INT600/INT600S Internal Sounder
with Hi/Lo Feature
Note: This unit NOT suitable for external installation
EN50131-4: 2009 INT600 INT600S
Power Source Remote Self Powered
Security Grade 3 2
Environmental Class II II
F
EATURES
- 108dB(A) siren output
- Independent low volume E/E, Keypad output
- 12V dc voltage operation
- Polycarbonate cover and backplate
- 2 way tamper protection: cover, rear
- Volt Free Tamper Connection
- Hold-off supply failure detection
- Selectable sound auto cut-off timer
- Full SAB using internal battery (INT600S)
O
PERATION
The INT600 sounder is used for notification of an alarm condition and entry/exit tone as generated within
an intruder, hold-up or other alarm system. In response to appropriate commands from the control panel,
the INT600 will emit a high intensity sound for alarm and an adjustable low level tone for
entry/exit/keypad.
The INT600 will detect any attempt to gain unauthorised access to the sounder by removal of the cover, or
any attempt to remove it away from its mounting surface. This will generate a tamper signal which is
normally fed back to the alarm control panel
The INT600 is classified as an internal remote powered sounder and is powered via an external power
source.
The INT600S is classified as an internal self powered sounder and has an on-board battery which is
recharged via the external power source. This battery is used to operate the sounder if the external power
to the sounder is removed.
F
UNCTIONAL INFORMATION
T
AMPER CIRCUIT
Volt free tamper terminals ‘TS & TR’ open when front or rear tamper switch is open, or on loss of H+ or H-.
Elmdene International Ltd
Tel: +44(0)23 9269 6638
3 Keel Close, Interchange Park, Fax: +44(0)23 9266 0483
Portsmouth, Hampshire, PO3 5QD, UK
Web: www.elmdene.co.uk
![](/html/d4/d4ad/d4adc2f2814a0333329bd283f6070fe111e0f650eff986b7419d281bb115d318/bg2.png)
2
Technical Support: +44(0)23 9269 6638 (option 3) PAK200035_07A Oct 2014 ©2014 ELMDENE INTERNATIONAL LTD
JP1: Cut-off timer for alarm (R-)
Link = no cut-off (default)
No link = sounder cut-off after 15 minutes
VR1: Volume control for entry/exit/keypad low level tone (M-)
Figure 1. Connections and Timer Selection Jumper
With the cut-off timer link NOT fitted, the INT600(S) sounder will automatically stop sounding after 15
minutes, irrespective of the status of the sound trigger (R-) input.
SAB M
ODE
(INT600S O
NLY
)
SAB mode is enabled if the internal battery is connected, the unit will then self-activate if the tamper is
activated or the supply cut.
C
ONNECTIONS
R- Negative siren trigger for alarm. Apply 0V to activate sounder
M- Negative low volume trigger for entry/exit/keypad. Apply 0V to activate.
ST- Not applicable.
H+ Permanent positive hold-off supply, +12Vdc nominal
H- Permanent negative hold-off supply
TR Volt free tamper connection
TS Volt free tamper connection
BT- SAB Battery negative
BT+ SAB Battery positive
C
OMMISSIONING
1) Remove cover.
2) Offer backplate to desired position on
mounting surface and drill holes to match
chosen fixing centres.
3) Fix backplate to mounting surface using
appropriate fixings for the mounting surface.
4) Set the required Cut-off Timer using JP1.
5) Loop the connection cable three times through the supplied ferrite as shown.
6) Connect +12V dc and 0V supply from the control panel to H+ and H- respectively.
7) Connect R- to Ring or Bell output of the control panel.
8) Connect TS to H- and TR to tamper return of panel for 0V tamper return, or use TS & TR as volt free
contacts without link between TS & H-.
9) If low output tone facility is used, connect M- to control panel ‘keypad follow’ or a programmable
output.
10) For SAB facility (INT600S only) connect the battery wires to BT+ and BT-, ensuring correct polarity.
NOTE: The unit will sound until the cover is replaced.
S
OUND CUT-OFF TIMER
ST- M- R- H+ H- TR TS BT+ BT-