Elk products ELK-ML8 User Manual

* Try these other fine ELK products *
M1 Cross Platform Control
M1 (Std) Integrates Security, Lighting, Telephone, and
Energy Management. Powerful “Rules” based automation capabilities. Up to 208 Zones.
M1G (Gold) More powerful version of M1 with more
expansion and capabilities.
Magic Module Series
MM220 Magic Module, 2 Input, 2 Output, Programmable MM443 Magic Module, 4 Input, 4 Output, Programmable MM447 Automation Controller w/Voice,Caddx Interface MV480 Recordable Voice Module, 400 Channels MK400 Starter Kit, Includes MM443 & MK485 MK485 Programming Kit, MB485, Cables, Software MB485 Data Bus Interface, RS232 to RS485
Rust Free Sirens / Speakers
1RT Speaker & Stainless Steel Enclosure 150RT Siren & Stainless Steel Enclosure
Speakers & Sirens
44 Speaker, 30 W,8 Ohm Compact Horn 45 Siren, Compact Horn, 118db M120 Siren, Single Tone, 107db, Mini Horn SP15 Speaker, 15 watt, Small Horn SP30 Speaker, 30 watt, Horn SP35 Speaker, 20 watt, Interior SP40 Speaker, 40 watt, Horn SS15 Siren, Dual Tone, 110db, Horn SS30 Siren, Dual Tone, 120db, Horn SS36 Siren, Dual Tone, 105db, Interior
ECHO™ Sirens & Speakers
73 ECHO Speaker, 20 Watt, Interior 74 ECHO Dual Tone Siren, Interior 75 ECHO Voice Siren, Interior 870 ECHO Speaker, Self Amplified
Siren & Voice Drivers
100 High Performance Siren Driver 110 Voice Siren Driver, English & Spanish 120 Recordable Voice Module and Siren 124 Recordable Voice Module, 4 Channels
Surge Suppressors
950 Surge Suppressor, Phone & Power Line 951 Surge Suppressor, Phone - Single Line 955 Surge Suppressor, Phone - Dual Line
Relay Modules
912 Compact Relay,12 Vdc, SPDT 912B Heavy Duty Compact Relay,12/24 Vdc, SPDT 924 Sensitive Relay, 12/24 Vdc, DPDT 941 Alarm Output Director 960 Delay Timer Relay, 1 sec. to 60 min.
Power Products
1250 Battery, Lead Acid, 12v, 5Ah 1280 Battery, Lead Acid, 12v, 8Ah P112 12 Volts DC, 1 Amp Power Supply w/Enclosure P124 24 Volts DC, 800mA Power Supply w/Enclosure P1216 12 Volts DC, 1.5 Amp Power Supply P412 12 Volts DC, 4 Amp Power Supply P624 Power Supply & Battery Charger PD9 Power Distribution Module 965 Low Battery Cutoff and Power Switch TRG1640 Transformer, 16.5VAC @ 40 VA TRG2440 Transformer, 24VAC @ 40 VA
Accessories
129 Computer Sound Card Interface 800 Audio Amplifier, 10 Watts 900-2 “B” Connectors,Unfilled,500 pcs 902-2 “B” Connectors,Gel filled,500 pcs 980 Telephone Line Fault Monitor 999 Double Sided Tape SL1 Strobe Light, 4 colors available WK1 Wall Mount Kit for SL1 Strobes
For more information contact your local Distributor or: ELK PRODUCTS,INC 828-397-4200 FAX 828-397-4415
http://www.elkproducts.com Email: info@elkproducts.com
09/04
Magic Module Series
Link Interface To
Caddx NX Controls
ELK-ML8
APPLICATION:
The Link Interface (ELK-ML8) acts as a bridge between the data bus of a Caddx NX Control and a Magic Module (ELK-MM443). It allows shared use of the inputs, outputs, and system status for Lighting, Energy Savings, HVAC, General Automation, and Security applications.
Magic Module Series
ELK-ML8
Link Interface to
Caddx NX Controls
Accessory for the ELK Magic Module
FEATURES:
Fast and Easy Home Control and Automation
utilizing existing Security Sensors and System Status from a Caddx NX control¹.
Simple 2 Wire Hookup to the Control.
16 Preset Conditions Mapped and
Broadcasted Upon any Change.
On Demand Interrogation of 240 Conditions.
Real Time Clock & Calendar Event Functions
utilizing the Caddx NX built-in clock.
Small Size Conveniently Mounts inside Control.
Lifetime Limited Warranty, call for details.
SPECIFICATIONS:
Size: 4" x 2.75" (102mm x 70mm).
Operating Power Derived From the Magic Module
Power Source or the Caddx Control.
Operating Voltage: 9.6-15 Volts D.C.
Current Required: 30mA.
REQUIRED EQUIPMENT: (not included)
ELK Magic Module (ELK-MM443).
ELK Programming Kit (ELK-MK485).
Features and Specifications subject to change without notice.
828-397-4200 Voice 828-397-4415 Fax http://www.elkproducts.com email: info@elkproducts.com
PO Box 100 • Hwy. 70W Hildebran, NC 28637 • USA
Instructions Printed On Inside
The Link Interface (ELK-ML8) connects to the data bus of the Caddx NX Control¹ using only 2 wires. Data received from the control is mapped to 16 collection flags. Changes to these flags are broadcasted over the Magic Module data bus. In addition, 240 bits of data from the Control may be interrogated on demand by the Magic Module. In order to program the 16 collection flags or develop a Home Control or Automation application, a Magic Module Programmers Kit (ELK-MK485) is needed.
INSTALLATION
Step 1. Disconnect all power to the Caddx NX Security Control and the ELK Magic Module. Step 2. Mount the Link Interface using the enclosed self adhesive foam tape or two of the special NX enclosure slide rails. Step 3. Connect the Link Interface, Caddx NX Control, and Magic Module as per figure 1 below.
NOTE: Figure 1 shows the Magic Module components powered from the NX Control. Be certain that the maximum combined current draw including any keypads or auxiliary devices does not exceed the ratings published with the control. The Link Interface and one Magic Module draw 55mA idle or 185mA with all relays active. A Magic Voice Module will add an additional 70mA idle and up to 500mA when active with 3/4 volume setting. If you prefer (or need) to power the Magic Module from another source, leave off the Red +V wire from the keypad input to the ML8 and connect another DC power source to either the +12V and Neg terminals or J3 of the Magic Module. The Magic Module power receptacle J3 accepts a plug-in 12Vdc (center pin positive) power supply such as the ELK-P1216 (sold separately).
Step 4. After all wiring connections are complete apply power to the NX Security Control and Magic Module. Step 5. Use the Magic Module "Code Writer" or "Application Writer" software to setup the 16 collection flags and develop
the desired operation program. The Software includes a manual and on-line help screens.
LEDs XMIT = Blinks when information is being transmitted to or received from a Magic Module
RCV = Blinks when the NX Control is transmitting information to the Link Interface STATUS = Blinks slowly when the Control Keypad data bus is operational. PWR = On when the Link Interface is receiving Power.
¹ Works with most Caddx NX Controls except "E" series
D5
not used
DATANEG+V
SELECT X-10
2-WAY 1-WAY
JP10
RELAY 4
Mount the ELK-ML8
Interface Here
Or
Mount using Rails
Here
TO
CADDX
KEYPAD BUS
(3 WIRES)
POWER
J3
X-10 and DALLAS Interface
J5
RELAY 3
IN OUT
IN OUT
DATA NEG
+V
NEG B DATA A DATA +12 VOLTS
CADDX NX ALARM CONTROL BOARD
OPTIONAL
ELK-P1216
KP DATA KP COM KP POS
*
POWER
SUPPLY
* CADDX NX4/6/8 ALARM CO NT ROL
LINK INTERFACE ELK-ML8
JP1 MODE
AUX NORMAL
NEGB+12V A
RCV
XMIT
J1
BLACK YELLOW
See Step 3 for +V
Optional Hookup
* ELK-MM443 MA GIC MODULE
124816
J1
DATA BUS ADDRESS JUMPERS
SET TO ADDRESS 1
RED
GREEN
RS-485 BUS
(4 WIRES)
Leave in the
NORMAL
Position
PWRSTATUS
JP4JP3JP2JP1
BA
-
+
1-2
J2
4
3
-
K1
NOCOM NC
RELAY 1
K2
NOCOM NC
COMNCNO COM NC
NO
RELAY 2 RELAY 3
K3
RELAY 4
Items noted with * must be purchased separately
Figure 1. Typical Wiring Diagram
K4
See Step 3 for +V
Optional Hookup
* X-10
2 WAY
POWERLINE
INTERFACE
MODEL:PSC05
Required
only for
Applications
using X-10
Devices