SA68PP
GB
DUO PIR MOTION DETECTOR
Allow your pet freely moving
without alarm trigger
D
DUO PIR-BEWEGUNGSMELDER
Ihr Haustier kann sich freibewegen ohne
Alarm auszulösen
www.elro.eu
GB
SPECIFICATIONS
Battery : Type CR123A 3V/1700mAh
Warm Up Time : About 1 minute
Detection Coverage : 12m x 90° at 2 meters height & below 28°C
Pet Immunity Height : Height ≦60cm; Length≦90cm
Working temp : -10°C - +40°C
* specifications are subject to change without notice.
SA68PP
smartwares
safety & lighting b.v.
Broekakkerweg 15
5126 BD Gilze
The Netherlands
WWW.ELRO.EU
SPECIFICATIONS
Batterie : Typ CR123A 3V/1700mAh
Aufwärmzeit : etwa 1 Minute
Erkennung Reichweite : 12m x 90° bei 2M Höhe und unter 28° C
Pet Immunity : Höhe ≦60cm; Länge ≦90cm
Betriebstemperatur : -10 ° C - +40 ° C
* Spezifikationen können ohne Ankündigung geändert werden.
868,35MHz.
R&TTE APPROVED
GB
SAFETY AND MAINTENANCE INSTRUCTIONS
DD
SICHERHEITS- UND WARTUNGSHINWEISE
CONFORMITY
Hereby, Smartwares declares that this equipment is in compliance with
the essential requirements and other relevant provisions of Directive
1999/5/EC. For the document of conformity go to www.elro.eu or scan
the QR code
1a
2
3
75 METRE
WIRELESS
1
USE
INDOOR
INCL. CR123A
LITHIUM
BATTERY
1b
AUTOMATIC
HOUSECODE
RANGE 12m x 90°
DETECTION
GUARANTEE
4
5
6
2 YEAR
2a
2b
smartwares
safety & lighting b.v.
Broekakkerweg 15
5126 BD Gilze
The Netherlands
WWW.ELRO.EU
SA68PP
868,35MHz.
R&TTE APPROVED
3 4
+
+
5
5b 5b
UP
5a
5a
KONFORMITÄTS-ERKLÄRUNG
Hiermit erklärt Smartwares, dass sich das Gerät in Übereinstimmung
mit den grundlegenden Anforderungen und den übrigeneinschlägigen
Bestimmungen der Richtlinie 1999/5/EG befindet. Die Konformitätserklärung finden Sie auf www.elro.eu oder scannen Sie den QR-Code
6
+ = ALARM
3
2
1
2 3 4 5 6 7
9 10 11
8
12m1
GB D
DUO PIR MOTION DETECTOR
PRODUCT OVERVIEW
1 Front Cover
2 Upper Lens
3 Lower Lens
4 Tamper button
5 Test button
6 Battery Compartment
These instructions should be read in conjunction with your System
Installation and Operating Manual and be retained for future
reference.
INTRODUCTION
SA68PP Passive Infra-Red Motion Detector is designed for use with
a designated Control Panel, operating at 868MHz only. And it
features pet immunity, allowing your pet to move freely without
causing false alarms. PIR detectors are designed to detect
movement in a protected area by sensing the changes of thermal
radiation caused by the moving body within or across the field of
detection. This product should be connected to a control system
for alert signal transmitting. When the detector is triggered, an
alarm signal will be emitted and the Control Panel, after receiving
the signal, will perform certain action according to its settings. This
product comes with temperature compensation feature for
constant detection range through all seasons.
CHOOSING A MOUNTING LOCATION
The PIR detector is suitable for mounting indoor indry interior
locations only. The recommended position for the PIR detector is
on the wall of a room mounted at a height of 2m. At this height, the
detector will optimize the detection range of up to 12m with a field
of view of 90°. When considering and deciding mounting position
for the detector the following points should be considered:
1. Do not locate the detector facing a window or where it is
exposed to or facing direct sunlight. PIR Detectors are not
suitable for use in conservatories.
2. Do not locate the detector where it is exposed to ventilators.
3. Do not locate the detector directly above a heat source, (e.g.
fire, radiator, boiler, etc).
4. Where possible, mount the detector in the cornerof the room
so that the logical path of an intruder would cut across the
detection zone. PIR detectors respond (2a) more effectively to
movement across the detection area than to movement
directly towards the sensor (2b).
5. Do not locate the detector in a position where it is subject to
excessive vibration.
6. Ensure that the position selected for the PIR detector is
within effective range of the system, (refer to System
Installation and Operating Manual).
GETTING STARTED - CODE LEARNING
In order to communicate with the Control Panel, theID code of the
PIR detector needs to be learned by the Control Panel. Follow these
steps to implement the code learning:
1. Undo and remove the fixing screw located at the bottom of
the PIR detector. Then carefully open the rear cover (3).
2. Insert the battery into the battery compartment.Note the
polarity of battery must be correct as indicated (4).
Note:The PIR detector adopts a CR123A 3V Lithium battery
which under normal conditions will have typical life of up to 3
years. When battery power level drops to low, the LED on the
detector will flash for 1 second upon movement detection in
Normal mode. Battery Low signal will also be transmitted to
Control Panel. When this occurs the battery should be
replaced as soon as possible.
3. The PIR detector will take about 1 minute to warm up. During
the period the LED will flash repeatedly at 2-second intervals.
After warming up, the LED will turn off and the PIR detector
is ready to operate. Note:During warm-up period, the PIR
detector can still be set into TEST mode.
4. Press and hold the Tamper button so that the PIR detector
does not emit the ID code (1b-4). In the meantime,
operate the Control Panel to prepare for learning the PI
detector’s ID code. Refer to the Control Panel’s operation
guide for information on configuring the learning mode.
5. When the Control Panel is ready to learn the PIR detector’s
(1a + 1b)
TESTING THE PIR DETECTOR
1. Press and hold the Test button on the PIR detector for over 2
seconds, and the PIR detector will enter TEST mode (1b-5).
2. Walk into and move slowly around the protected area. Each
time the PIR detects movement the LED behind the lens will
flash for 0.5 second (in Normal mode the LED will not flash
on movement detection). The Control Panel will be notified of
the trigger event as well.
3. If for more than 3 minutes no movement is detected, the PIR
detector will exit Test mode and enter Normal mode
automatically.
4. It is recommended that the operation of the detector is also
tested with the alarm in Normal mode to ensure that the
detector will successfully trigger a Full Alarm condition and
that the detector is operating on the correct zone (if installed
on a multi-zone alarm system). Please refer to your System
Installation and Operating manual for more information.
5. After testing is done, refit the rear cover of the detector or
continue with the mounting process.
MOUNTING THE PIR DETECTOR (5)
1. Remove the rear cover if it is fixed to the mainbody. Use the
rear cover as a template to mark the positions of the fixing
holes on the wall (5a).
2. Fix the rear cover to the wall using the supplied screws and
wall plugs. Do not over-tighten the fixing screws as this may
distort or damage the cover.
3. Replace the main body to the rear cover and refit the fixing
screw in the bottom of the PIR to secure the main body. Do
not over-tighten the fixing screw as this may damage the
casing.
4. This unit can be mounted on a flat wall or in a corner. Choose
a proper location according to your requirements (5b).
Flat wall mounting Corner mounting
NORMAL MODE OPERATIONS
Under Normal operation mode, the PIR detector will function as the
following:
1. Whenever a Tamper event occurs, the PIR detector will report
to the Control Panel. For battery power saving concern, the
maximum times of transmitting effective alert signals are
limited to 7 times within 2 minutes time frame. And the
detector will re-transmit further alert signals only after 2
minutes stillness.
2. When the PIR detector is triggered, it will not be triggered
again for the next 5 seconds to save battery power. The PIR
detector has self-test function to report to Control Panel
approximately every 50 minutes as a supervisory signal. The
tamper or battery low condition will be reported along with
the signal transmitting.
BATTERY STATUS DETECTION (only higher systems)
1. When the PIR detector reports to Control Panel every 50
minutes, the status of battery will also be reported.
2. In the event of a PIR Tamper or movement detection, the
status of battery will also be reported.
3. When Low Battery status occurs, the LED light will flash for 1
second every time the PIR detector is triggered. If this
condition occurs, you should replace the PIR detector’s
battery with a new one as soon as possible. Note:Under TEST
mode the LED will also flash when the PIR detector is
triggered. To distinguish the two conditions: the LED flash in
Test mode only lasts for 0.5 second while under Low Battery
the flash lasts for 1 second.
4. When Low Battery status occurs, the detector will keep in
battery low status and stop measuring battery level for
saving power. The Low Battery status will not be changed
until the battery is replaced by a new one and the PIR
detector re-powered on.
PET IMMUNITY (6)
This product comes with pet immunity mechanism so that small
pets or animals will not trigger the detector and cause false
alarms. As shown in the figure below: the person is taller so he will
trigger the PIR detector when he walks into the detection zone. On
the other hand, the pet is small so it will not cause the alarm.
However, the pet’s height and length must not exceed 60cm/90cm
respectively to avoid triggering the detector.
NOTE: Works only with one pet
code, release the Tamper button on the PIR detector to emit
the ID code.
6. Follow the Control Panel’s prompts to operate. After the
Control Panel receives the code and indicates that the code is
learned correctly, the learning process is complete.Do not fix
the rear cover yet and proceed with the test of PIR detector.
DUO PIR-BEWEGUNGSMELDER
PRODUKTÜBERBLICK (1a + 1b)
1 Frontabdeckung
2 Obere Optik
3 Untere Optik
4 Sabotagetaste
5 Testtaste
6 Batteriefach
Lesen Sie diese Anleitungen in Verbindung mit der Installationsund Betriebsanleitung Ihres Systems. Bewahren Sie die
Anleitungen für späteres Nachschlagen auf.
EINLEITUNG
Der passive Infrarot-Bewegungsmelder SA68PP ist zur Nutzung
mit einer designierten Alarmzentrale konzipiert, die auf 868 MHz
arbeitet. Er ist mit Unanfälligkeit für Haustiere ausgestattet; Ihr
Haustier kann sich frei bewegen, ohne einen Fehlalarm
auszulösen. PIR-Melder sind zur Erkennung von Bewegung im
geschützten Bereich konzipiert, indem sie Veränderungen der
Wärmeabstrahlung aufnehmen, die von einem Körper ausgehen,
der sich durch den geschützten Bereich bewegt. Dieses Gerät
muss an einer Alarmzentrale angeschlossen werden. Beim
Auslösen des Melders wird ein Alarmsignal übertragen und die
Alarmzentrale führt nach dem Empfang des Signals bestimmte
Aktionen entsprechend der Einstellung aus. Das Gerät ist mit
einer Temperaturkompensationsfunktion für einen
kontinuierlichen Erkennungsbereich für alle Jahreszeiten
ausgestattet.
MONTAGEORT WÄHLEN
Der PIR-Melder ist nur zur Innenmontage in trockener Umgebung
geeignet. Die empfohlene Position für den PIR-Melder ist an der
Wand in einer Höhe von 2 m. In dieser Höhe optimiert der Melder
den Erkennungsbereich auf bis zu 12 m in einem Winkel von 90°.
Bei der Entscheidung für einen Montageort für den Melder
berücksichtigen Sie bitte die nachstehenden Punkte:
1. Richten Sie den Melder nicht auf ein Fenster aus und montieren
Sie ihn nicht in direkter Sonneneinstrahlung. PIR-Melder sind
nicht zur Benutzung in Wintergärten geeignet.
2. Montieren Sie den Melder nicht im Bereich von Ventilatoren.
3. Montieren Sie den Melder nicht direkt über einer Wärmequelle
(wie Kamin, Heizkörper, Boiler usw.).
4. Montieren Sie den Melder möglichst in einer Zimmerecke,
sodass der logische Pfad eines Eindringlings quer durch den
Erkennungsbereich verläuft. PIR-Melder reagieren (2a)
effektiver auf Bewegung quer durch den Erkennungsbereich,
als auf den Melder zu (2b).
5. Montieren Sie den Melder nicht in einer Position, in welcher er
übermäßiger Vibration ausgesetzt ist.
6. Achten Sie darauf, dass der für den PIR-Melder gewählte
Montageort innerhalb der Reichweite des Systems liegt (siehe
Installations- und Betriebsanleitung des Systems).
ERSTE SCHRITTE - CODE ÜBERNEHMEN
Zur Kommunikation mit der Alarmzentrale muss der ID-Code des
PIR-Melders durch die Alarmzentrale übernommen werden.
Folgen Sie den nachstehenden Schritten zur Übernahme des
Codes:
1. Lösen Sie die Schraube unten am PIR-Melder und öffnen Sie
vorsichtig die rückseitige Abdeckung (3).
2. Setzen Sie die Batterie in das Batteriefach ein. Beachten Sie
die korrekte Polarität (4).
Hinweis: Der PIR-Melder benutzt eine CR123A 3-VLithiumbatterie, die unter normalen Umständen eine
Lebenserwartung von bis zu 3 Jahren hat. Fällt die
Batteriespannung ab, so blinkt die LED auf dem Melder im
Normalmodus bei Bewegungserkennung für 1 Sekunde. Das
Signal für geringe Batteriekapazität wird ebenfalls an die
Alarmzentrale übertragen. In diesem Fall muss die Batterie
kurzfristig ausgetauscht werden.
3. Der PIR-Melder benötigt ca. 1 Minute zum Aufwärmen.
Während dieses Zeitraums blinkt die LED in 2-SekundenIntervallen. Anschließend schaltet sich die LED aus und der
PIR-Melder ist betriebsbereit. Hinweis: Während der
Aufwärmphase kann der PIR-Melder auf TESTMODUS
eingestellt werden.
4. Halten Sie die Sabotagetaste gedrückt, sodass der PIR-Melder
den ID-Code nicht überträgt (1b-4). In der Zwischenzeit
bereiten Sie die Alarmzentrale auf die Übernahme des IDCodes des PIR-Melders vor. Informationen zur Konfiguration
des Übernahmemodus finden Sie in der Bedienungsanleitung
der Alarmzentrale.
5. Sobald die Alarmzentrale zur Übernahme des ID-Codes des
PIR-Melders bereit ist, lassen Sie die Sabotagetaste auf dem
PIR-Melder los, um den ID-Code zu übertragen.
6. Folgen Sie den Anleitungen zum Betrieb der Alarmzentrale.
Nachdem die Alarmzentrale den Code empfangen hat und
anzeigt, dass der Code korrekt übernommen wurde, ist der
Übernahmeprozess beendet. Schließen Sie noch nicht die
rückseitige Abdeckung und fahren Sie mit dem Test des PIRMelders fort.
PIR-MELDER TESTEN
1. Halten Sie die Testtaste auf dem PIR-Melder für wenigstens 2
Sekunden gedrückt; der PIR-Melder begibt sich in den
TESTMODUS (1b-5).
2. Begeben Sie sich in den gesicherten Bereich und gehen Sie
langsam darin umher. Bei jeder Bewegungserkennung durch
den PIR-Melder blinkt die LED hinter der Optik für 0,5
Sekunden (im Normalmodus blinkt die LED nicht bei
Bewegungserkennung). Die Auslösung wird an die
Alarmzentrale übertragen.
3. Wird für mehr als 3 Minuten keine Bewegung erkannt, so
verlässt der PIR-Melder den Testmodus und begibt sich
automatisch in den Normalmodus.
4. Wir empfehlen, den Betrieb des Melders ebenfalls im
Normalmodus zu testen, um zu gewährleisten, dass der Melder
den Alarmzustand auslöst und dass er auf der korrekten Zone
arbeitet (bei Mehrzonen-Alarmsystem). Weitere Informationen
finden Sie in der Installations- und Betriebsanleitung Ihres
Alarmsystems.
5. Nach Abschluss des Tests setzen Sie die rückseitige Abdeckung
des Melders zurück bzw. setzen Sie die Installation fort.
PIR-MELDER MONTIEREN (5)
1. Öffnen Sie die rückseitige Abdeckung des Melders. Benutzen
Sie die Abdeckung als Schablone, um die Befestigungslöcher
zu bohren (5a).
2. Montieren Sie die rückseitige Abdeckung mit den mitgelieferten
Schrauben und Dübeln an der Wand. Überdrehen Sie die
Befestigungsschrauben nicht, damit sich das Gerätegehäuse
nicht verzieht.
3. Setzen Sie das Gerät auf die rückseitige Abdeckung und setzen
Sie die Schraube unten im PIR-Melder zurück. Überdrehen Sie
die Befestigungsschraube nicht, damit sich das Gerätegehäuse
nicht verzieht.
4. Der Melder kann flach auf einer Wand oder in einer
Zimmerecke montiert werden. Wählen Sie einen geeigneten
Montageort (5b).
BETRIEB IM NORMALMODUS
Im Normalmodus arbeitet der PIR-Melder wie folgt:
1. Bei Sabotage erfolgt eine Meldung des PIR-Melders an die
Alarmzentrale. Zur Einsparung von Batteriekapazität ist die
Höchstzahl der Übertragungen auf 7 innerhalb von 2 Minuten
begrenzt. Dann erfolgt die nächste Übertragung erst wieder
nach 2 Minuten.
2. Ist der PIR-Melder einmal ausgelöst, so wird er zur Einsparung
von Batteriekapazität für die nächsten 5 Sekunden nicht
ausgelöst. Der PIR-Melder hat eine Selbsttestfunktion und
überträgt ein Überwachungssignal alle 50 Minuten an die
Alarmzentrale. Das Sabotage- oder Batteriekapazitätssignal
wird zusammen mit diesem Signal übertragen.
BATTERIESTATUS ERKENNEN (nur höherwertige Systeme)
1. Während der Übertragung des Überwachungssignals des PIRMelders an die Alarmzentrale alle 50 Minuten wird der Status
der Batterie ebenfalls übertragen.
2. Erkennt der PIR-Melder Sabotage oder Bewegung, so wird der
Status der Batterie ebenfalls übertragen.
3. Bei geringer Batteriekapazität blinkt die LED bei jeder
Auslösung des PIR-Melders für 1 Sekunde. In diesem Fall muss
die Batterie des PIR-Melders kurzfristig ausgetauscht werden.
Hinweis: Im TESTMODUS blinkt die LED ebenfalls bei
Auslösung des PIR-Melders. Unterscheidung zwischen den
beiden Bedingungen: Im Testmodus blinkt die LED für 0,5
Sekunden, bei geringer Batteriekapazität für 1 Sekunde.
4. Bei geringer Batteriekapazität hält der Melder den niedrigen
Batteriestatus und misst aus Energiespargründen die
Batteriekapazität nicht mehr. Der Status geringe
Batteriekapazität ändert sich nicht mehr, bis die Batterie
ausgetauscht und der PIR-Melder wieder neu eingeschaltet
wird.
UNEMPFINDLICHKEIT FÜR HAUSTIERE (6)
Dieses Gerät ist mit einem Unempfindlichkeitsmechanismus für
Haustiere ausgestattet, sodass kleine Tiere bzw. Haustiere den
Melder nicht auslösen und somit keinen Fehlalarm verursachen.
Wie in der Abbildung dargestellt, ist eine Person größer und löst
den PIR-Melder aus, wenn sie sich in den gesicherten Bereich
begibt. Auf der anderen Seite sind Haustiere klein genug, um
keinen Alarm auszulösen. Die Größe/Länge des Haustieres darf
allerdings 60 cm/90 cm nicht übersteigen, um den Melder nicht
auszulösen.
HINWEIS: Dieser Mechanismus arbeitet nur für ein Haustier.