Operating instructions
www.docuthek.com
Diaphragm gas meters BK-G.6 to BK-G5
Translation from the German
© 2013 Elster GmbH

Contents

Contents
Diaphragm gas meters BK-G.6 to BK-G5 .
Contents ..............................
Safety.................................
Checking the usage .....................
Diaphragm gas meters BK-G1.6 to G25 ......2
BK with integrated “Smart Valve”............2
Type code .............................2
Part designations ........................2
Type label/Index plate.....................2
ATEX identification .......................3
Installation ............................
Temperature test point ..................4
Connecting the pressure measuring line ...4
Tightness test ..........................5
Commissioning.........................5
BK-G..M with mechanical index.............5
BK-G..A with Absolute ENCODER indexAE1/Z6 5 BK-G..A with Absolute ENCODERAE2/AE3
and communications moduleACM ..........5
BK-G..E, BK-G..ETB, BK-G..B with electronic
index .................................5
Diaphragm gas meters BK with integrated valve 5
Maintenance/Removal...................6
Accessories ...........................6
Technical data .........................7
Declaration of conformity ................7
ATEX legend ...........................9
Contact ..............................0

Safety

Safety
Please read and keep in a safe place
carefully before installing or operating. Following the installation, pass the instructions on to the opera- tor. This unit must be installed and commissioned in accordance with the regulations and standards in force. These instructions can also be found at www.docuthek.com.
Explanation of symbols
, , , ... = Action
= Instruction
Liability
We will not be held liable for damage resulting from non-observance of the instructions and non-com- pliant use.
Safety instructions
Information that is relevant for safety is indicated in the instructions as follows:
Please read through these instructions
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified gas technicians. Electrical interventions may only be carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM spare parts.
Transport
Diaphragm gas meters are always to be transported in the upright position. On receipt of the product, check that the delivery is complete (see Part desig- nations). Report any transport damage immediately.
Storage
Diaphragm gas meters are always to be stored in the upright position and in a dry place. Ambient tempera- ture: see Technical data.
Changes to edition 05.
The following chapters have been changed: Checking the usage – Commissioning – Maintenance/Removal – Accessories Technical data Declaration of conformity
GB
GB-1
F
NL
I
SK

Checking the usage

m
3
,
-
BK-G..M..
12345678
DE-07-MI002-PTB001 class 1,5
NG-47001BM0443 DIN EN 1359:2007
Q
max
Q
min
002545632734 1 imp =^ 0,01 m
3
M12 0102
Diaphragm gas meters BK-G.6 to G5
Residential or commercial diaphragm gas meters BK for recording gas consumption values for natural gas, town gas, propane and butane, as gases of the first to third families pursuant to DIN EN 437:2003 (DVGW Code of Practice G260). If used for internal measurements which are not subject to statutory testing, the gas meter is also suitable for hydrogen, nitrogen, air and inert gases.

BK with integrated “Smart Valve”

Not suitable for highly contaminated gases, e.g. town gas.
GB
Potentially explosive atmosphere
Diaphragm gas meters that are labelled with and (see sticker near the index) are suitable for
operation in potentially explosive atmospheres, see page7 (Declaration of conformity).
The meter function is only guaranteed when used
under the specified operating conditions– see page 7 (Technical data). Any other use is con- sidered as non-compliant.

Type code

Code Description
BK-G Diaphragm gas meter
.6
.5 4
6 0 6
5
M
C
A
E
B
T
Te
TB
Chekker mechanical index Absolute ENCODER index
Indication of volume at base conditions
Temperature conversion:
mechanical-electronic temperature
conversion and pressure correction
Flow rate
0.016 – 2.5 m
0.025 – 4 m
0.04 – 6 m3/h
0.06 – 10 m
0.1 – 16 m3/h
0.16 – 25 m
0.25 – 40 m
3 3
3
3 3
Mechanical index
Electronic index
mechanical
electronic

Part designations

6
5
4
3
1
Diaphragm gas meter BK
Index with index plate Connectors
4 Protective caps
5 2 x thermowells (optional) 6 Pressure test point with sealing sleeve (optional)

Type label/Index plate

Diaphragm gas meters BK-G..M..
BK-G..M..
DE-07-MI002-PTB001
Q
max
Q
min
M12 0102
002545632734 1 imp =^ 0,01 m
class 1,5
12345678
NG-47001BM0443 DIN EN 1359:2007
,
3
-
Diaphragm gas meters BK-G..A.. with
Absolute ENCODER index
/h /h
/h
/h
Diaphragm gas meters BK-G..E
/h
BK-G..A..
ENCODER VALVE Vs
M12 0102
DE-07-MI002-PTB001
002545632734
Q
max
Q
min
M12 0102
002545632734
,
NG-47001BM0443 DIN EN 1359:2007
class 1,5
BK-G..E..
DE-07-MI002-PTB001
class 1,5
-
12345678
Diaphragm gas meters BK-G..E themis
BK-..E
t
Q
max
m
t
Q
min
V p
max
class 1,5
M13 0102
002519280846 2013
g
12345678
2
3
m
3
m
log
Diaphragm gas meters BK-G..B
BK-..B
Q
max
Q
min
class 1,5
M12 0102
002545632734
12345678
Vb
GB-2
F
NL
I
SK
BK-G..E and BK-G..B
BK-G..
m
3
The following data is not specified on the type label/
index plate, but can be called up in the menu:
specified centre temperaturet
temperature conversion only), EN 1359 registration number (if available), firmware version.
Diaphragm gas meters with integrated valve
(for meters with
sp
VALVE Vx
Diaphragm gas meters BK-G..B
Elster GmbH, Strotheweg 1
BK
D-49504 Lotte, Germany
II -/2 G IIA T4
TÜV 12 ATEX 098560 X
Use as follows: Category: internal: none, external: Category2 (Zone1).
Type of atmosphere: gases, hazes and vapours.
Valve variants: Vs = Smart Valve Vp = bi-stable valve (prepayment meter) Ve = bi-stable valve for electronic index
Up to 12.2011, all valve versions were simply marked with the word VALVE on the type label/
index plate.
ATEX identification BK-G..M, BK-G..C, BK-G..MT, BK-G..CT
Elster GmbH, Strotheweg 1
BK
D-49504 Lotte, Germany
II -/2 G c IIB TX
TÜV 11 ATEX 090370 X
Use as follows: Category: internal: none, external: Category 2 (Zone1).
Type of atmosphere: gases, hazes and vapours.
Diaphragm gas meters BK-G..A, BK-G..AT
Elster GmbH, Strotheweg 1
BK
D-49504 Lotte, Germany
II -/2 G IIB T4
Ui=5,5V Ii=30mA Pi=33mW Ci=140µF Li=0µF
Use as follows: Category: internal: none, external: Category2 (Zone1).
Type of atmosphere: gases, hazes and vapours.
Diaphragm gas meters BK-G..E, BK-G..ET, BK-G..ETB
Elster GmbH, Strotheweg 1
BK
D-49504 Lotte, Germany
II -/3 G IIA T1
TÜV 11 ATEX 093627 X
Use as follows: Category: internal: none, external: Category 3 (Zone2).
Type of atmosphere: gases, hazes and vapours.

Installation

WARNING
Please observe the following to ensure that neither persons nor the gas meter are damaged during installation and operation:
Note the max. allowable operating pres-
surep page2 (Type label/Index plate).
Note the permitted ambient temperaturetm and
gas temperaturetg, see page2 (Type label/ Index plate) or page7 (Technical data).
The gas meter is suitable for mechanical ambient
conditions of Class M1 of Directive 2004/22/EC. For gas meter versions BK..A, BK..E and BK..B,
ClassE2 for electromagnetic ambient conditions
also applies.
When installing the diaphragm gas meterBK
with integrated valve, make sure that no dirt
particles get into the meter and thus into the
valve.
The yellow sealing sleeve protects the pres-
sure test point on the gas meter. It may only be opened for connecting a pressure measuring line.
Use seals made from tested materials. Elastomer
seals or asbestos-free flat seals from Elster are recommended.
For meters resistant to high temperatures, only
use seals tested to be resistant to high tempera-
tures. Only use the seals once. For installation and operation, note the applica-
ble national regulations and the directives of the gas supply company. For Germany, the valid DVGW Code of Practice G600 (DVGW-TRGI) applies.
Work on meters and the installation of meters
which are marked with and are installed in
potentially explosive atmospheres may only be carried out by persons with appropriate qualifi- cations.
and measuring rangeQ
max
max
, see
GB
GB-3