Manual R2000-43-E Release: 1.03 © Elotech GmbH Page 23/24
XV. Operating Level, Option: only inputs zones d1 and d2
Display Display
"Process" „Zone“
input d1 d1 Display 1: 0...10 Vdc, corresp. the progr. range (ex works: 0...100)
input d1 d2 Display 2: 0...10 Vdc, corresp. the progr. range (ex works: 0...100)
XVI. Technical Data
Input RTD, Pt 100 (DIN): 2 - or 3 - wire connection possible.
Built-in protection against sensor breakage and short circuit.
Max. permissible line resistance by 3-wire connection: 80 Ohms
Sensor current: < 1 mA
Calibration accuracy: < 0,2 %
Linear error: < 0,2 %
Influence of the ambient temperature: < 0,01 % / K
Input Thermocouple: Built-in internal compensation point and protection against sensor breakage
and incorrect polarity.
Re-calibration not required for a line resistance of up to 50 Ohms.
Calibration accuracy: < 0,25%
Analog inputs (Option): 0 ... 10 V DC (Display range programmable)
Setpoint selection: Ext. potential-free contact, switching voltage appr. 24 V DC, max. 1 mA.
Selection between SP1 and SP2 valid for all zones.
Control outputs OUT 1 ... OUT 8: Bist. voltage signal, 0/18 V DC, max. 10 mA, short-circuit proof
or Relay, max. 250 VAC, max. 3 A (cos-phi = 1)
Alarm outputs A1 and A2: Relay, max. 250 VAC, max. 3 A (cos-phi = 1)
7-Segment-Display: Process: 10 mm red, Set: 10 mm red
Data protection: EAROM
CE-Mark Tested according to 2004/108/EC; EN 61326-1; industrial areas
Electr. safety: EN 61010-1
Power supply: Standard: 230 V AC, ± 10 %, 48...62 Hz, appr. 10VA
Connections: Screw terminals, Protection mode IP 20 (DIN 40050), Insulation class C
Permissible operating conditions: Operating temperature: 0...50 °C / 32...122 °F
Storage temperature: -30...70 °C / -22...158 °F
Climate class: KWF DIN 40040;
equivalent to annual average max. 75 % rel. humidity, no condensation
Casing: Format: 96 x 96 mm (DIN 43700), installation depth 122 mm
Panel cutout: 92 +0,5 mm x 92 +0,5 mm
Material: Noryl, self-extinguishing, non-drip, UL 94-V1
Protection mode: IP 20 (DIN 40050), IP 50 front side
Weight: app. 800 g
Heater current monitoring:
Current transformer 1:1000: Passive through current transformer with snap-in attachment for DIN rail
(Type M2000) mounting (EN 50022, 35mm).
Connections to the controller: 2 x 6,3mm flat connectors.
Heater current detection and
indication range: 0...max. 60,0A. Single-phase operation.
0...max. 99,9 A. Three-phase operation.
The sum of the current of all three phases of one controller zone will be monitored.
Variations of the power supply voltage have to be considered when the
the alarm values are programmed.
Current detection interval time programmable (1...60 sec.).
This is the time between the measuring of two successive controller zones.
Alarm delay time programmable. It depends upon the current detection interval time and the number of the
connected temperature zones (min. 8 sec.).
Subject to technical improvments!