Guide for using multiple UBEC controllers to control one valve
UBEC1, UBEC2, & UBEC3 with E1F & E2F actuated valves
Two UBEC1, UBEC2, or UBEC3 controllers can be used to operate one E1F or E2F actuated valve. One
controller will be the primary and the other controller will need to be programmed as a secondary. We have
part numbers set up for primary controllers that include harness length options for connection to the E1F & E2F
actuators. We have part numbers set up for UBEC1, UBEC2, or UBEC3 controllers that include secondary
harness length options for CAN connection to the primary controller. The primary controller will override the
secondary controller.
UBEC1 with E3F & E5F actuated valves
Two UBEC1 controllers can be used to operate one E3F or E5F actuated valve. The E3F or E5F actuator
controller will be the primary and the UBEC1’s will need to be programmed as a secondary. We have part
numbers set up for a UBEC1 that includes optional lengths for a secondary CAN harness that will reach the
E3F or E5F actuator. The same part number can be used to order a second UBEC1 controller with the CAN
harness length option needed to reach from it to the E3F or E5F actuator. A CAN connector kit (our p/n
37221000) will be needed to connect the CAN wires from the UBEC1 controllers and the E3F or E5F actuator.
This kit should be positioned within 3 feet of the E3F or E5F actuator. Programming code 340 will need to be
used to turn off the terminating resistor in the E3F or E5F actuator. In this system the UBEC1 controllers will be
secondary controllers and neither will be able to override the other.
UBEC2 & UBEC3 with E4F & E6F actuated valves
Two UBEC2 or UBEC3 controllers can be used to control one E4F or E6F actuated valve. The E4F or E6F
actuator controller will be the primary and the UBEC2’s or UBEC3’s will need to be programmed as a
secondary. The pressure sensor and flow sensor wire harnesses will be connected to the E4F or E6F actuator.
We have part numbers set up for UBEC2 or UBEC3 controllers that includes optional lengths for a secondary
CAN harness that will reach the E4F or E6F actuator. The same part number can be used to order a second
UBEC2 or UBEC3 controller with the CAN harness length option needed to reach from it to the E4F or E6F
actuator. A CAN connector kit (our p/n 37221000) will be needed to connect the CAN wires from the UBEC1
controllers and the E4F or E6F actuator. This kit should be positioned within 3 feet of the E4F or E6F actuator.
Programming code 3400 will need to be used to turn off the terminating resistor in the E4F or E6F actuator
controller. In this system the UBEC1 controllers will be secondary controllers and neither will be able to
override the other.
98311090 (Rev-C)
Elkhart Brass Mfg. Co., Inc. 1302 W. Beardsley Avenue • Elkhart, Indiana 46514 • 1-574-295-8330 • 1-800-346-0250
www.elkhartbrass.com
UICS2
Two UICS2 controllers can be used to control one E1F & E2F actuated valve. One controller would be the
primary and the other controller would need to be programmed as a secondary. We have part numbers set up
for primary controllers that include harness length options for connection to the E1F & E2F actuators. We have
part numbers set up for UICS2 controllers that include secondary harness length options for CAN connection
to the primary controller. The primary controller would override all secondary controllers.
The UICS2 CAF controller cannot be used to control an E4F or E6F actuated valve.
Instructions for Installation, Wiring, and Programming for the above scenarios can be found in the Unibody
Manual 98311000. The manual can be found on our website www.elkhartbrass.com
UBEC1C
Two UBEC1C controllers can be used to control one E3F or E5F actuated valve. The E3F or E5F actuator
controller will be the primary and the UBEC1C’s will be secondary’s. Our CAN connector kit p/n 37221000
would be required to interconnect the UBEC1Cs and the E3F or E5F actuated valve. The CAN wiring between
components would be supplied by the builder and will need to run from one UBEC1C to the CAN connector kit
then on to the other UBEC1C. The can lines from the valve will be connected to the CAN connector kit. The
CAN connector kit should be located within 3 feet of the valve actuator. Programming code 340 will need to be
used to turn off the terminating resistor in the E3F or E5F actuator controller. In this system the UBEC1C
controllers will be secondary controllers and neither will override the other.
The UBEC1C can also be used as a secondary controller connected to a primary UBEC1, UBEC2, or UBEC3
controller. The UBEC1C would be wired to the CAN terminals on the UBEC1, UBEC2, or UBEC3 primary
controller (wire supplied by builder) and would operate all valve functions and display valve position but when
used with a UBEC2 or UBEC3 controller will not display pressure or flow readout.
UBEC1S
Multiple UBEC1S controllers can be used with the E3F & E5F actuators. The builder would be responsible for
providing sealed connections of the leads for like valve functions from each controller into a single lead going
to the E3F or E5F actuators. In this set up the UBEC1S controllers would all be secondary controllers and
neither would be able to override the other.
The UBEC1S can not be used as a secondary with any other type of UBEC controller.
Instructions for Installation, Wiring, and Programming for the UBEC1C & UBEC1S can be found in the