Elnur RKS6L, RKS8L, RKS4L, RKS14L, RKS12L User Manual

...
THERMAL RADIATORS
RKS4Hi RKS4L RKS6Hi RKS6L
RKS8Hi RKS8L RKS10Hi RKS10L RKS12Hi RKS12L RKS14Hi RKS14L
INSTALLATION INSTRUCTIONS AND USER GUIDE
INSTALLATION INSTRUCTIONS AND USER GUIDE
Shelf
Closest object to the right end
Mínimum 25cm Control panel side
Mínimum 10cm
Closest
object to
the left
end
Mínimum
15cm
- The studs and screws to attach the supports are in the accessories bag.
- Hang the unit on the hooks of the brackets.
- By turning the screw the metallic square will
go downwards, retaining the heater. Repeat this on the other bracket.
Mark the fixing points on the wall using a pencil through the two fixing holes in the square brackets and perform corresponding bores.
Position and fix the brackets at the correct distance from the floor. It is possible to use the radiator as measuring unit by positioning it on two polyester package elements and placing two supports above as indicated on the figure:
Mínimum 15cm
1. - WARNING Please read these instructions before installing or using this appliance for the first time.
The warranty of the heater will not cover any damage caused by non observance of any of these instructions. This guide must be kept and given to any new owner. Any reinstallation should be carried out by trained personnel. The use of these heaters is forbidden in any area where there is a presence of gases, explosives or inflammable objects. DO NOT USE THIS HEATER TO DRY CLOTHES. The surfaces of this heater can be hot, so children should not be left unsupervised in the vicinity of the heater. Neither the connecting cable nor any other object must come into contact with the hot unit. Please check that the voltage in the rating label fits the power supply. Do not cover this heater at any time. The air outlet at the top of the thermal radiator and the air inlet at the bottom are provided to ensure the most efficient operation of the appliance.
They also protect the heater from overheating; therefore, it is essential that at no time are they covered.
This heater should be switched off at the isolating switch before any repair work is carried out. The thermal radiator should not be installed just below an electrical socket. The appliance must be installed in such a way that it is impossible for anyone using a bath or shower, to touch the controls. The installation must be carried out in accordance with the current electrical regulations in your country. The heater is fitted with a flexible cable size 3 x 1.00 mm2 for electrical connection. It may be used to connect the heater to the fixed wiring of the
premised through a suitable connection box positioned adjacent to the heater.
The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3 mm. If the flexible power cable for this unit is damaged, it may only be replaced by a repair workshop recognised by the manufacturer, as special tools
are necessary.
All models are supplied with an electrical interrupt cut-out. This will switch off the heater if, for any reason, it overheats. Should the cut-out
operate, turn the heater off and remove the cause for the overheating. The cut-out will be reset automatically.
The presence of air particles of smoke, dust and other pollutants could, in time, discolour the walls and surfaces around the heater.
2. - INSTALLATION INSTRUCTIONS
- Open the package and check that it is the correct model and it is in good condition.
- To obtain optimum performances it is necessary to maintain a minimum clearance of 15 cm between the radiator and any inflammable material as furniture, curtains etc.
- The rest of clearances required to maintain are indicated on the following figure:
2
ON
ON
Key “+”:
Press the key to increase the COMFORT set point temperature.
Key “-”:
Press the key to decrease COMFORT set point temperature. .
ON/OFF key:
Push the button to switch on/off the heater. Also you may lock/unlock the keyboard by maintaining it for several seconds.
OPERATION MODE KEY:
Press the key to select operation mode:
- permanent COMFORT,
- permanent
ECONOMICAL,
- permanent FROST
PROTECTION
- AUTOMATIC modes.
Example of the heater permanent COMFORT mode,
Set point temperature is 20.5ºC, showing ON output
condition.
The heater is OFF.
Main switch. All models are equipped with one switch on the back surface allowing the heater disconnection.
3. - USING THE THERMAL RADIATOR
MODELS RKSHi
LCD DISPLAY: LCD display shows the information related to the heater operation.
ADJUSTMENT OF THE SET POINT TEMPERATURE
COMFORT set point temperature may be adjusted from 7ºC to 30ºC in 0.5ºC steps.
Pressing the keys “+” or “–” the set point temperature is increased/reduced respectively. After three seconds if no other key is pushed the
selected value is stored in memory. The set point temperature in ECONOMIC mode is the COMFORT setting temperature reduced by 3.5ºC. The setting temperature in FROST-PROTECTION mode is 7ºC and it is constant.
CORRECTION OF TEMPERATURE MEASURES
If there is a difference between temperature values on an external thermometer and the temperature displayed by the unit, it is possible to change the sensor settings in order to balance the difference (-5ºC to +5ºC, in 0.5ºC steps).
In order to make changes hold the mod.key for more than five seconds and after that with buttons “+”
or “–” increase or decrease the correction to 0.5ºC respectively. Press the mod. key to store the
correction in memory and proceed with the next setting.
3
ONONON
>7 sec.
PERMANENT COMFORT mode. Push the key “+” or “–”if it is
required to modify comfort set point temperature.
PERMANENT ECONOMICAL
mode. The set point temperature is
reduced by 3.5ºC.
PERMANENT
FROST-PROTECTION mode.
The set point temperature is
7ºC and it is constant.
AUTOMATIC mode. In this mode programs from the input command cable (pilot wire) are performed.
BLUE BACKLIGHT
Pressing any key the display will illuminate with a soft blue color. After certain time if no other keys are pushed the display backlight will turn off. It is also possible to adjust the display backlight time.
Hold the mod. key during five seconds. After the correction, (if required) of the thermostat (see previous paragraph), a value from 0 to 90 seconds will be displayed. It may be modified in 15 seconds steps by “+” and “–” keys. If 0 value is selected, the display backlight will be off
permanently. To store, press the mod.key.
OPERATION MODES By the “mod. key different functions or operation modes may be selected.
KEYBOARD LOCK
In every operation mode it is possible to lock the keyboard by holding the ON/OFFkey for more than 7 seconds.
When the keyboard is locked, if any button is pressed, the display will show Lomessage and the unit will
not respond.
To unlock the keyboard press the ON/OFF” button for more than 7 seconds.
OPERATION WITH A PILOT WIRE PROGRAMMER.
It is possible to control the heater operation from a remote pilot wire programmer in AUTOMATIC mode. Pilot wire programmer orders for OFF and FROST PROTECTION are prior and independent from the operation mode selected in the heater.
OPERATION WITH A PROGRAMMER WITH POWER LINE CARRIER OR A LOAD-CONTROLER WITH POWER LINE CARRIER.
In AUTOMATIC mode, it is possible to control the heater operation from a programmer with PLC (Power Line Carrier) or from a load-controler with PLC.
TO ASSOCIATE the heater, switch the PLC programmer or the PLC load-controller to the “association” mode (see corresponding manual). Press the mod.button for more than five seconds and after that press the mod.button twice, the display will show “CP”, Keep the mod.button pressed. The message “CP” will start blinking. Release the mod.button and press it again.
The display will show “En. To store, press the “mod.”key.
TO DISASSOCIATE the heater press the mod.button for more than five seconds and after that press the mod.button twice, the display will show “CP”. Keep the mod.button pressed for 60 seconds until the display will show “An”. To store, press the “mod.”key.
4
PROG
c
MODELS RKSL
These four keys perform different operations depending on the message of the LCD display. Press two central buttons at a time for several seconds to lock/unlock the keyboard.
ON/OFF key:
Press the key to switch from OFF to OPERATION
Operation mode key:
Press the key to select different operation modes or to set the system time.
Main switch. All the models are equipped with the switch on the back surface for general heater disconnection. After a long-term disconnection it is necessary to reset the unit system time.
OK
1 2 3 4 5 6 7
days of the week
CONNECT / DISCONNECT
Time Settings
To perform correct programming it is necessary to set the system time. To set the system time the unit should be in OFF position, with a symbol
on the display. Press the mod. key. Week days indication will start blinking.
With “+” or “–” keys select present day and press OKto store. Proceed to time settings. Set the hour with “+” or “–” keys and press OKto store. Repeat the operation to set minutes.
Press the ON/OFFkey to exit.
5
PROG
c
ON/OFF
c
AUTOMATIC INTERNAL PROGRAMMER MODE
PERMANENT COMFORT MODE
PERMANENT ECONOMICAL MODE
PERMANENT FROST PROTECTION MODE
AUTOMATIC REMOTE PROGRAMMER MODE
1 2 3 4 5 6 7
PROG
AUTO
c
0h 2 4 6 8 10 12 14 16 18 20 22 24
c
AUTO
c
c
When the unit is in OFF, symbol is displayed together with premises temperature value.
To switch on the unit to ON mode press the key: Last operation mode before the unit had been switched off
will be displayed. Press the same key to switch off the unit and pass to OFF. Apply preferably this form to switch off the unit instead of the main switch in order to avoid setting the system time constantly.
The heater may operate only in one of two conditions; ON or OFF.
OFF:
ON:
Different operation modes may be applied. To switch from one mode to another press the mod. key after no less than two seconds between each change.
6
cONc
c
OK
1 2 3 4 5 6 7
PROG
0h 2 4 6 8 10 12 14 16 18 20 22 24
1 2 3 4 5 6 7
PROG
AUTO
c
0h 2 4 6 8 10 12 14 16 18 20 22 24
PERMANENT COMFORT MODE
In permanent comfort mode the unit maintains constantly the set point temperature. It is possible to modify COMFORT set point temperature in 0,5ºC steps by pressing the
keys “+” or “–”. Temperature range is from 5 to 30ºC.
When the heater consumes power, ON message is displayed.
Pressing the “i” will momentarily display the premises temperature.
PERMANENT ECONOMICAL MODE
In economical mode the unit maintains all the time the ECONOMICAL set point temperature.
Originally the economical set point temperature is the comfort set point temperature reduced by 3.5ºC. See menu 1 of CONFIGURATION paragraph to modify the reduction or even to select economic set
point temperature. Pressing the “i”key displays momentarily the premises temperature.
PERMANENT FROST PROTECTION MODE
In permanent frost protection mode the unit will operate when the premises temperature decreases lower than 7ºC.
In this mode pressing the “i” key displays momentarily the premises temperature.
AUTOMATIC INTERNAL PROGRAMMER MODE
In this mode the unit performs commands of the internal programmer.
Programming
By default the program “Comfort fro 8h to 22h is applied for all days of the week.
To modify the program press the PROG key in this mode or in OFF mode. Select the temperature level for the first time interval of the day 1 by pressing one of the following keys:
Pressing displays two segments indicating COMFORT temperature.
Pressing display one segment indicating ECONOMICAL temperature.
Pressing does not display any segment, indicating FROST PROTECTION temperature. After programming all 24 intervals for the DAY 1, press “OK” to pass to the DAY 2 of the week and repeat
the procedure.
Fast Programming To copy the complete program from one day to another hold the “OK” key for 3 seconds.
7
OK
AUTO
c
1 2 3 4 5 6 7
PROG
AUTO
c
0h 2 4 6 8 10 12 14 16 18 20 22 24
OK
SAND GLASS KEY Press the key to adjust the specified temperature for
certain determined time. By keys“+” or “–” adjust the set point
temperature and store by pressing the OK.
Adjust the time required by keys“+” or “–” and
press OK to store.
ABSENCE KEY Press the key to switch on the Frost Protection
mode from 1 day to 365 days. Adjust the amount of absence days by keys “+”
or “–”, and store with OK key. To disconnect the absence mode press again the
OK key.
INFO KEY Press the key to see the
premises temperature or set point temperature, according to configurations of MENU 5
PROG KEY Press the key to modify
the program
To go back to the previous settings press again the OK key.
AUTOMATIC REMOTE PROGRAMMER MODE
In this mode the unit follows commands from the remote control desk or remote programmer. If there aren’t any, the unit operates in permanent COMFORT mode.
KEYBOARD LOCK
En every operation mode it is possible to lock the keyboard pressing central “+” and “–” keys for several seconds.
With the keyboard locked pressing any key displays bloc message and the unit will not respond,
With the keyboard locked the unit may receive commands from the IR remote control. To unlock the keyboard press simultaneously central keys “+” and “–” for several seconds.
8
PROG
c
>10 sec.
OK
1 2 3 4 5 6 7
c
número de menú
OK
1 2 3 4 5 6 7
OK
1 2 3 4 5 6 7
c
c
CONFIGURATION
It is possible to configure various parameters of the unit.
In OFF mode press for 10 seconds ON/OFFkey to enter the first configuration menu. It is necessary to pass through five menus to exit the configuration. The
Menu number is displayed above in the right part of the display.
Menu 1: Adjusting the ECO set point temperature.
By default the Economic set point temperature value is equal to comfort temperature value reduced by 3,5ºC.
The reduction value may be modified from 0 a 10ºC in 0,5°C steps.
For this purpose modify the value with the keys “+” / “–” and press OKto store
and pass to the next setting.
ECO set point temperature value may be stored independently from the CONFORT temperature value.
To authorize ECO value modification press and hold the “+”key until it displays the
message "---- and store pressing OK.
In such a way when selecting the permanent economical mode it will be possible to assign any temperature with “+” or “–” key displayed at selection of
permanent economical mode.
Selection range will start from 4.5ºC to the comfort set point temperature.
Menu 2: Correction of temperature measures.
If there is a difference between an external thermometer indication and the temperature displayed by the unit, in menu 2 it is possible to influence on the sensor in order to balance the difference. (-5ºC to +5ºC,) in 0,1ºC steps.
To modify press the keys “+” or “–”, after press the OKkey and proceed with the
next setting.
9
OK
>5 sec.
1 2 3 4 5 6 7
OK
1 2 3 4 5 6 7
OK
1 2 3 4 5 6 7
- The thermal radiator does not heat.
Check the heater or the air inlets are not covered.
- The room does not reach the required temperature.
Check the selected temperature is in accordance with the desired temperature. Maybe the room needs more heating power.
- -9.9ºC” ó “99.9ºC” message is displayed
Sensor wrong connection. Contact the after sale service.
- “d2” or “d3” message is displayed
Sensor wrong connection. Contact the after sale service .
-“dEF” message is displayed
CPL connection trouble. Contact the after sale service.
- Time settings are lost
There was electric supply shortage or the unit had been disconnected by the main switch
- The keyboard does not respond
If the bloc message is displayed, the thermal radiator keyboard is locked. Hold two central keys
for several seconds to unlock the keyboard.
Menu 3: Configuration of CPL
This menu allows associating the unit to the remote CPL programmer connected to the same power grid.
In menu 3 press the “+”for 5 seconds. CPL message will start blinking. Switch the CPL programmer, remote control desk to the “association” mode (see
corresponding manual). Press shortly the “+”key. EnrEmessage displays on the screen and then "CPL" message confirming the association.
Press OK key to proceed with the following setting.
Menu 4: Backlight time settings
Adjustable backlight is available from 0 to 225 seconds in 15 seconds steps (90 seconds by default).
To modify press “+” or “–”, keys, then press the OK to store and proceed with the next setting.
Menu 5: Selection of temperature display in AUTO operation mode.
1 = Permanent display of the premises temperature. 0 = Permanent display of the set point temperature.
To modify press “+” or “–”, keys, then press the OK to store and exit the configuration mode.
4. - CLEANING AND MAINTENANCE
The radiators do not precise any special maintenance providing thermal comfort during large periods. Clean dust with a dry, soft cloth only when the unit is disconnected and cold. Do not use solvents or abrasive products for cleaning. After the heating season disconnect the radiator with the switch located on the back surface of the radiator. This thermal radiator has been manufactured under an assured quality system using environment friendly processes. Please take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right way.
5. - TROUBLESHOOTING
10
Model
RKS4Hi
RKS6Hi
RKS8Hi
RKS10Hi
RKS12Hi
RKS14Hi
RKS4L
RKS6L
RKS8L
RKS10L
RKS12L
RKS14L
ELEMENTS
4 6 8
10
12
14 4 6 8 10
12
14
LENGTH (cm)
41.5
57.5
73.5
89.5
105.5
121.5
41.5
57.5
73.5
89.5
105.5
121.5
WIDTH(cm)
10 PLUS 2.5 cm separation from the wall
HEIGHT (cm)
58
WEIGHT
9kg
13kg
17kg
21kg
25kg
29kg
9kg
13kg
17kg
21kg
25kg
29kg
POWER
500W
750W
1000W
1250W
1600W
2000W
500W
750W
1000W
1250W
1600W
2000W
ISOLATION
CLASS II
VOLTAGE
220-240V~
Connect the black wire marked “Fil Pilote“ to the signal wire when available. Do not connect this wire to any EARTH lead. Connect “L” and “N” wires to a fix wall socket or to an appropriate plug WITHOUT EARTH.
RKS-Hi
RKS-L
SPECIFICATIONS
11
GB: WARNING: In order to avoid overheating do not cover the heater.
GB
handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. These instructions are only valid in the EU member states.
The symbol on the product or in its packaging indicates that this product may not be treated as household waste. Instead it shall be
www.elnur.es
by ELNUR s.a.
Pol. Ind. “El Nogal” c/ Villa Esther, 11
28110, ALGETE - Madrid
As a part of the policy of continuous product improvement Elnur S.A reserves the right to alter specifications without notice.