Elster Solutions HHI01 User Manual

Rhein Tech Laboratories, Inc. Report #: 2004234 360 Herndon Parkway FCC ID: G8JHHI 01 Suite 1400 Model #: 52808G505 Herndon, VA 20170 Standard: FCC Part 90 http://www.rheintech.com Date: January 24, 2005
APPENDIX K: USER’S MANUAL
Please refer to the Operator’s Manual.
. Page 37 of 41
E
E
E
D
D
D
I
I
I
U
U
U
G
G
G
R
R
R
E
E
E
S
S
S
U
U
U
Copyright © 2004 AMCO Automated Systems All Rights reserved Rev A
ntt
IIn
((T
Wii
W
TRACE®
Trr
T
errrr
e
V
V
TII
n
d
n
d
D
D
R
R
a
c
a
c
o
g
o
g
R
R
V
V
orr
ffo
o
o
T
T
R
R
w
w
A
A
F
F
e
e
att
a
T))
T
s
s
C
T
T
orr
o
C
E
E
TRACE INTERROGATOR VRT (CE) OPERATIONS
Introduction ...................................................... 4
System Requirements ..................................... 5
Hardware Requirements........................................................... 5
Software Requirements ............................................................ 5
Warnings.................................................................................... 5
TI VRT CE Operation................................................................. 5
Conventions ..................................................... 5
<Esc> ......................................................................................... 6
<Enter>....................................................................................... 6
<Up Arrow>, <Down Arrow>.................................................... 6
<Tab> ......................................................................................... 6
Message Box <Yes> <NO> ....................................................... 6
TIV Screens ......................................................7
Login .......................................................................................... 7
Main (D)...................................................................................... 7
Route Selection (D) ................................................................... 7
Communications (D) ................................................................. 8
Data Entry.................................................................................. 8
Exit TI VRT CE ........................................................................... 8
Account Navigation and Data Entry............... 9
Navigation.................................................................................. 9
<Esc>..............................................................................................9
<Enter> .........................................................................................10
<Up Arrow>, <Down Arrow>......................................................10
Jumps ...................................................................................... 10
Jump to the Previous Route.......................................................10
Jump to Beginning of Current Route.........................................10
Jump to End of Current Route ...................................................10
Jump to Next Unread Interrogation ...........................................10
Jump to Specified Sequence Number .......................................11
Jump to Next Unread Account in the Current Route................11
Jump to Next Route.....................................................................11
Trace Interrogator VRT (CE) - User Guide
AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004
TRACE INTERROGATOR VRT (CE) OPERATIONS
Searches.................................................................................. 11
Information Displays............................................................... 12
Help / Available Commands Display..........................................12
Route Selection Display..............................................................12
Route Summary Display .............................................................13
Configuration Display .................................................................13
Display VRT Requests Details....................................................13
Trouble Code Display..................................................................14
Messages Display........................................................................15
Error Log Display ........................................................................15
Data Entry operations............................................................. 16
Manual Index Read......................................................................16
Clear Index Read .........................................................................17
Force Unattempted Account ......................................................17
Adding a Trouble Code ...............................................................17
Adding / Editing a Text Message................................................18
Setting the Re-sequence Flag ....................................................19
Single RF Index Read..................................................................20
Multiple Parameter RF Read.......................................................21
Single History / TOU RF Read ....................................................22
General Index RF Read ...............................................................22
TI VRT CE Communication with Route
Manager VRT .................................................. 23
Establishing communications................................................ 23
Uploading Routes from RM VRT to TI VRT(CE) .................... 25
Downloading data From TI VRT(CE) to RM VRT ................... 26
Removing Route From TI VRT (CE) ....................................... 26
Updating Handheld files ......................................................... 26
Hot keys .......................................................... 28
Troubleshooting............................................. 29
Trace Interrogator VRT (CE) - User Guide
AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004
TRACE INTERROGATOR VRT (CE) OPERATIONS
Introduction
Copyright © 2004 AMCO Automated Systems. All Rights Reserved
The contents of this document are the property of AMCO Automated Systems and are copyrighted. All rights reserved. Any reproduction, in whole or in part, is strictly prohibited. For additional copies of this document, please contact:
Customer Service AMCO Automated Systems 107 Erskine Lane Scott Depot, WV 25560 Phone: 304-757-3300 Fax: 304-757-3388 http://www.amcoas.com
The information contained herein has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. AMCO Automated Systems reserves the right to make changes without prior notice. This document is not covered by any warranty either expressed or implied. Any correction, comments or additions to the contents of this document should be directed to AMCO Automated Systems at the above address.
TRACE, Universal RF Interface (RF), Mini Mobile Interrogator (MMI) and ReadIt are also trademarks of AMCO Automated Systems. All rights reserved.
MS-DOS, MS Windows, MS Windows CE and IBM are registered trademarks of their respective owners.
FCC Compliance
The VRT HAND HELD Interrogator (HHI) has been type accepted by the Federal Communications Commission under Part 90. Transmitter licensing is required by the FCC. The VRT HAND HELD Interrogator (HHI) transmitter is currently licensed by the FCC to operate at 450-460 MHz. FCC ID is G8JHHI01.
Changes or modifications to this equipment not expressly approved by AMCO Automated Systems could void the user's authority to operate this equipment.
This device complies with Part 15 of the FCC rules. Operation is subject to the condition that this device does not cause harmful interference.
The TRACE transponder is governed by FCC Part 15 and requires no licensing.
Trace Interrogator VRT (CE) - User Guide
AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004
TRACE INTERROGATOR VRT (CE) OPERATIONS
System Requirements
Hardware Requirements
DAP 5240 or 5240X with AMCOAS HHI RF card Radix FW-500 with AMCOAS HHI RF card
Software Requirements
Windows CE 3.0 or later Route Manager VRT
Warnings
Do not attempt to modify or edit any of the subsidiary tables or files outside of the TI VRT (CE) / RM VRT environment without prior authorization by AMCO Automated Systems technical service personnel. Unauthorized manipulation of these files may void your software service agreements.
Uploading from Route Manager VRT (RM VRT) will overwrite Route/Account information on the Hand Held. It is the User’s responsibility to download any data prior to uploading.
RF EXPOSURE
The antenna used for this transmitter must be installed to provide a separation distance of at least 24 cm from all persons, and must not be co-located or operating in conjunction with any other antenna or transmitter.
TI VRT CE Operation
TI VRT for CE is supported on two different hardware platforms: the DAP 5240 and the Radix FW-500. While most operations are identical some are platform specific. Features for the DAP 5240 are marked D and those for Radix are marked R.
The screen shots shown in various illustrations may vary slightly from your Handheld’s display.
Conventions
All user interactions are via the Handheld’s keyboard. TI VRT CE responds to the keystrokes independent of platform. All letters are assumed to be upper case. Function keys F1 – F4 are also used.
Trace Interrogator VRT (CE) - User Guide
AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004
TRACE INTERROGATOR VRT (CE) OPERATIONS
<Esc>
o Cancels operations o Exits screens
<Enter>
o In menus/list boxes selects item o In editable field submits entry o With Automove on, submits entry and moves to next Account. o In Details list box (History & TOU) initiates single interrogation of
highlighted item
<Up Arrow>, <Down Arrow>
These keys are used to navigate between accounts within the current Route. When either the first or last account is reached an audible warning will sound and the display will remain on the current account.
<Tab>
 key is used to navigate between fields within the current screen (messages, search, etc.).
Message Box <Yes> <NO>
The response to the message box can be:
o Touching the button <Yes> or <No> o Clicking letter “Y” or “N” on the keyboard o Moving to the desired button by using left/right arrow keys and
pressing Enter when the button is highlighted.
D at the bottom (in Lower right corner) of the data entry screen indicates VRT request details are available. The number after the D indicates the number of requests.
AM-off/on at the bottom (in Lower right corner) of the data entry screen indicates AutoMove is enabled or disabled.
M at the bottom (in Lower right corner) of the data entry screen indicates messages are available.
Trace Interrogator VRT (CE) - User Guide
AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004
TRACE INTERROGATOR VRT (CE) OPERATIONS
TIV Screens
Login
The Login screen is not currently operational.
Main (D)
The main screen allows the selection of the following modes:
o Route Selection / Data Entry o Communication (between RMVRT and device)
Route Selection (D)
If Route Selection is selected, the list of routes loaded in the device is displayed. To view/update Account information for the chosen route highlight the route and press “Enter”.
Trace Interrogator VRT (CE) - User Guide
AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004
TRACE INTERROGATOR VRT (CE) OPERATIONS
Communications (D)
The Communications mode is used to exchange data files and other information with Route Manager VRT. This selection, opens the specified communications port, displays the communications screen and initiates polling for incoming messages from RM VRT.
Data Entry
Rt: Route ID Sq: Sequence Number Ad: Address Nm: Customer Name Xp: Transponder Mn: Meter Number Ac: Account Number TT: Transponder Type MT: Meter Type PC: Premise Code SV: Survey Code LC: Location Code IC: Instruction Code RD: Index Read TC: Trouble Code ST: Account Status Æ : Direction of Data Entry
D VRT Details available
AM-off/on AutoMove enabled M Messages available
Exit TI VRT CE
Pressing the <ESC> in the Main Menu will pop up a confirmation box. Use the <TAB>, <Left Arrow>, or <Right Arrow> keys to select the response.
Press “YES” button or click the “Y” key or click the <Enter> key when the button is highlighted to accept the selection.
Press <No> button or click the “N” key or click the <Enter> key when the button is highlighted to Cancel.
Trace Interrogator VRT (CE) - User Guide
AMCO Automated Systems P/N 52808T510 Rev. A, December 15, 2004
Loading...
+ 21 hidden pages