Elk products ELK-980 User Manual

* Try these other fine ELK products *
MM443 Magic Module, 4 Input, 4 Output, Programmable MM447 Automation Controller w/Voice,Caddx Interface MV480 Recordable Voice Module, 400 Channels MKHOME1 Home Control Kit for Caddx NX Controls MK400 Starter Kit, Includes MM443 & MK485 MK485 Programming Kit, MB485, Cables, Software MK410 X-10® Transceiver Kit, Programmed MM443 MK420 MA100 MA101 iButton ‘Touchkeys’,10 pcs w/keyring holders MA290 Proximity / Wiegand Data Interface to MM443 MB485 Data Bus Interface, RS232 to RS485 MC100 Clock / Calendar Module for MM443 ML8 Link Interface to Caddx NX Controls MT100 Temperature Sensor Module for MM443 MM220 Magic Module, 2 Input, 2 Output, Programmable
1RT Speaker & Stainless Steel Enclosure 150RT Siren & Stainless Steel Enclosure 155RT Voice Siren in Stainless Steel Box
44 Speaker, 30 W,8 Ohm Compact Horn 45 Siren, Compact Horn, 118db 55 Voice Siren, Compact Horn M120 Siren, Single Tone, 107db, Mini Horn SP15 Speaker, 15 watt, Small Horn SP30 Speaker, 30 watt, Horn SP35 Speaker, 20 watt, Interior SP40 Speaker, 40 watt, Horn SS15 Siren, Dual Tone, 110db, Horn SS30 Siren, Dual Tone, 120db, Horn SS36 Siren, Dual Tone, 105db, Interior
73 ECHO Speaker, 20 Watt, Interior 74 ECHO Dual Tone Siren, Interior 75 ECHO Voice Siren, Interior 870 ECHO Speaker, Self Amplified
100 High Performance Siren Driver 110 Voice Siren Driver, English & Spanish 120 Recordable Voice Module and Siren 124 Recordable Voice Module, 4 Channels
950 Surge Suppressor, Phone & Power Line 951 Surge Suppressor, Phone - Single Line 955 Surge Suppressor, Phone - Dual Line
912 Compact Relay,12 Vdc, SPDT 912B Heavy Duty Compact Relay,12/24 Vdc, SPDT 924 Sensitive Relay, 12/24 Vdc, DPDT 941 Alarm Output Director 960 Delay Timer Relay, 1 sec. to 60 min.
1240 Battery, Lead Acid, 12v, 5Ah 1270 Battery, Lead Acid, 12v, 8Ah 12100 Battery, Lead Acid, 12v, 12Ah 12170 Battery, Lead Acid, 12v, 18Ah 12250 Battery, Lead Acid, 12v, 25Ah P112 12 Volts DC, 1 Amp Power Supply w/Enclosure P124 24 Volts DC, 800mA Power Supply w/Enclosure P1216 12 Volts DC, 1.5 Amp Power Supply P412 12 Volts DC, 4 Amp Power Supply P624 Power Supply & Battery Charger PD9 Power Distribution Module 965 Low Battery Cutoff and Power Switch TRG1640 Transformer, 16.5VAC @ 40 VA TRG2440 Transformer, 24VAC @ 40 VA
129 Computer Sound Card Interface 800 Audio Amplifier, 10 Watts 900-2 “B” Connectors,Unfilled,500 pcs 902-2 “B” Connectors,Gel filled,500 pcs 980 Telephone Line Fault Monitor 998 Warning Alarm System Decals 999 Double Sided Tape SL1 Strobe Light, 4 colors available WK1 Wall Mount Kit for SL1 Strobes
For more information contact your local Distributor or: ELK PRODUCTS,INC 828-397-4200 FAX 828-397-4415
http://www.elkproducts.com Email: info@elkproducts.com
01/03
Magic Module Series
iButton Access Kit w/ MM443, MA100, MA101 iButton ‘Touchkey’ Reader & Interface Pack
Rust Free Sirens / Speakers
Speakers & Sirens
ECHO™ Sirens & Speakers
Siren & Voice Drivers
Surge Suppressors
Relay Modules
Power Products
Accessories
Telephone Line
Fault Monitor
ELK-980
APPLICATION:
The ELK-980 triggers a relay output upon sens­ing a dead telephone line. Circuitry monitors phone line voltage as well as current in order to protect against false sensing. It installs easily between the incoming telephone block and the equipment using standard 8 conductor modular cables (not supplied).
Telephone Line
Fault Monitor
ELK-980
FEATURES:
Detects a Faulted Telephone Line.
Monitors Phone Line Voltage and Current.
Selectable Time Delay period on the relay.
Built-in LED displays Status / Fault Memory.
Unit is Powered by 12 or 24 Volts D.C.
Provides Form "C" Relay Output on Fault.
Dual RJ31/38X 8 Position Modular Jacks.
Lifetime Limited Warranty, call for details.
SPECIFICATIONS:
Operating Voltage: 12 or 24 Volts D.C.
Current Draw: 30mA.
Dimensions: 4.4" x 3.0" x 1.125".
Relay Contact Rating: 1A @ 250VAC.
Requires (2) 8 Pin Modular Cables
(not included).
This device complies with Part 68 of the FCC rules. FCC Reg. No. 5K6USA-25252-KX-N Ren No. 0.0B. It has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. See label on ELK-980 for Canadian DOC Certification Number.
Features and Specifications subject to change without notice.
828-397-4200 Voice 828-397-4415 Fax http://www.elkproducts.com email: info@elkproducts.com
PO Box 100 • Hwy. 70W Hildebran, NC 28637 • USA
Instructions Printed On Inside
INSTALLATION
1. Connect the ELK-980 to the incoming phone jack using a standard 8 wire full modular "male to male" phone cord (J2).
2. Connect the security equipment using a second 8 wire cord (J1). Depending on the equipment, this cord may be identical or
it may have a male plug on one end and spade terminals on the other end. (PHONE CORDS ARE NOT SUPPLIED)
3. Connect two (2) wires from the ELK-980 to 12 Volts D.C. To power from 24 VDC, move Jumper JP3 to the 24V position.
4. Connect two (2) wires from the relay output to the device that is to be activated when a dead phone line is detected. Option: Power and relay connections can be made using the four (4) extra wires in modular cord J1. This requires a cord
with a male plug on one end and spade terminal wires on the other. This is not possible if the security equipment requires a male plug ended cord. See FIGURES 1 and 2 below for details on the various jumper options and wiring configurations.
OPERATION
A typical on-hook phone line will measure around 48 volts. The voltage is lower during a call in process (off-hook), however the telephone instrument will then draw current on the line. The ELK-980 utilizes both telco voltage and current to properly detect a faulted line while reducing incidents of false detects. The ELK-980 considers the phone line to be faulted whenever the
line voltage falls below 3 volts and the line current draw is less than 18mA.
PHONE LINE OK - STATUS LED blinks once per second as line is tested. Relay energized, contacts COM and NC are closed. PHONE LINE FAULT - STATUS LED steady ON. Relay de-energized, contacts COM and NC are open, COM and NO are closed. FAULT MEMORY - Upon restoral of a phone line fault the LED remains predominantly ON and blinks OFF once every 3
seconds. To reset memory indication, momentarily short (for 2 seconds) the two small pins beside the STATUS LED. LED should return to 1 blink per second if phone line is OK.
FIGURE 1: USING SCREW TERMINALS AND WIRES FOR POWER AND RELAY
JUMPERS JP2 AND JP4 MUST BE SET AS SHOWN FOR THIS CONFIGURATION
JUMPER JP2: POWER HOOKUP
YES
NO
SET TO "NO" TO CONNECT POWER USING POS. & NEG. SCREW TERMINALS
JUMPER JP3: INPUT VOLTAGE
THE ELK-980 CAN BE POWERED FROM A 12V OR 24VDC POWER SUPPLY
24V
12V
JUMPER JP4: SUPERVISION HOOKUP ABC
SET JUMPER ON "B" THIS CREATES A CLOSED LOOP ON WIRES 2 & 7 OF J1
SECURITY/PHONE
EQUIPMENT
MALE PLUG MAY
BE REQUIRED WITH
SOME EQUIPMENT
TO J1
3 & 6 (NOT USED)
2 & 7 (OPTIONAL) PLUG TAMPER LOOP
AUX POWER
24HR N/C ALARM ZONE
RING
TIP
TELCO
+12V AUX POWER
R1 T1
NEGATIVE (GND)
ZONE INPUT ZONE (COM)
FIGURE 2: USING WIRES IN PHONE CORD J1 FOR POWER AND RELAY
JUMPERS JP2 AND JP4 MUST BE SET AS SHOWN FOR THIS CONFIGURATION
JUMPER JP2: POWER HOOKUP
YES
NO
SECURITY/PHONE
EQUIPMENT
TELCO
24HR N/C ALARM ZONE
AUX POWER
SET TO "YES" TO HOOKUP POWER USING WIRES 3 & 6 ON J1
RING
TIP
R1
T1 ZONE INPUT ZONE (COM)
NEGATIVE (GND)
+12V AUX POWER
WIRE WIRE NO. COLOR
BLACK3 YELLOW
6
ORANGE
2
BLUE
7
RED4 GREEN
5
SLATE
1
BROWN
8
CORD MAY BE
(MALE TO MALE) OR
(MALE TO SPADE)
WIRE WIRE NO. COLOR
4 RED 5 GREEN 1 SLATE 8 BROWN 7 BLUE 2 ORANGE 3 BLACK 6 YELLOW
MODULAR CABLE (MALE TO SPADE)
ELK-980
Telephone Line
Fault Module
YES
JP2
NO
8 PIN JACK
OUT
J1
J1
24V
JP3
8 PIN JACK
IN J2
STATUS
J2
JP5: MEMORY RESET MOMENTARILY SHORT TO RESET LINE FAULT
MEMORY
JUMPER JP3: INPUT VOLTAGE
THE ELK-980 CAN BE POWERED FROM A 12V OR 24VDC POWER SUPPLY
ELK-980
Telephone Line
Fault Module
JP2
YES
NO
8 PIN JACK
OUT
J1
J1
8 WIRE QTR.
REQUIRED
JP1
24V
JP3
8 PIN JACK
IN J2
STATUS
J2
JP5: MEMORY RESET MOMENTARILY SHORT TO RESET LINE FAULT
JP1
12V
K1
D7
RESET
JP4
12V
D7
RESET
MEMORY
A
JP4
5 MIN 30 SEC
JP5
24V 12V
A
BC
5 MIN 30 SEC
JP5
BC
N/O COM N/C
ALARM RELAY
POWER
NEG POS
8 WIRE FULL
MODULAR CABLE
(MALE TO MALE)
N/O COM N/C
ALARM RELAY
POWER
NEG POS
8 WIRE FULL
MODULAR CABLE
(MALE TO MALE)
JUMPER JP1: DELAY AFTER FAULT
SETS TIME DELAY BEFORE RELAY OPENS AFTER LINE FAULT
K1 RELAY IS ENERGIZED WHILE
PHONE LINE IS GOOD (CLOSED
CIRCUIT: COM TO NC)
(ELK-950 Recommended)
RJ31X JACK
R1
1
342
678
T1
R
5
T
JUMPER JP4: RELAY HOOKUP
A
B C
SET JUMPERS ON "A & C" TO CONNECT RELAY NC & COM USING WIRES 2 & 7 ON J1 (CLOSED CIRCUIT ONLY) RELAY OPENS ON FAULT
JUMPER JP1: DELAY AFTER FAULT
SETS TIME DELAY BEFORE RELAY OPENS AFTER LINE FAULT
THESE TERMINALS ARE NOT USED IN THIS CONFIGURATION
(ELK-950 Recommended)
RJ31X JACK
R1
1
342
678
T1
R
5
T
HOUSE
PHONES
HOUSE
PHONES
5 MIN 30 SEC
INCOMING
TELCO
LINE
5 MIN 30 SEC
INCOMING
TELCO
LINE