MC : Controller for Double and Single Gates
Setup and Technical Information
Includes latest Intelligent Technology
Double & Single Gate Controller
with Eclipse Operating System (EOS)
6th Edition
Eclipse
®
MC
Page 2
All installations and testing must be done only after reading and understanding all instructions carefully. All wiring should be done only by trained technical personnel. Failing to follow instructions and the safety warnings may result in serious injury and/or damage to property.
Elsema Pty Ltd shall not be liable for any injury, damage, cost, expense or any claim whatsoever to any person or property which may result from improper use or installation of this product.
Risk in the goods purchased shall unless otherwise agreed in written pass to the buyer upon delivery of the goods.
Any figures or estimates given for performance of goods are based upon the company’s experience and is what the company obtains on tests. The company will not accept liability for failure to comply with the figures or estimates due to the nature of variable conditions affecting for example Radio Remote Controls.
Please keep this setup instruction for future reference.
Installed by: _______________________________________
Service date: ______________________________________
Important warning and safety instructions
2
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 3
Index
Features ..............................................................4
Description..........................................................4
Part Number ........................................................ 5
Menu Structure ............................................... 6-7
Connection Diagram ...........................................8
Setup Instructions ............................................... 9
Limit Switches...................................................10
Setup i-Learning Steps......................................11
Menu 1 – Auto Close ........................................ 12
- Normal Auto Close ................................... 12
- Auto Close with Photoelectric Trigger ......12
- Auto Close after an Open Obstruction ......12
- Auto Close after Power Restored...............13
- Normal Auto Close on
Sequential Obstructions ...........................13
- Auto Close Only when
Fully Opened ............................................ 13
- Auto Close Only at Night .......................... 13
Menu 2 – Pedestrian Access Features ........ 13-14
Menu 3 – Input Functions ................................. 14
Menu 4 – Photoelectric Beam ........................... 15
Menu 5 – Relay Output Functions ..................... 16
- Lock/Brake Output .................................... 17
- Courtesy Light .......................................... 17
- Service Call Output ..................................18
- Strobe or Warning Light ...........................18
Menu 6.1 – Lock/Brake Output Modes..............19
- Open Lock/Brake Activation .....................19
- Close Lock/Brake Activation ..................... 19
- Open Pre-Lock/Brake Activation ............... 19
- Close Pre-Lock/Brake Activation .............. 19
Menu 6.2 – Courtesy Light Output Mode .......... 20
Menu 6.3 – Strobe (Warning)
Light Output Mode ......................... 20
- Pre-Open Strobe Light Activation ............. 20
- Pre-Close Strobe Light Activation ............20
Menu 6.4 – Service Call Output Mode .............. 21
Menu 7 – Special Features................................22
- Remote Control Open Only ....................... 22
- Holiday Mode ........................................... 22
- Energy Saving Mode ................................22
- Automatic Stop / Open on Closing ........... 23
- Receiver Channel 2 Options .....................23
- Press and Hold on Open & Close Inputs .. 23
- Window and Louvre Mode .......................23
Menu 8 – Leaf Delay ......................................... 23
- Open Leaf Delay .......................................23
- Close Leaf Delay ......................................23
- Close Leaf Delay on Mid Open ................. 23
Menu 9 – Motor 1 Obstruction
Detect Margins..................................24
- Margin Example .......................................24
Menu 10 – Motor 2 Obstruction
Detect Margins................................25
- Margin Example .......................................25
Menu 11 – Motor Speed, Slow Speed
Area and Reverse Time ....................26
- Open and Close Speed ............................. 26
- Slow Speed ..............................................26
- Slow Speed Area ......................................26
- Obstruction Stop Reverse Delay Time ......26
Menu 12 – Anti-Jam, Electronic Braking and
Open/Close Obstruction Operation .27
Menu 13 – i-Learning ....................................... 28
Menu 14 – Password ........................................ 28
Menu 15 – Operational Records........................28
- Event History ............................................ 28
- Displays Gates/Doors Operations
and Current Levels ...................................28
Menu 16 – Tools ............................................... 29
- Number of Motors .................................... 29
- Set the Supply Voltage .............................29
- Resets Controller & Test Inputs ................ 29
- Travel Timer for Slip Clutch Motors..........29
- Solar Mode and Fuse Type ....................... 29
- Day and Night Sensitivity Adjustment ......29
- Slow Speed Ramp Down Time .................29
Accessories ....................................................... 30
- Battery Charger and Solar Applications .... 30
- Backup Batteries ....................................... 30
- Keyring Remotes & Photoelectric Beams .31
- Strobe Lights ............................................ 31
3
www.elsema.com
Page 4
Description
Features
Suitable for swing and sliding gates Double or single motor operation Eclipse Operating System (EOS) Day and night sensor (DNS) 24 or 12 Volt DC motor operation Motor soft start and soft stop Speed and force adjustment Large 4-line LCD to indicate controllers status
and setup instructions
1-Touch control for easy setup Auto profiling using latest intelligent
technology
Various inputs, push button, open only, close
only, stop, pedestrian and photoelectric beam
Supports limit switch inputs or mechanical
stops
Adjustable auto close, obstruction load and
pedestrian access
Adjustable lock and courtesy light outputs Variable photoelectric safety beam functions Built-in Penta Receiver Energy saving mode to reduce running costs 12 and 24 Volt DC Output to power
accessories
Service counters, password protection, holiday
mode and many more features
Built in 12 and 24 Volt battery charger for
backup batteries
12mA standby current making it ideal for solar
gates.
Are you ready for the Eclipse? The MC’s Eclipse operating system is a user friendly menu driven system that uses the 1-touch button to control, setup and run automatic gates, doors and barriers. It uses a large 4-line LCD screen showing live reading of the motor performance and status of all inputs and outputs.
The MC controller is not just the next generation but the industry game changer. We wanted to create a controller that is simple to use and does just about any feature required in the gate and door industry. The MC is not just the next generation but the “Next Transformation” in the gate and door industry creating an Eclipse over previously developed motor controllers.
This new intelligent motor controller is the best match for your automatic gate or door motors.
The intelligent controller was built from the ground up, based on customer feedback and using todays technology. With its rich functions, consumer friendly price and with the focus during development being ease of use and setup makes this controller the ultimate board to control your motors.
Elsema’s easy options to add remote controls or any type of photoelectric beams makes for a very user friendly approach, while avoiding the lockdown approach to accessories.
The control cards are available with an IP66 rated plastic enclosure for outdoor installations, backup batteries with charger or the card only. The MC is also suitable for solar gates with its low standby current of 12mA.
4
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 5
MC
MC24E or MC12E
MC24E2
Solar24 or Solar12
Part Number:
Part No. Contents Part No. Contents
MC
Double or single gate and door controller
for 24 / 12 Volt motor, card only
MC24E
Double or single controller for 24 Volt motors includes
IP66 rated plastic enclosure and transformer
MC12E
Double or single controller for 12 Volt motors includes
IP66 rated plastic enclosure and transformer
MC24E2 Same as MC24E plus 24 Volt 2.6Ah backup battery MC12E2 Same as MC12E plus 12 Volt 2.6Ah backup battery
MC24E7
Same as MC24E plus 24 Volt 7.0Ah backup battery MC12E7 Same as MC12E plus 12 Volt 7.0Ah backup battery
MC24E12
Same as MC24E plus 24 Volt 12.0Ah backup battery MC12E12 Same as MC12E plus 12 Volt 12.0Ah backup battery
Solar Gates
Solar24
Solar kit for double or single gates, includes intelligent
solar charger & 24 Volt 12.0Ah backup battery
Solar12
Solar kit for double or single gates, includes intelligent
solar charger & 12 Volt 12.0Ah backup battery
SP20* 20 Watt solar panel SP40* 40 Watt solar panel
5
www.elsema.com
Page 6
Menu Structure
Press Master Control for 2 seconds to enter the menu structure
1.0
Auto Close
1.1
Auto Close Time
1.2
AC Time with PE Trig
7.1
RC Open only
7.2
Holiday Mode
4.1
Stop & Open on Close Cycle
10.1
M2 Open Obstruct
10.2
M2 Close Obstruct
15.1
Events History
15.2
Display Operations / Currents
2.1
PA Travel Time
2.2
PA AC Time
8.1
Open Leaf Delay
8.2
Close Leaf Delay
5.1
Relay Output 1
Lock / Brake
6.1.1: Open Lock Activation 6.2.1: Courtesy Light
6.3.1: Pre-Open Warning Light
Lock / Brake
Courtesy Light
6.1.2: Close Lock Activation
6.2.3: EXIT
Courtesy Light
Service Call
6.1.3: Pre-Open Lock
Service Call
Strobe (Warning) Light
6.1.4: Pre-Close Lock
Strobe (Warning) Light
5.2
Relay Output 2
11.1
Open Speed (%)
11.2
Close Speed (%)
14.1
Enter Password
14.2
Delete Password
16.1
No. of Motors 1/2
16.2
Supply Voltage
3.1
PE Polarity
3.2
Limit Sw Polarity
9.1
M1 Open Obstruct
9.2
M1 Close Obstruct
12.1
M1 Open Anti-Jam
12.2
M1 Close Anti-Jam
6.1
Lock Output
6.2
Light Output
2.0
Pedestrian Access
3.0
Input Functions
4.0
PE Safety Beam Function
5.0
Output Functions
6.0
Output Modes
7.0
Special Features
8.0
Leaf Delay
9.0
Motor 1 Obstruct Detect Margin
10.0
Motor 2 Obstruct Detect Margin
12.0
Anti-Jam / Electronic Braking
14.0
Password
11.0
Motor Speed, Slow Speed Area & Reverse Time
13.0
Travel Learn
15.0
Operational Records
16.0
Tools
EXIT PROGRAMMING
MAIN
SCREEN
PE Beam Stops Motor
on Close Cycle
6.2.2: Day - Night Option
Locking Actuator
6
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 7
1.3
AC After Open Obstruct
7.3
Energy Saving
10.3
M2 Slow Speed Obstruct
15.3
Reset Max Current Records
15.4 EXIT
2.3
PA AC Time with PE Trig
8.3
Close Leaf Delay on Mid Open
6.4.1: Service Counters
6.3.1: Pre-Open Warning Light
6.4.2: EXIT
6.3.2: Pre-Close Warning Light
6.3.3: EXIT
5.3
EXIT
11.3
Slow Speed (%)
11.4
Open Slow Speed Area
10.4
M2 Obstruct Det Response
9.4
M1 Obstruct Det Response
11.5
Close Slow Speed Area
10.5 EXIT
9.5
EXIT
7.4
Automatic Stop/Open on Closing
7.5
Receiver Channel 2 Options
4.2
EXIT
1.5
AC on Seq. Obstruct
1.7
AC Only at Night
6.4
Service Call
2.4
PA AC on Seq. Obstruct
1.4
AC After Power Restored
1.6
AC Only When Fully Open
11.6
Stop Rev Delay Time
11.7
EXIT
14.3
EXIT
16.3
Reset Factory Default
16.4
Test Inputs
3.3
Stop Input Polarity
9.3
M1 Slow Speed Obstruct
12.3
M2 Open Anti-Jam
12.4
M2 Close Anti-Jam
12.5
Electronic Braking
6.3
Strobe (Warning) Light
16.5
Travel Timer for Slip Motors
7.6
Press and Hold, Open Input
7.7
Press and Hold, Close Input
7.8
Window / Louvre Mode
7.9
Wind Loading
PE Beam Stops Motor
on Open & Close Cycle
PE Beam Stops Motor and
Closes Gate on Open Cycle
2.6
EXIT
2.5
PA Hold Gate
16.8
Day / Night Sensitivity
16.6
Solar Gate Mode
16.7
Fuse Type : 10 or 15 Amps
12.6
Open Obstruction Operation
12.7
Close Obstruction Operation
12.8 EXIT
16.9
Slow Speed Ramp Down
1.8
EXIT
3.4
Auxiliary Input
6.6
EXIT
6.5.1: Pre-Open Lock
6.5.2: Post-Close Lock
6.5.3: EXIT
6.5
Locking Actuator
3.5
EXIT
16.10 EXIT
8.4
EXIT
7.10 EXIT
7
www.elsema.com
Page 8
MC Connection Diagram
1 2 3 4 5 6 7 8
16 15 14 13 12 11 10 9
Normally Closed User can change
Fuse
Relay
Relay
Open
Close Stop
Master
Control
AC Supply
AC Supply
AC Supply
AC Supply
AC Supply
AC Supply
Motor 1
Motor 1
AC Supply
AC Supply
Motor 2
Motor 2
AC Supply
AC Supply
Battery +
Battery -
Open Limit
Common
Motor 1
Close Limit
Motor 1
Open Limit
Motor 2
Close Limit
Motor 2
Push Button
Open
Close
Stop
Common
PED Access
Photo Beam
+ 12 VDC
- 12 VDC
Output 1 C
Output 1 NO
Output 2 C
Output 2 NC
Output 2 NO
+
-
Power
Output
LED
AC Supply : 24/12 Volts AC Model : MC
Designed by
ELSEMA
IN AUSTRALIA
Normally Closed User can change
AC Supply
DNS
Day and Night Sensor
ELSEMA
Normally Open User can change
Eclipse operating system
Powered By
Receiver
Program 2
Program 1
Antenna 1
Shield
Antenna 2
Output Rated at 250mA
12 or 24 Volts
AC Supply
Built-in
Receiver
DNS Connection : On the top right corner of the control card is a connection for Day and Night Sensor(DNS). This sensor is available from Elsema and is used to detect day and night. This feature can be used to auto close the gate at night, turn on the courtesy light or lights on your gates during the night and many more features which require a day and night detection.
8
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 9
Electrical Wiring - Supply, Motors, Battery and Inputs
Always switch off power before doing any wiring.
Make sure that all the wiring is completed and that the motor is connected to the control card. Recommended wire strip length should be 12mm for all connections to
the plug in terminal blocks.
The diagram below shows the supply, motors, battery backup and inputs available and the factory default setting for each input.
If you are using mechanical stops move to the Setup i-Learning Steps. Skip Limit Switch section.
Normally Closed User can change
Fuse
Relay
Open
Close Stop
Open Limit
Common
Motor 1
Close Limit
Motor 1
Open Limit
Motor 2
Close Limit
Motor 2
Push Button
Open
Close
Stop
Common
PED Access
Photo Beam
LED
AC Supply : 24/12 Volts AC Model : MC
Designed by
ELSEMA
IN AUSTRALIA
Normally Closed User can change
AC Supply
AC Supply
AC Supply
AC Supply
AC Supply
AC Supply
Motor 1
Motor 1
AC Supply
AC Supply
Motor 2
Motor 2
AC Supply
AC Supply
Battery +
Battery -
M
Motor 1
Motor 2
M
Normally Open User can change
12 or 24 Volts
AC Supply
9
www.elsema.com
Page 10
If you are using limit switches make sure they are connected properly. The control card can operate with either the limit switches connected directly to the cards terminal blocks or in series with the motor. Check diagrams below:
Limit Switches
Controller with
limits connected
Controller with limits
in series with motor
By default the limit switch inputs on the control card are normally closed (NC). This can be changed to normally open (NO) during the setup steps.
Normally Closed User can change
Fuse
AC Supply : 24/12 Volts AC Model : MC
Designed by
ELSEMA
IN AUSTRALIA
AC Supply
AC Supply
Motor 1
Motor 1
AC Supply
AC Supply
Motor 2
Motor 2
Open Limit
Common
Motor 1
Close Limit
Motor 1
Open Limit
Motor 2
Close Limit
Motor 2
M M
Motor 1
Motor 2
Fuse
AC Supply : 24/12 Volts AC Model : MC
Designed by
ELSEMA
IN AUSTRALIA
AC Supply
AC Supply
Motor 1
Motor 1
AC Supply
AC Supply
Motor 2
Motor 2
M
Close Limit
Open Limit
Diode* Diode*
* 6 Amps, 50V or better diode Elsema : Diode FR604
M
Close Limit
Open Limit
Diode* Diode*
10
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 11
1. The i-Learning setup can always be interrupted with the stop button or by pressing the Master Control knob.
2. Enter Menu 13 to start i-Learning or new control cards will automatically prompt you to do the i-Learning.
3. Look at the LCD and follow the instructions displayed.
4. The MC control card will open and close the gates or doors several times to learn the load and travel distances. This is the auto profiling using latest intelligent technology.
5. Buzzer will indicate learning was successful. If there was no buzzer check all electrical wiring including the power supply then go back to step 1.
6. If you hear the buzzer the gate or door is ready for use.
Setup i-Learning Steps:
11
www.elsema.com
Page 12
Auto close is a feature that automatically closes the gates/doors after a preset time has counted down to zero. The control card has a normal auto close and several special auto close features each one having its own countdown timers.
Elsema Pty Ltd recommends a photoelectric beam should be connected to the control card when any of the auto closes options are used.
If the stop button is pressed Auto Close is disabled for that cycle only. Holding the push button, open only or photoelectric beam will not allow the auto close timers to count down.
Menu No. Auto Close Features Factory
Default
Adjustable
1.1 Normal Auto Close Off 3 - 600 seconds
1.2 Auto Close with Photoelectric Trigger Off 1 - 60 seconds
1.3 Auto Close after an Open Obstruction Off 1 - 60 seconds
1.4
Auto Close after Power Restored
Off 1 - 60 seconds
1.5 Normal Auto Close on Sequential Obstructions 2
Min = Off,
Max = 5
1.6 Auto Close Only when Fully Opened Off Off/On
1.7 Auto Close Only at Night with DNS connected Off Off/On
1.8 Exit
Menu 1 – Auto Close
1.1 Normal Auto Close
The gate/door will close after this timer has counted down to zero.
1.2 Auto Close with Photoelectric Trigger
A photoelectric beam needs to be triggered before this auto close starts counting down to close the gate/door. If there is no photoelectric beam trigger the gate/door will not close.
1.3 Auto Close after an Open Obstruction
If the gate/door opens and hits an obstruction normally the gate/door will stop and remain in this position. If this feature is enabled an obstruction will start the timer count down and at zero will close the gate/door.
12
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 13
1.4 Auto Close after Power Restored
If the gate/door is open in any position and then there is a power failure, when power is reconnected the gate/door will close with this timer.
1.5 Normal Auto Close on Sequential Obstructions
If the normal auto close is set and the gate/door closes onto an object the gate/door will stop and reopen. This setting sets the amount of times the gate/door will try to auto close. After trying for the set limit the gate/door will remain open.
1.6 Auto Close Only when Fully Opened
The auto close timer will not time out unless the gates/doors are fully opened.
1.7 Auto Close Only at Night
When the DNS is connected and the sensitivity (Menu 16.8) is set correctly the auto close will only work at night.
Menu 2 – Pedestrian Access
There are several types of Pedestrian access modes. Pedestrian access opens the gate/door for a short time to allow someone to walk through the gate/door but does not allow a vehicle access.
Elsema Pty Ltd recommends a photoelectric beam should be connected to the control card when any of the auto closes options are used.
Menu No. Pedestrian Access Features Factory
Default
Adjustable
2.1
Pedestrian Access Travel Time
3 seconds 3 - 20 seconds
2.2
Pedestrian Access Auto Close Time
Off 0 - 60 seconds
2.3
Pedestrian Access Auto Close Time with PE trigger
Off 0 - 60 seconds
2.4 Pedestrian Access Auto Close on Sequential Obstructions 2
Min = Off,
Max = 5
2.5 Pedestrian Access with Hold Gate Off Off/On
2.6 Exit
13
www.elsema.com
Page 14
2.1 Pedestrian Access Travel Time
This sets the time the gate/door opens when a pedestrian access input is activated.
2.2 Pedestrian Access Auto Close Time
This sets the countdown timer for automatically closing the gate/door when a pedestrian access input is activated.
2.3 Pedestrian Access Auto Close Time with PE Trigger
This sets the countdown timer for automatically closing the gate/door when a photoelectric beam is triggered and pedestrian access input is activated.
2.4 Pedestrian Access Auto Close on Sequential Obstructions
If the pedestrian access auto close is set and the gate/door closes onto an object the gate/door will stop and reopen. This setting sets the amount of times the gate/door will try to auto close. After trying for the set limit the gate/door will remain open.
2.5 Pedestrian Access with Hold Gate
If the pedestrian access hold gate is ON and the Pedestrian access input is permanently activated the gate will remain open in the pedestrian access position. Open input, Close input, Push Button input and remote controls are disable. Used in Fire Exit applications.
Menu 3 – Input Functions
This allows you to change the Polarity of photoelectric beam, stop and limit switch inputs.
Menu No.
Input Functions
Factory Default
Adjustable
3.1 Photoelectric Beam Polarity Normally Closed
Normally Closed /
Normally Open
3.2 Limit Switch Polarity Normally Closed
Normally Closed /
Normally Open
3.3 Stop Input Polarity Normally Open
Normally Open / Normally Closed
3.4* Auxiliary Input (M2 Open Limit Terminal) Disabled
Disable /
Safety Bump Strip
3.5 Exit
14
Double Gate & Door Controller with Eclipse® Operating System (EOS)
* 3.4: This option is only available when used for single gate mode
Motor 2 Open Limit terminal can be used to wire Elsema’s safety bump strip on a single gate application.
Page 15
The photoelectric beam is placed across the gate/door and when it is broken it can operate the gate/door to do certain functions.
Menu No. Photoelectric
Beam Feature
Factory Default
Adjustable
4.1 Photoelectric Beam
PE Beam stops and opens
gate/door on close cycle
PE Beam stops and opens
gate/door on close cycle
-----------------------------------­PE Beam stops gate/door
on close cycle
-----------------------------------­PE Beam stops gate/door
on open & close cycle
------------------------------------
PE Beam stops and closes
gate/door on open cycle
4.2
Exit
The factory default for the PE beam input is “normally closed” but this can be changed to normally open. To change it go back to Menu 3.
Elsema Pty Ltd recommends a photoelectric beam should be connected to the control card when any of the auto closes options are used.
Elsema sells several different types of photoelectric beams. We stock Retro-Reflective and Through Beam photoelectric beams.
PE24
(Through-Beam type)
Menu 4 – Photoelectric Beam
PE1500
(Retro-Reflective Type)
15
www.elsema.com
Page 16
The control card has two relay outputs, Output 1 and Output 2. The user can change the function of these outputs to lock / brake, courtesy light, service call, strobe (Warning) light indicator or locking actuator.
Output 1 is a voltage free relay output with common, normally open and normally closed contacts. Factory default is lock / brake release function.
Output 2 is a voltage free relay output with common, normally open and normally closed contacts. Factory default is courtesy light function.
Menu No. Relay Output
Function
Factory Default
Adjustable
5.1 Relay Output 1 Lock / Brake
Lock / Brake
-----------------------------------­Courtesy Light
------------------------------------
Service Call
------------------------------------
Strobe (Warning) Light
------------------------------------
Locking Actuator
5.2 Relay Output 2 Courtesy Light
Lock / Brake
-----------------------------------­Courtesy Light
------------------------------------
Service Call
------------------------------------
Strobe (Warning) Light
5.3 Exit
Menu 5 – Relay Output Functions
16
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 17
Lock / Brake Output
This output is used to power an electrical lock or a motor brake release. The factory default for the lock/ brake release is on output 1. Output 1 is a voltage-free relay contact with common and normally open contacts. Having it voltage-free allows you to connect either 12VDC/AC, 24VDC/AC or 240VAC to the common. The normally open contact drives the lock/brake. See diagram below:
Courtesy Light
This output is used to power a courtesy light. The factory default for the courtesy light is on output 2. Output 2 is a voltage-free relay contact with common, normally open and normally closed contacts. Having it voltage-free allows you to connect either 12VDC/AC, 24VDC/AC or 240VAC supply to the common. The normally open contact drives the light. See diagram on the next page.
Relay
Relay
Open
Close Stop
Output 1 C
Output 1 NO
Supply
+ if DC
- if DC
12VDC or
24VDC
Lock/Brake
Service Call Output
Either output 1 or output 2 can be changed to service call indicator. This will trigger the output when the software service counter is reached. Used to alert installers or owners when the gate/door is to be serviced. Use Elsema’s GSM-1000 receiver allows installers or owners to get a SMS message when the service is due.
17
www.elsema.com
Page 18
Strobe (Warning) Light when Opening or Closing
The relay output is activated whenever the gates/doors are operating. The factory default is Off. Either output 1 or output 2 can be changed to strobe (Warning) light. Both relay outputs are voltage-free contacts. Having it voltage-free allows you to connect either 12VDC/AC, 24VDC/AC or 240VAC supply to the common to power the strobe light. Then the normally open contact drives the light. See diagram above.
Relay
R e c e i v e r
Master Control
Output 2 C
Output 2 NC
Output 2 NO
+
-
Unfiltered DC Output
Ouput voltage depends
on supply voltage
+ if DC
- if DC
240VAC supply
24VAC/DC or
Depends on the light
12VAC/DC
Locking Actuator
Locking actuator mode uses both relay output 1 and relay output 2. The 2 outputs are used to change the polarity of the locking actuator to lock and unlock during opening and closing cycle. During pre­open relay output 1 is “ON” and during post-close relay output 2 is “ON”. Pre-open and post-close times are adjustable.
18
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 19
Menu 6.1 – Lock / Brake Output Modes
The relay output in the lock / brake mode can be configured in different ways.
Menu No. Lock / Brake Modes Factory
Default
Adjustable
6.1.1 Open Lock / Brake Activation 2 seconds
0 – 30 seconds
or hold
6.1.2 Close Lock / Brake Activation Off
0 – 30 seconds
or hold
6.1.3 Open Pre-Lock / Brake Activation Off 0 – 30 seconds
6.1.4 Close Pre-Lock / Brake Activation Off 0 – 30 seconds
6.1.5
Exit
6.1.1 Open Lock / Brake Activation
This sets the time the output is activated. Factory default is 2 seconds. Setting it to Hold means the output is activated for the total travel time in the open direction.
6.1.2 Close Lock / Brake Activation
This sets the time the output is activated. Factory default is off. Setting it to Hold means the output is activated for the total travel time in the close direction.
6.1.3 Open Pre-Lock / Brake Activation
This sets the time the output is activated before the motor starts in the open direction. Factory default is Off.
6.1.4 Close Pre-Lock / Brake Activation
This sets the time the output is activated before the motor starts in the close direction. Factory default is Off.
19
www.elsema.com
Page 20
Menu 6.2 – Courtesy Light Output Mode
The relay output in the courtesy mode can be adjusted from 2 seconds to 18 hours. This sets the time the courtesy light is activated. Factory default is 1 minute.
Menu No. Courtesy Light Mode Factory
Default
Adjustable
6.2.1 Courtesy Light Activation 1 minute
2 seconds to
18 hours
6.2.2
Courtesy Light at Night Only with
LDR Connected
Off Off/On
6.2.3 Exit
Menu 6.3 – Strobe (Warning) Light Output Mode
The relay output in the strobe (Warning) mode can be configured in different ways:
Menu No. Strobe (Warning) Light Mode Factory
Default
Adjustable
6.3.1
Pre-Open Strobe (Warning)
Light Activation
Off 0 – 30 seconds
6.3.2
Pre-Close Strobe (Warning)
Light Activation
Off 0 – 30 seconds
6.3.3
Exit
6.3.1 Pre-Open Strobe Light Activation
This sets the time the strobe light is activated before the gate/door operates in the open direction. Factory default is Off.
6.3.2 Pre-Close Strobe Light Activation
This sets the time the strobe light is activated before the gate/door operates in the close direction. Factory default is Off.
20
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 21
Menu 6.4 – Service Call Output Mode
This sets the number of complete cycles (Open and Close) required before the built-in buzzer is activated. Also the control card outputs can be configured to be activated if the number of cycles is completed. Connecting Elsema’s GSM-1000 alert receiver to the output allows owners to get a phone call or SMS message when the service is due.
When “Service Call Due” message shows up on the LCD a service call is required. After service has been done, follow the messages on the LCD.
Menu No.
Service Call Mode
Factory Default
Adjustable
6.4.1 Service Counter Off Min: 2000 to Max: 50,000
6.4.2
Exit
Menu 6.5 – Locking Actuator Output Mode
The time for which relay output 1 turns “on” before the gate/door starts to open and the time for which relay 2 turns “on” after the gate/door is fully closed can be adjusted as below:
Menu No. Locking Actuator Factory
Default
Adjustable
6.5.1 Pre-Open Lock Activation Off 0 – 30 seconds
6.5.2 Post-Close Lock Activation Off 0 – 30 seconds
6.5.3 Exit
6.5.1 Pre-Open Locking Actuator Activation
This sets the time relay 1 is activated before the gate/door operates in the open direction. Factory default is Off.
6.5.2 Post-Close Locking Actuator Activation
This sets the time relay 2 is activated after the gate/door is fully closed. Factory default is Off.
21
www.elsema.com
Page 22
The control card has many special features that can all be customised to your specific application.
Menu No. Special Features Factory
Default
Adjustable
7.1 Remote Control Open Only Off
Off/On
7.2 Holiday Mode Off Off/On
7.3 Energy Saving Mode Off Off/On
7.4 Automatic Stop/Open on Closing On Off/On
7.5
Receiver Channel 2 Options Off Off / Light / Pedestrian Access
7.6 Press and Hold for Open Input Off Off/On
7.7 Press and Hold for Close Input Off Off/On
7.8 Window / Louvre Off Off/On
7.9 Wind Loading Off Off/On
7.10 Exit
7.1 Remote Control Open Only
By default the remote control allows the user to open and close the gates/doors. In public access areas user should only be able to open the gates/doors and not worry about closing it. Usually the auto close is used to close the gates/doors. This mode disables closing for the remote controls.
7.2 Holiday Mode
This feature disables all the remote controls.
7.3 Energy Saving Mode
This puts the control card to very low standby current that reduces your electricity bill while still maintaining normal functions and operations.
Menu 7 – Special Features
22
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 23
Leaf delay is used when one gate leaf will close in an overlapping position to the first closed leaf. This leaf delay may also be necessary for special add-on locking pins. The control card has separate leaf delay for the open and close directions.
When the control card is used with a single motor the leaf delay mode is disabled.
Menu No. Leaf Delay Factory
Default
Adjustable
8.1 Open Leaf Delay 3 seconds Off - 25 seconds
8.2 Close Leaf Delay 3 seconds Off - 25 seconds
8.3
Exit
8.1 Open Leaf Delay
Motor 1 will start opening first. After leaf delay time has expired motor 2 will start opening.
8.2 Close Leaf Delay
Motor 2 will start closing first. After leaf delay time has expired motor 1 will start closing.
8.3 Close Leaf Delay on Mid Stop
By default motor 1 will always have delay when closing even if the gate is not fully open. When disabled both motor 1 and motor 2 will start closing at the same time only when not fully open.
Menu 8 – Leaf Delay
7.4 Automatic Stop / Open on Closing
By default if the gates/doors is closing and a push button or remote control is activated it will automatically stop and open the gates/doors. When this feature is disabled then the gates/doors will stop on an activation of the push button or remote control.
7.5 Receiver Channel 2 Options
The receivers 2nd channel can be programmed to control a courtesy light or can be used as pedestrian access.
7.6 & 7.7 Press and Hold for Open and Close Inputs
If this feature is ON the user must continuously press the open or close input for it to be activated.
7.8 Window or Louvre Mode
This mode optimises the control card for operating electronic windows or louvres.
23
www.elsema.com
Page 24
Menu 9 – Motor 1 Obstruction Detect Margins
This sets the current sensitivity margin above the normal run current to trip the gates/doors if an obstruction is detected. Different obstruction margins can be set for the open and close direction. Also the response time is adjustable.
The minimum margin will allow least pressure applied to trip the gates/doors if it hits an object. The maximum margin will allow for a large amount of pressure applied to trip the gates/doors if it hits an object.
Menu No. Motor 1 Obstruction Detect Margins
and Response Time
Factory Default Adjustable
9.1 Open Obstruction Margin 1 Amp 0.5 - 6.0 Amps
9.2 Close Obstruction Margin 1 Amp 0.5 - 6.0 Amps
9.3
Open and Close Slow Speed
Obstruction Margin
1 Amp 0.5 - 6.0 Amps
9.4 Obstruction Detect Response Time Medium
Fast, Medium
and Slow
9.5
Exit
Margin Example
Motor is running at 2 Amps and the margin is set to 1.5 Amps, an obstruction detect will occur at
3.5 Amps (Normal Running Current + Margin).
For high margin settings the supply transformer should be large enough to supply the high margin current.
If the gates/doors hits an object on closing it will automatically stop and then re-open. If the gates/doors hit an object on opening it will automatically stop.
24
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 25
Menu 10 – Motor 2 Obstruction Detect Margins
This sets the current sensitivity margin above the normal run current to trip the gates/doors if an obstruction is detected. Different obstruction margins can be set for the open and close direction. Also the response time is adjustable.
The minimum margin will allow least pressure applied to trip the gates/doors if it hits an object. The maximum margin will allow for a large amount of pressure applied to trip the gates/doors if it hits an object.
Menu No. Motor 2 Obstruction Detect Margins
and Response Time
Factory Default Adjustable
10.1 Open Obstruction Margin 1 Amp 0.5 - 6.0 Amps
10.2 Close Obstruction Margin 1 Amp 0.5 - 6.0 Amps
10.3
Open and Close Slow Speed
Obstruction Margin
1 Amp 0.5 - 6.0 Amps
10.4 Obstruction Detect Response Time Medium
Fast, Medium
and Slow
10.5
Exit
Margin Example
Motor is running at 2 Amps and the margin is set to 1.5 Amps, an obstruction detect will occur at
3.5 Amps (Normal Running Current + Margin).
For high margin settings the supply transformer should be large enough to supply the high margin current.
If the gates/doors hits an object on closing it will automatically stop and then re-open. If the gates/doors hit an object on opening it will automatically stop.
25
www.elsema.com
Page 26
Menu 11 – Motor Speed, Slow Speed Area
and Reverse Time
Menu No. Motor Speed, Slow Speed
Area and Reverse Time
Factory Default
Adjustable
11.1 Open Speed 80% 50% to 125%
11.2 Close Speed 70% 50% to 125%
11.3 Open and Close Slow Speed
50%
35% to 65%
11.4 Open Slow Speed Area 4 1 to 12
11.5 Close Slow Speed Area 5 1 to 12
11.6 Stop Reverse Delay 0.4 seconds 0.2 to 2.5 seconds
11.7
Exit
11.1 & 11.2 Open and Close Speed
This sets the speed at which the gates/doors will travel. If the gate/door is travelling too fast reduce this
value.
11.3 Slow Speed
This sets the speed at which the gates/doors will travel in the slow speed region. If the gates/doors is travelling too slow increase this value.
11.4 & 11.5 Slow Speed Area
This sets the slow speed travel area. If you want more travel time for the slow speed area increase this value.
11.6 Obstruction Stop Reverse Delay Time
This sets the stop and reverse delay time when the gates/doors hits an obstruction.
26
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 27
Menu 12 – Anti-Jam, Electronic Braking and Gate Movement after Obstruction
Menu No. Anti-Jam or
Electronic Braking
Factory Default
Adjustable
12.1
Motor 1 Open Anti-Jam
OFF 0 to 2.0 seconds
12.2
Motor 1 Close Anti-Jam
OFF 0 to 2.0 seconds
12.3
Motor 2 Open Anti-Jam
OFF 0 to 2.0 seconds
12.4
Motor 2 Close Anti-Jam
OFF 0 to 2.0 seconds
12.5 Electronic Braking OFF Off/On
12.6
Opening Direction : Gate Movement after
Obstruction
Stop
Stop / Reverse for 2 sec /
Reverse Fully
12.7
Closing Direction : Gate Movement after
Obstruction
Reverse for 2
seconds
Stop / Reverse for 2 sec /
Reverse Fully
12.8 Exit
12.1 and 12.2 Motor 1 Open and Close Anti-Jam
When the gates/doors are in the fully open or fully closed position this feature applies a reverse voltage for a very short time. It will prevent the motor from jamming up the gates/doors so it is easy to
disengage the motors for manual operation.
12.3 and 12.4 Motor 2 Open and Close Anti-Jam
When the gates/doors are in the fully open or fully closed position this feature applies a reverse voltage for a very short time. It will prevent the motor from jamming up the gates/doors so it is easy to
disengage the motors for manual operation.
12.5 Electronic Braking
This will stop the motors with an electronic brake. Brake applies to obstruction and Stop inputs.
12.6 Opening Direction : Gate Movement after Obstruction
After an obstruction has occurred the gate will either stop, reverse for 2 seconds or reverse fully.
12.7 Closing Direction : Gate Movement after Obstruction
After an obstruction has occurred the gate will either stop, reverse for 2 seconds or reverse fully.
27
www.elsema.com
Page 28
Menu 15 – Operational Records
This is for information only.
Menu No. Operational Records
15.1 Event History, up to 100 events are recorded in the memory
15.2 Displays Gates/Doors Operations and Currents Levels
15.3
Reset Maximum Current Records
15.4
Exit
15.1 Event History
The event history will store 100 events. The following events are recorded into the memory: Power On, Low Battery, All input activations, Successful opening, Successful closing, Obstruction Detected, Unsuccessful i-Learning Attempt, Factory Reset, DC Output Overloaded, AC Supply Failed, AC Supply Restored, Autoclose, Security Close and Fuse Protect Obstruction.
15.2 Displays Gates/Doors Operations and Current Levels
This displays the number of open cycles, close cycles, pedestrian cycles, open obstructions, close obstructions and both motor current levels. All maximum current values can be reset by the user from Menu 15.3
Menu 14 – Password
This will allow the user to enter a password to prevent unauthorised users from entering the control card settings. User must remember the password. The only way to reset a lost password is to send the control card back to Elsema.
To delete a password select Menu 14.2 and press Master Control.
Menu 13 – i-Learning
This feature allows you to do the intelligent travel learning of the gates/doors. Follow the messages on the LCD to complete the learning
28
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 29
16.1 Number of Motors
This allows you to manually set the control card to a single motor or a double motor. The control card will automatically test for motors connected during setup.
16.2 Set the Supply Voltage
This allows you to manually set the control card to 12 or 24 Volt supply. The control card will automatically set the correct supply voltage during setup. To use the control card in a solar application you must set the correct voltage in the Tools. This will disable the automatic voltage sensing which could causes problems in solar applications.
16.3 Resets Controller
Reset all settings to factory default. Also removes password.
16.4 Test Inputs
This allows you to test all the external devices connected to the controllers inputs. UPPERCASE means input is activated and lowercase means input is deactivated.
16.5 Travel Timer for Slip Clutch Motors
This allows you to use the controller with travel timers. Motor 1 and 2 can have separate travel timers up to 120 seconds. Used for Hydraulic Motors.
16.9 Slow Speed Ramp Down Time
This allows you to change the time it takes the gate/door to change its speed from fast to slow.
Menu 16 – Tools
Menu No.
Tools
16.1 Number of Motors, Single or Double Gate System
16.2
Set the Supply Voltage : 12 or 24 Volts
16.3
Resets Controller to Factory Settings
16.4
Test Inputs
16.5 Travel Timer for Slip Clutch Motors
16.6 Solar Gate Mode : Optimises the Control Card for Solar Applications
16.7
Fuse Type : 10 or 15 Amps
Optimises the Control Card for the correct Blade Fuse used
16.8 Day and Night Sensitivity Adjustment for the DNS
16.9 Slow Speed Ramp Down Time
16.10 Exit
29
www.elsema.com
Page 30
Accessories
Battery Charger
The control card has a built in charger for backup batteries. Simply connect the batteries to the battery terminal and the charger will automatically charge the batteries. This allows you to use your gates or doors when the mains power has failed. The control card built-in charger is not suitable for solar applications.
Solar Applications
Solar applications use Elsema solar charger, CMP12 to charge the batteries and SP20 or SP40 solar panels. Solar gate controller kits are available.
WARNING
To use the control card in a solar application you must set the correct voltage input in the Tools Menu (16.2). This will disable the automatic voltage sensing which could causes problems in solar applications.
Backup Batteries
Elsema has backup batteries perfectly matched to the control card. Three sizes are available:
Lab12-12, 12 Volt 12 AH Rechargeable, ideal for solar and industrial gates and doors.
Lab12-7.0, 12 Volt 7.0 AH Rechargeable, ideal for solar and industrial gates and doors
Lab12-2.6, 12 Volt 2.6 AH Rechargeable, ideal for domestic gates and doors
Backup Batteries
Solar Panels
SP20 & SP40
30
Double Gate & Door Controller with Eclipse® Operating System (EOS)
Page 31
PentaCODE® Remotes
Penta Repeater can increase the
operating range of the keyring
remotes to up to 500 metres.
PentaFOB® Remotes
Keyring Remotes
The latest PentaCODE
®
and PentaFOB® keyring remotes ensure your gates or doors are secure. Visit www.elsema.com for more details.
Photoelectric Beam
Elsema has several types of photoelectric beams including retro-reflective and through beam with IP-66 ratings.
Flashing
Lights
Flashing Lights
Elsema has several flashing lights to act as a warning when the gate or doors is in operation.