13.8V dc Switch Mode Power Supply with Optional Fused Outputs
G1380xN-y-s
F
EATURES
High efficiency cost effective power supply ideal for use in Intruder, Access Control and General Security applications. Featuring a regulated 13.8Vdc output supplying continuous full rated current to load and up to an additional 0.5A for charging a standby battery. The universal mains input voltage enables the power supply to be used across a wide geographical area. The highly efficient switch mode design ensures low operating costs, generates less heat and with a small physical size increases the room available for additional PCBs or cables. The modular construction simplifies maintenance. An optional integrated output module allows multiple circuits to be individually fused*.
Continuous full rated current to load
Additional 0.5A to charge standby battery
Universal mains input voltage 90-264Vac
High efficiency electronics for reduced running costs and lower operating temperatures
Installer safe design with all high voltage electronics fully shrouded
Modular construction for ease of maintenance and installation
Full electronic short circuit and overload protection on load output under mains operation
Mains transient protection circuit
Lid opening tamper detection
Green Mains present LED
Red Fault LED*
Individually Fused Outputs*
* Dependent upon model.
C
OMPLIANCE
This power supply unit meets the essential requirements of the following European Directives: Low Voltage 2014/35/EU EMC 2014/30/EU WEEE 2012/19/EU RoHs2 2011/65/EC
S
PECIFICATION (INPUT
)
Voltage (rated) 100-240Vac Voltage (operating) 90-264Vac Frequency 50-60Hz Max current See Model Specification Table overleaf Mains Input Fuse See Model Specification Table overleaf Max standby Power 0.5W (No load and No battery connected)
Elmdene International Ltd
Tel: +44(0)23 9269 6638
3 Keel Close, Interchange Park, Fax: +44(0)23 9266 0483 Portsmouth, Hampshire, PO3 5QD, UK
Web: www.elmdene.co.uk
2
Technical Support: +44(0)23 9269 6638 (option 3) PAK200500_03C Dec 2016 ©2016 ELMDENE INTERNATIONAL LTD
S
PECIFICATION (OUTPUT
)
Voltage 13.4 – 14.2Vdc (13.8Vdc nominal) on mains power
10.0 – 12.3Vdc on battery standby Max load current See Model Specification Table overleaf Ripple 150 mV pk-pk max Load output Fuse See Model Specification Table overleaf Overload Electronic shutdown until overload or short circuit removed
(under mains power only)
S
TANDBY BATTERY
Battery Type 12V Valve Regulated Lead Acid Battery Capacity See below under enclosure size.
L
OCAL INDICATORS
MAINS LED (Green) Mains present FAULT LED (Red)*
Fault present: Output fuse fail
*
Not 4A or 5A
S
IGNALLING OUTPUTS
Lid Tamper N/O volt free contact (See Table for rating).
Note: Contact open when lid opened by normal means (TAMPER ACTIVE condition).
F
USED OUTPUTS (OPTIONAL
)
Model G1380xN-s G1380xN-2-s G1380xN-4-s G1380xN-8-s No. of fused outputs
1 2 4 8
Fuse Value See table
overleaf
2 x (max load
current / 2)
4 x (max load
current / 4)
8 x (max load
current / 8)
M
ECHANICAL
Model G1380xN-y-A G1380xN-y-B G1380xN-y-C G1380xN-y-F
Enclosure Dimensions
w x h x d (mm) [external]
230 x 200 x 80 355 x 330 x 80 330 x 275 x 80 380 x 230 x 75
Battery Capacity 1 x NP7 (8Ah) 1 x NP17 (18Ah) 1 x NP17 (18Ah) 1 x NP7 (8Ah)
Weight (kg) (Excluding Battery)
1, 1.5, 2, 3A 1, 2, 3A 4, 5A 1, 2, 3A 4, 5A 1, 2, 3A
2.0 3.9 4.3 3.3 3.7 3.5
E
NVIRONMENTAL
Temperature – Operating -10 to +40°C (operating) 75% RH non-condensing Temperature - Storage -20 to +80°C (storage)
3
Technical Support: +44(0)23 9269 6638 (option 3) PAK200500_03C Dec 2016 ©2016 ELMDENE INTERNATIONAL LTD
C
ONNECTIONS
+LOAD +ve voltage O/P to load equipment
-LOAD -ve voltage O/P to load equipment +BATT Red lead to standby battery
-BATT Black lead to standby battery Tamper x 2 Tamper voltfree contact
I
NSTALLATION INSTRUCTIONS
This unit is only suitable for installation as permanently connected equipment. The PSU is NOT SUITABLE for external installation. EQUIPMENT MUST BE EARTHED. Before installation, ensure
that external disconnect device is OFF. The PSU should be installed via a 3A fused spur according to all relevant safety regulations applicable to the application.
G1380xN-s (1A, 1.5A, 2A & 3A) G1380xN-s (4A & 5A)
Mounting
1) Mount securely in correct orientation allowing minimum clearance – see diagram.
2) Route mains and low voltage output cables via different knockouts and/or cable entry holes.
3) Use bushes and cable glands rated to UL94 HB minimum.
Mains Power Up
4) Attach correctly rated mains cable (minimum 0.5mm2 [3A], 300/500Vac) and fasten using cable ties.
5) Apply mains power. Check for 13.8Vdc on load outputs. Check green Mains LED is on.
6) Disconnect mains power.
Load Output
7) Attach correctly rated load cable and fasten using cable ties. Note polarity.
8) Apply mains power. Check green Mains LED is on.
9) NOTE: Red LED may be illuminated (dependent upon model) to indicate that no battery has been
connected. This is normal.
10) Verify load is operating correctly.
11) Disconnect mains power.
Standby Battery – NOTE: Ensure batteries being fitted to this unit are in good condition
12) Where not integral to PSU PCB, attach supplied battery cables to terminal block and battery.
NOTE: ensure correct polarity of battery connections: +ve use red lead, -ve use black lead.
13) Apply mains power. Check green Mains LED is on.
14) Check there is no fault indication on Red LED (dependent on model).
15) Disconnect mains power. Check that the batteries continue to supply voltage and current to the load.
The Green LED should be off. NOTE: Batteries must have sufficient charge to supply the load
16) Reconnect mains power. Green LED should be on.
17) Remove Load fuse and check red Fault LED is on (dependent on model).
18) Replace Load fuse. Check red Fault LED is off (dependent on model).
4
Technical Support: +44(0)23 9269 6638 (option 3) PAK200500_03C Dec 2016 ©2016 ELMDENE INTERNATIONAL LTD
Tamper
19) Check that the tamper spring makes good contact with box lid when closed. Check that the tamper
switch is:
- closed when the lid is closed and the lid screw is fitted
- open when the lid is open.
20) Close cover and secure using fastening screw(s) provided.
M
ODEL SPECIFICATION TABLE
G13801N
G138015N
G13802N
G13803N
G13804N
G138
05N
Output Current
1A
1.5A 2A 3A 4A 5A
Battery Charge Current
0.5A 0.5A 0.5A 0.5A 0.5A 0.5A
Mains LED
Fault LED
√ √ √ √
X X
Max Mains Input
Current (at 90Vac)
0.8A 1.0A 1.0A 1.2A 1.8A 2.0A
Mains Input Fuse
T2.0A
T2.0A
T2.0A
T2.0A
T3.15A
T3.15A
Output Fuse**
F1.0A
F1.6A
F2.0A
F3.15A
F4.0A
F5.0A
Tamper Rating
0.05A
24Vdc
0.05A
24Vdc
0.05A
24Vdc
0.05A
24Vdc
0.05A
24Vdc
0.05A
24Vdc
** Module Fuse
O
PERATING INSTRUCTIONS
This unit is intended for use by Service Personnel only - There are NO USER SERVICEABLE parts inside. The green Mains LED will be illuminated whilst the mains supply is present. In the event of a fault condition, the red Fault LED will be illuminated (dependent on model).
M
AINTENANCE
There is no regular maintenance required of the PSU other than periodic testing and replacement of the standby battery. Reference should be made to the battery manufacturer’s documentation to determine
typical/expected battery life with a view to periodic replacement of the battery.
If the output of the PSU fails the cause of the failure should be investigated e.g. short circuit load. The fault should be rectified before restoring power to the PSU. The fuses may need to be replaced. Ensure the correct fuse rating and type is used.
CAUTION
Risk of explosion if battery is replaced by an incorrect type. Dispose of used
batteries according to the battery manufacturer’s instructions and all local
and national regulations.