Elk products ELK-MM220 User Manual

Magic Module™Series
ELK-MM220 Module, 2 Input, 2 Output, Programmable ELK-MM443 Module, 4 Input, 4 Output, Programmable ELK-MV480 Voice Module, 400 Recordable Channels ELK-MK400 Starter Kit, Includes ELK-MM443 & ELK-MB485 ELK-MK485 Programmers Kit,ELK-MB485, Cables, Software ELK-MK420 iButton™ Access Kit w/ MM443, MA100, MA101 ELK-MA100 ELK-MA101 iButton "Touchkeys", 10 pcs w/keyring holders ELK-MA290 Proximity / Wiegand Data Interface to MM443 ELK-MC100 Clock / Calendar Module for ELK-MM443 ELK-MT100 Temperature Sensor Module for ELK-MM443 ELK-MK410 X-10® Transceiver Kit, Programmed ELK-MM443
Notice: It is recommended that the entire system be completely tested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail to perform as expected. Any system of any type may be compromised deliberately or may fail to operate as expected for a variety of reasons.
Elk Products, Inc. (“Manufacturer”) warrants to the original purchaser (the “Customer”) that the products it manufactures (“Product”) shall be free from defects in material and workmanship at time of shipment. Manufacturer’s obligations under this Limited Warranty shall be limited to repairing or replacing, at its option, free of charge, any product returned to Manufacturer freight prepaid. Manufacturer shall have no obligation under this Limited Warranty or otherwise if (1) the Product has been damaged by negligence, accident, mishandling, lightning or flood, or other Acts of God, (2) the Product has not been operated in accordance with its operating instructions, (3) the Product has been altered or repaired by anyone outside Manufacturer’s authorized facilities (4) adaptations or accessories have been made or attached to the Product which, in Manufacturer’s sole determination, have adversely affected its performance, safety or reliability. Products such as batteries and fused transformers have their own warranties, and are not included in this Limited Warranty. If a Product should malfunction or fail, contact Manufacturer or one of its authorized distributors for a Return Authorization (RA) number. Returned Products must include a complete description of the problem, along with the RA number clearly marked on outside of the package. Manufacturer will not be responsible for any unnecessary items included with any returned Product. THIS WARRANTY IS THE EXCLUSIVE WARRANTY FOR ANY PRODUCT. MANU­FACTURER SPECIFICALLY DISCLAIMS ANY AND ALL OTHER WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR OF MERCHANTABILITY. MANUFACTURER SHALL NOT BE LIABLE IN TORT, INCLUDING NEGLIGENCE OR STRICT LIABILITY, AND SHALL HAVE NO LIABILITY AT ALL FOR INJURY TO PERSONS OR PROP­ERTY. MANUFACTURER’S LIABILITY FOR FAILURE TO FULFILL ITS OBLIGATION UNDER THIS LIMITED WARRANTY OR ANY OTHER LIABILITY IN CONNECTION WITH A PRODUCT SHALL BE LIMITED TO THE AMOUNT OF THE PURCHASE PRICE RECEIVED BY MANUFACTURER FOR THE PRODUCT. THE REMEDIES STATED IN THIS LIMITED WARRANTY ARE THE CUSTOMER’S EXCLUSIVE REMEDIES AGAINST MANUFACTURER REGARDING ANY PRODUCT. UNDER NO CIRCUM­STANCES SHALL MANUFACTURER BE LIABLE FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING LOST PROFITS AND REV­ENUES, INCONVENIENCE OR INTERRUPTIONS IN OPERATIONS, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSSES OF ANY KIND. THESE LIMITATIONS AND DISCLAIMERS ARE NOT MADE BY MANUFACTURER WHERE PROHIBITED BY LAW. SOME STATES PROHIBIT LIMITATIONS OF WARRANTIES AND THE CUS­TOMER MAY HAVE ADDITIONAL RIGHTS IN THOSE STATES.
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interfer­ence in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
1) Reorient or relocate the receiving antenna. 2) Increase the separation between the equipment and receiver. 3) Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 4) Consult the dealer or an experienced radio/TV technician for help.
For more information contact your local Distributor or: ELK PRODUCTS,INC 828-397-4200 FAX 828-397-4415 http://www.elkproducts.com Email:info@elkproducts.com 06/03
iButton™ "Touchkey" Reader & Interface Pack
LIFETIME LIMITED WARRANTY
Magic Module Series
T wo Input, T wo Output
Programmable Module
ELK-MM220
4K Programmable Memory
APPLICATION:
The ELK-MM220 is an economical stand alone field programmable controller. It can be pro­grammed and used in a vast array of applications. It features two digital inputs, two form C relay outputs.
Magic Module Series
ELK-MM220
Two Input, Two Output
Programmable Module
Programs can be written and stored in non-volatile EEProm memory using the ELK-MK400 Develop­ment Kit. Typical Applications include: Program­mable Delay Timer, Alarm Memory, Single Zone Security System, Cross Zoning, Access Control,
Pulse Stretcher, Pulse Counter, Swinger Shutdown.
FEATURES:
Two Digital Inputs.
Two Form C Relay Outputs.
Four Timers, 1/10th Sec. - 255 hours.
Four General Purpose Counters, 0 - 255.
Non-volatile EEProm Memory.
LED Output Indicators.
SPECIFICATIONS:
Compact Enclosure Size: 4.5" x 3" x 1.2".
Operating Voltage: 9.6-15 Volts D.C.
Current Required: 70 mA.
Relays, 10 Amps @ 120VAC, 7 Amps @ 28VDC.
REQUIRES:
12 Volts D.C. Power Supply.
Optional:Starter Development Kit(ELK-MK400).
Features and Specifications subject to change without notice.
828-397-4200 Voice 828-397-4415 Fax http://www.elkproducts.com email: info@elkproducts.com
PO Box 100 • Hwy. 70W Hildebran, NC 28637 • USA
Instructions Printed On Inside
ELK-MM220 HOOK-UP DIRECTIONS
The ELK-MM220 has been factory programmed with a sample application as labeled on the unit, for other applications it must be reprogrammed before installation. The Program
Development Kit (ELK-MK400) is required to re-program the ELK-MM220 if desired. The Develop­ment Kit contains software and programming instructions needed to program the ELK-MM220. The program is written using the Elk Magic Module Software and debugged by using the ELK-MM443 Magic Module that is included in the development kit. The program is then download into the ELK­MM220 through a 5 conductor ribbon cable connected between the ELK-MM443 J1 connector and the ELK-MM220 J5 connector. Note: If using the Clock/Calendar Module(ELK-MC100), temporarily remove it to gain access to the ELK-MM443 J1 connector.
The ELK-MM220 has two digital inputs that switch from Low to High at approximately 2 Volts. Each input is jumper selectable at J1 & J2 for an onboard 2K input resistor either pulled up to +12 Volts, or pulled down to Ground. The ELK-MM220 has two form C relay outputs. Relay 2 is jumper selectable using J3 to switch the output through a transistor (100mA max). Placing J3 to the OUT position will disable Relay 2 and allow the Relay 2 COM terminal to be pulled to ground through a transistor when activated. This setting handles up to 100mA of current and is intended for applica­tions like flashing an LED. If more current or dry contacts are required then set J3 to IN and use the Relay 2 contacts, the transistor will be disabled.
Test the ELK-MM220 after downloading the program to ensure that it functions as desired. The ELK-MM220 can be reprogrammed multiple times.
Example Hookup: ELK-MM220 used as a Single Zone Security System
IN1 is a Momentary Key Sw itch, IN2 is a Normally Closed Burglar Loop, Relay 1 is the Alarm Output, Relay 2 is the Status LED
J3 is shown with
Relay 2 out of ciruit,
the COM terminal will
be pulled to ground
when output 2 is
activated
(100ma Max)
JUMPERS J1, J2 ,J3 are
located under cover
+12V position pulls up
IN1 or IN2 through a
2K resistor
GND position pulls
down IN1 or IN2
through a 2K resistor
+12 Volt DC Power Supply
ELK-624 Recommended
ELK-MM220
INPUT 1 SELECT
J1
+12V
GND
+
-
N.O. N.C.
-
+
MOMENTARY KEY SWITCH
INPUT 2 SELECT
J2
ALARM
SWITCHES
+
-
RELAY 2
+
12 VOLT
SIREN
(ELK-45)
OUT IN
RELAY 2RELAY 1
NO COM NCNO COM NCIN1 IN2 NEG+12V NEG
J3
-
LED
+
1K
J5
PROGRAMMER
RELAYS
ACTIVE
LEDS
D4 D3
1
OUTPUT
2
Input HookupTypes for IN1 and IN2
MM220
Normally Open
Closes to
Ground
INx
NEG
To Input Circuitry
2K
J1 or J2
GND
+12 VDC
GND
will see a Hi to Low
when Switch Closes
Input
Jumper
is set to
+12V
Normally Closed
Opens from
Ground
INx
NEG
To Input Circuitry
2K
J1 or J2
GND
+12 VDC
GND
MM220 will see a Low to Hi
when Switch Opens
Input Jumper is set to
+12V
+2 to 12 Volts DC
Normally Open
Closing Switch to
2 to 12 Volts DC
will trip this input
INx
NEG
To Input Circuitry
2K
J1 or J2
GND
+12 VDC
GND
MM220
will see a
Low to Hi
when Switch Closes
Input
Jumper is set to
GND
+2 to 12 Volts DC
Normally Closed
Opening switch will
trip this input
INx
NEG
To Input Circuitry
2K
J1 or J2
GND
+12 VDC
GND
MM220 will see a Hi to Low
when switch Opens
Input Jumper is set to
GND
Loading...