June 2011 IL42-5016D
EA_Water 2.0 module
Installation instructions
This leaflet contains instructions for Elster’s EA_Water 2.0 module for use on water meters to provide readings to the EnergyAxis
®
System. For proper installation and maximum life of the modules, use the following procedures.
The EA_Water 2.0 module can be installed as an integral, wall, or pipe mount. The integral mount consists of the module being mounted directly to the water meter. See “Integral mount” on page 1 for specific instructions. The wall mount is mounted to a mostly flat surface such as a wall or other surface. See “Wall mount” on page 2 for specific instructions. The pipe mount consists of hardware to mount the module to a pipe. See “Pipe mount” on page 4 for specific instructions.
Familiarize yourself with the location and identification of the terminals on your water meter registers before any installation procedure.
Radio communications performance and mounting
The EA_Water 2.0 module is designed to provide excellent radio communications performance when it is mounted such that the front surface arrows point up. Alternate mounting orientations may impair radio communications performance.
Connection instructions
The EA_Water 2.0 module register connections are as follows:
Function
Data Green Red Green Green Green Red
Power (or power/clock) Red Green Red Red Red Black
Common (ground) Black Black Black Black Black Green
Module
cable color
Elster AMCO Badger Sensus Hersey Neptune
Register terminal color
Installation instructions
Integral mount
The EA_Water 2.0 module is shipped fully assembled and ready to install. You will need to mount the EA_Water 2.0 module directly onto the water meter register. The integral mount cover has a hoop that fits around the water meter register.
Elster
Raleigh, North Carolina USA +1 800 338 5251 (US toll free) +1 905 634 4895 (Canada) support@us.elster.com
IL42-5016D June 2011
CAUTION
!
EA_Water 2.0 remote module
Integral mount cover
1. Align the hoop EA_Water 2.0 module over the water meter register so that the EA_Water 2.0 module wires are able to connect to the water meter terminals.
2. Securely attach the EA_Water 2.0 module over the water meter register.
3. Using the table in “Connection instructions” on page 1, connect the appropriate wires to the correct terminals on the water meter register. Typically, the connection is made by placing the wire under the screw terminal and tightening down securely. See the product documentation for your water meter register for more information.
Wall mount
The EA_Water 2.0 module can be mounted on a wall close to the water meter. To assist placing the enclosure on the hanging screw, the enclosure has hash marks that will help you properly align the module.
The cable from the EA_Water 2.0 module and the water meter register should not exceed 100 feet (30 meters).
1. Remove the remote mount cover from the EA_Water 2.0 module.
Be sure to connect the cables correctly. Failing to properly connect the cables may prevent the module from operating correctly. For information on proper connections, see “Connection instructions” on page 1.
2. For proper operation of the module, connect the cables as described in “Connection instructions” on page 1. a. If you do not have an inline connector, splice the cables from the EA_Water 2.0 module to the water meter
register cable using weatherproof gel caps (for example, 3M style 314 IDC). Be sure to follow the manufacturer’s directions for wire preparation when using gel caps.
2
June 2011 IL42-5016D
CAUTION
!
Cable tie
Be sure to carefully
align arrows
Insert the cable back into the EA_Water 2.0 module, making sure to provide strain relief for the cable. Be sure to securely fashion the cable by using the cable tie, as illustrated in the next figure.
Be sure that the arrows are as closely aligned as possible before mating. Failing to properly align the arrows may result in damage to the connector, requiring a replacement of either the connector or the module itself.
b. If you have an inline connector, align the arrows on both connector ends. Press firmly to fully mate the
connectors (see next figure).
3. Reattach the remote mount cover to the EA_Water 2.0 module.
4. Hang the EA_Water 2.0 module on the hanger screw, making sure it is level.
5. Screw 2 screws into the 2 bottom supporting screw mounts.