www.elsys.se 16
support@elsys.se
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Declaration of conformity
Hereby, Elektroniksystem I Umeå AB declares that Elsys Room Sensor is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.
V3 2018-04-10
Loading...