Elk products ELK-106055 User Manual

ENROLLING PROX CARDS AND FOBS
WITH M1 CONTROL
Each prox card/fob must be enrolled into a User Code location, using the same procedures that are used to add/change User Code PINs.
TM
UltraProx Weigand
Reader
1. On the Keypad, press the center ELK key.
2. Press 6 to jump directly to Menu 06 - Change User Codes OR Use the UP or DOWN arrow keys to scroll to the menu.
3. Press the RIGHT arrow key to select Menu 6. Enter a Master user code (PIN) to gain access to this menu.
4. Use the UP or DOWN arrow keys to scroll to the User Code location (001 to 099) where the Prox card/fob is to be enrolled. OR enter the three digit number, i.e., 050 for User 50.
5. Select CHG by pressing the RIGHT arrow key.
6. The keypad will display the existing 4 or 6 digit code that is programmed for this user along with any programmed name.
7. Place a new (not previously enrolled) prox card/fob near the UltraProx Weigand Reader. The nominal read range is approximately 3" from the front surface. The clam-shell type prox cards generally have a better read range than fobs.
8. If the keypad accepts the new prox card/fob, it will beep 3 times and display a 12 digit code, which is part of the ID stored in the card/fob. If the keypad rejects the prox card/fob, it will produce a low error tone and display:
Code Not Authorized, Redo The reject error may be caused by: A. The card or fob has already been enrolled (the M1 does not allow duplicate codes)
OR B. The facility code stored in the prox card/fob does not match the ELK facility code. The UltraProx Weigand Reader can only read cards/fobs which have the matching facility code.
9. After a prox card/fob has been enrolled into a user code location, its capabilities are set by the User Code Options found in Menu 02 of the M1 Installer Level Programming. The most common of these options are:
- Arm the M1 Control.
- Disarm the M1 Control.
- Access - Trip output to de-energize a lock ** ** The activation assignment for M1 Outputs
requires the Whenever/And/Then Rules programming of the Elk-RP Software.
The following example is a rule to activate Output 003 for 10 seconds when a valid prox card/fob (with Access Option enabled) is presented at Keypad 01. The output could be used to break or make power to a door strike.
WHENEVER Keypad 01 Access is Activated
THEN Turn On Output 003 for 10 seconds.
03/06
ELK-106055
The Elk UltraProx Weigand Reader is a compact, technically advanced external proximity reader with 26 bit Weigand output for use with most access controllers and the Elk M1 control family. It is ideal for higher security installations and as an alternative to remembering PIN codes.
UltraProx Weigand
Reader
ELK-106055
FEATURES:
Compatible with ELK M1 control family
Compatible with most access controllers
26-bit Weigand Output
Slimline waterproof housing with epoxy potted
electronics
User configurable inputs for the onboard buzzer
and green LED
Compatible with Clamshell Style (Credit Card
size) Proximity Cards (ELK-M1PRC)
Compatible with Keychain Style Proximity Fobs
(ELK-M1PRF)
Substitutes for User Code Pin Entry
SPECIFICATIONS:
Reader Format: 26 bit Weigand
Nominal Read Range: ~ 3"
Operating Voltage: 12 VDC
Current Draw: 50 mA.
Size: 1.9 W x 3.2" H x .9" D
Features or Specifications subject to change without notice.
CARDS AND FOBS (ordered separately)
ELK-M1PRC Prox Cards
Pack of 10, White clam shell style card
Size: 2 1/8" L x 3 3/8" H x 3/16" T
ELK-M1PRF Prox Fobs
Pack of 10, Black keyring fobs
Size: 2 1/8" L x 1 1/4" H x 1/4" T
828-397-4200 Voice 828-397-4415 Fax http://www.elkproducts.com email: info@elkproducts.com
PO Box 100 • Hwy. 70W Hildebran, NC 28637 • USA
Installation Instructions on Inside
INSTALLATION
The reader is designed for surface mounting adjacent to the door being controlled. The unit is fully sealed for indoor or outdoor use. Installation requires 2 mounting holes and a 0.3" cable hole.
WIRING
The wires should be terminated using appropriate "splice" connectors (not supplied). The piezo beeper and the green LED are installer configurable, requiriing a switched negative to activate. They can be wired as required to the controlling device.
VIOLET - Not Used BLUE - Buzzer Control (Negative "-" Input) BROWN - Green LED Control (Negative "-" Input) GREEN - Weigand Data 0 WHITE - Weigand Data 1 RED - Power Input +12VDC BLACK - Power Input -12VDC Negative SHIELD - Connected Internally to Negative
POWER SUPPLY
The Weigand Reader would normally be supplied power from the contol panel or controller to which it is connected. Read range may be greater with a linear (non-switch mode) power supply.
ENROLLING CARDS AND FOBS
For instructions on enrolling cards and fobs, refer to the installation manual for the controller the Weigand reader is connected to. Instructions for enrolling cards and fobs into an M1 controller can be found on the front of this installation sheet.
Connecting an ELK-106055 Ultraprox Weigand Reader to an ELK-M1KP Keypad
(Requires Purchase of ELK-WO35A Cable)
1. Turn Off the M1 Master Power Switch.
2. Using the W035A Cable Assembly, splice wires as indicated in Figure 1.
3. Remove the M1KP Keypad from its mounting plate, disconnect the 6 pin data bus cable, and place face down on a soft surface.
4. Locate the 5 pin male connector marked J2 (see Figure 2).
5. Plug the W035A cable into connector J2
6. Reconnect the 6 pin data bus cable to connector J1 and install the keypad onto its mounting plate.
7. Turn On the M1 Master Power Switch. Refer to the instructions for enrolling cards or fobs.
Figure 2
E LK-M1KP LC D Keypad
Back (Circuit) Side of Keypad
Six (6) conductor plug-in data bus cable
J1
Brown
Green
Black
Brown Wire Insulate (No Connection)
Figure 1
White
Red
ELK-WO35A Cable Assembly
(not incl uded)
Distance = 10 ft.
Red
White Black
Green
Violet
Brown
Shield
Maximum Wire
Blue
Insulate
}
(No Connection)
ELK-106055
UltraProx
Reader (26
bit Wiegand)
J2 Connector
To
Proximity
Reader
Loading...