SPECIFICATIONS
G
ENERAL
Self-contained, double wall hung electric refrigerated, water
cooler. Vandal-resistant unit for use in high demand locations
where vandalism may occur. Rated for indoor or outdoor use.
Stainless steel construction provides vandal-resistant
enclosure. Optional perforated stainless steel louver screen-
ing prevents objects from being inserted into cooler.
Flow regulators provide constant stream from 20 to 150 psi
water pressure. Heavy duty push button control is vandal-
resistant.
ADA COMPLIANT
T
hese Water Coolers comply with the requirements of A.D.A.
(
Americans with Disabilities Act) when properly installed. Also
meets the guidelines for children’s environments providing
the floor to orifice height is 30" or less and proper clear floor
space is provided for parallel approach. (Based on
Architectural and Transportation Barriers Compliance Board
final ruling.) Check Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined
by the Safe Drinking Water Act. Elkay Water Coolers are man-
ufactured with a waterway system utilizing copper compo-
nents and completely lead-free materials. These waterways
have no lead because all lead materials, such as leaded
brass, have been removed. All joints are brazed using silver
solder only. No lead solder is permitted. A strainer with an
easily cleanable screen is provided to allow trapping and con-
venient removal of waterborne particulate of 140 microns and
larger prior to their entry into the water cooler.
COOLING SYSTEM
Motor Compressor:Hermetically sealed, reciprocating type,
120 Volt/60 Hz, single phase or 220-240 Volt/50 Hz or 60 Hz,
two phase. Sealed-in lifetime oil supply. Equipped with elec-
tric cord and three prong molded rubber plug.
Condenser:Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit:Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. require-
ments for self extinguishing material.
CAPACITIES CHART
**Based on 80°F (27°C) inlet water temperature.
Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
Refrigerant Control:Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
operation.
Temperature Control:Enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude
requirements. Easily accessible.
CONSTRUCTION
Frame:Galvanized structural steel chassis supports fountain
top and cabinet panels.
Fountain Top:Series 300 one piece stainless steel top,
polished to a uniform Elkay bright luster finish. Basin has
embossed bubbler pad.
Vandal-Resistant Bubbler:Heavy duty, one piece construc-
tion. Keyed into position to prevent rotation. Meets UL
requirements and all sanitary codes.
Cabinet:Cabinet design allows for flush to wall mounting. No
recess space is required. Includes bottom cover plate
fastened with vandal-resistant screws.
Color Selection:Stainless steel furnished as standard.
ALSO AVAILABLE
MODEL VRCSCTLR8SC:Same as VRCTLR8SC model with
perforated stainless steel louvers screening prevents objects
from being inserted into coolers.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi (138 KPa) to 105 psi (724 KPa) supply line pressure.
If inlet pressure is above 105 psi (724 KPa), a pressure
regulator must be installed in the supply line. Any damage
caused by reason of connecting this product to supply line
pressures lower than 20 psi (138 KPa) or higher than 105 psi
(724 KPa) is not covered by the warranty.
STANDARDS
Model VRCTLR8SC
**GPH of 50°F
Drinking Water
Ship.
Room Temperature °F
FullGlassWt.
ModelVolt./Base70°F80°F90°FRatedLoadFillerFilterLouverLbs.
NumberHertzRate(21°C)(27°C)(32°C)WattsAmpsOptionOptionScreens(Kg.)
VRCTLR8SC
120V/
7.89.48.67.85755NoYesYes94
60Hz
220-
VRCTLR8S2JOC240V/6.57.97.26.55752.5NoYesYes94
50Hz
220-
VRCTLR8S3JOC240V/7.59.48.67.85752.5NoYesYes94
60Hz
VRCTLRDDSC–––––––
NoYesYes56
G
ENERAL
Self-contained, double wall hung electric refrigerated, water
cooler. Vandal-resistant unit for use in high demand locations
where vandalism may occur. Rated for indoor or outdoor use.
Stainless steel construction provides vandal-resistant
enclosure. Optional perforated stainless steel louver screening prevents objects from being inserted into cooler.
Flow regulators provide constant stream from 20 to 150 psi
water pressure. Heavy duty push button control is vandalresistant.
ADA COMPLIANT
T
hese Water Coolers comply with the requirements of A.D.A.
(
Americans with Disabilities Act) when properly installed. Also
meets the guidelines for children’s environments providing
the floor to orifice height is 30" or less and proper clear floor
space is provided for parallel approach. (Based on
Architectural and Transportation Barriers Compliance Board
final ruling.) Check Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined
by the Safe Drinking Water Act. Elkay Water Coolers are manufactured with a waterway system utilizing copper components and completely lead-free materials. These waterways
have no lead because all lead materials, such as leaded
brass, have been removed. All joints are brazed using silver
solder only. No lead solder is permitted. A strainer with an
easily cleanable screen is provided to allow trapping and convenient removal of waterborne particulate of 140 microns and
larger prior to their entry into the water cooler.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
120 Volt/60 Hz, single phase or 220-240 Volt/50 Hz or 60 Hz,
two phase. Sealed-in lifetime oil supply. Equipped with electric cord and three prong molded rubber plug.
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with EPS
foam which meets Underwriters Laboratories Inc. requirements for self extinguishing material.
CAPACITIES CHART
**Based on 80°F (27°C) inlet water temperature.
Rated watts shown are based on operational (run) time, in accordance with A.R.I.
Standard 1010 conditions. Specific app lications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
operation.
Temperature Control: Enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude
requirements. Easily accessible.
CONSTRUCTION
Frame: Galvanized structural steel chassis supports fountain
top and cabinet panels.
Fountain Top: Series 300 one piece stainless steel top,
polished to a uniform Elkay bright luster finish. Basin has
embossed bubbler pad.
Vandal-Resistant Bubbler: Heavy duty, one piece construc-
tion. Keyed into position to prevent rotation. Meets UL
requirements and all sanitary codes.
Cabinet: Cabinet design allows for flush to wall mounting. No
recess space is required. Includes bottom cover plate
fastened with vandal-resistant screws.
Color Selection: Stainless steel furnished as standard.
ALSO AVA ILABL E
MODEL VRCSCTLR8SC: Same as VRCTLR8SC model with
perforated stainless steel louvers screening prevents objects
from being inserted into coolers.
Elkay Pressure-Type Water Coolers are designed to operate
on 20 psi (138 KPa) to 105 psi (724 KPa) supply line pressure.
If inlet pressure is above 105 psi (724 KPa), a pressure
regulator must be installed in the supply line. Any damage
caused by reason of connecting this product to supply line
pressures lower than 20 psi (138 KPa) or higher than 105 psi
(724 KPa) is not covered by the warranty.
STANDARDS
Model VRCTLR8SC
**GPH of 50°F
Drinking Water
Ship.
Room Temperature °F
Full GlassWt.
Model Volt./ Base 70°F 80°F90°FRatedLoadFiller FilterLouverLbs.
Number Hertz Rate (21°C)(27°C)(32°C) Watts AmpsOptionOption Screens (Kg.)
VRCTLR8SC
120V/
7.8 9.4 8.6 7.8 5755 NoYesYes 94
60Hz
220-
VRCTLR8S2JOC 240V/ 6.5 7.9 7.2 6.5 575 2.5 No Yes Yes 94
50Hz
220-
VRCTLR8S3JOC 240V/ 7.5 9.4 8.6 7.8 575 2.5 No Yes Yes 94
60Hz
VRCTLRDDSC – – – – – ––
No Yes Yes 56
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2 Station Wall-Mount Water Cooler
Vandal-Resistant, Barrier Free Access
Models VRCTLR8SC
2222 Camden Court
Oak Brook, IL 60523
Protected by Elkay’s 5 Year Limited Warranty on the refrigeration system of the unit.
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
Printed in U.S.A.
©2011 Elkay
(Rev. 4/11) 12-58A
2 Station Wall-Mount Water Cooler
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY
1
/4" O.D. TUBE
W
ATER INLET
T
O COOLER
BUILDING WATER
INLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
3
/8" O.D. TUBE CONNECT
C
OLD WATER SUPPLY
1
/4" O.D. TUBE
W
ATER INLET
T
O COOLER
BUILDING WATER
INLET
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDREN'S ADA COOLER
LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
3" (76mm) MAXIMUM OUT FROM WALL.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN.
C = 1-1/4" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX.
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 5/16" BOLT HOLES FOR FASTENING UNIT TO WALL.
*ADA REQUIREMENT
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDREN'S ADA COOLER
LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
3" (76mm) MAXIMUM OUT FROM WALL.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN.
C = 1-1/4" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX.
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 5/16" BOLT HOLES FOR FASTENING UNIT TO WALL.
*ADA REQUIREMENT
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH
T
UBE IS SECURED
IN POSITION
P
USH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
OPERATION OF QUICK CONNECT FITTINGS
S
IMPLY PUSH IN
TUBE TO ATTACH
T
UBE IS SECURED
IN POSITION
P
USH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
13 7/8"
352mm
18 3/4"
476mm
37 1/2"
952mm
6 1/2"
166mm
20 3/8"
518mm
26 11/16"
677mm
31 11/16"
804mm
3 1/2"
89mm
4 1/2"
114mm
5"
127mm
10"
254mm
5
3/4"
146mm
5
3/4"
146mm
1 3/8"
35mm
1 3/8"
35mm
18 1/16"
4
59mm
5 3/4"
146mm
5 3/4"
146mm
1 3/8"
35mm
1 3/8"
35mm
5"
128mm
2 7/16"
63mm
1 1/2"
38mm
18 5/8"
474mm
2 5/8"
67mm
8"
203mm
4 3/4"
121mm
12 5/16"
312mm
27"
686mm
31 7/8"
810mm
32 15/16"
837mm
39 1/2"
1003mm
H
ANGER BRACKET
FIJADOR DE SUSPENSION
SUPPORT DE SUSPENSION
ORIFICE
HEIGHT
ALTURA DEL
ORIFICIO
HAUTEUR DE
L'ORIFICE
ORIFICE
HEIGHT
ALTURA DEL
ORIFICIO
HAUTEUR DE
L'ORIFICE
RIM HEIGHT
ALTURA DEL
ORIFICIO
HAUTEUR DE
L 'ORIFICE
*
B
D
E
E
F
F
A
C
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
5/16" (8mm) DIA. (10 HOLES)
8mm (10 AGUJEROS)
8mm (10 TROUS)
6 3/4"
173mm
13 7/8"
352mm
18 3/4"
476mm
37 1/2"
952mm
6 1/2"
166mm
20 3/8"
518mm
26 11/16"
677mm
31 11/16"
804mm
3 1/2"
89mm
4 1/2"
114mm
5"
127mm
10"
254mm
5
3/4"
146mm
5
3/4"
146mm
1 3/8"
35mm
1 3/8"
35mm
18 1/16"
4
59mm
5 3/4"
146mm
5 3/4"
146mm
1 3/8"
35mm
1 3/8"
35mm
5"
128mm
2 7/16"
63mm
1 1/2"
38mm
18 5/8"
474mm
2 5/8"
67mm
8"
203mm
4 3/4"
121mm
12 5/16"
312mm
27"
686mm
31 7/8"
810mm
32 15/16"
837m m
39 1/2"
1003mm
H
ANGER BRACKET
FIJADOR DE SUSPENSION
SUPPORT DE SUSPENSION
ORIFICE
HEIGHT
ALTURA DEL
ORIFICIO
HAUTEUR DE
L'ORIFIC E
ORIFICE
HEIGHT
ALTURA DEL
ORIFICIO
HAUTEUR DE
L'ORIFICE
RIM HEIGHT
ALTURA DEL
ORIFICIO
HAUTEUR DE
L 'ORIFICE
*
B
D
E
E
F
F
A
C
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
5/16" (8mm) DIA. (10 HOLES)
8mm (10 AGUJEROS)
8mm (10 TROUS)
6 3/4"
173mm
Vandal-Resistant, Barrier Free Access
Models VRCTLR8SC
ROUGH-IN DIMENSIONS
MPORTANT!
I
NSTALLER PLEASE NOTE:
his water cooler has been designed and built to provide water to the user which
T
as not been altered by materials in the cooler waterways. The grounding of elec-
h
rical equipment such as telephone, computers, etc., to water lines is a common
t
rocedure. This grounding may be in the building but may also occur away from
p
he building. This grounding can cause electrical feedback into a water cooler
t
reating an electrolysis which creates a metallic taste or causes an increase in the
c
etal content of the water. This condition is avoidable by installing the cooler using
m
he proper materials as shown below.
t
his water cooler must be connected to the water supply using a dielectric
T
oupling. The cooler is furnished with a non-metallic strainer which meets this
c
equirement. The drain trap which is provided by the installer should also be plastic
r
o completely isolate the cooler from the building plumbing system.
t
Minimum 40 psi supply line pressure required in special circumstances when both
sides of bilevel are in use simultaneously to ensure adequate stream height. Does
not apply to non-refrigerated units.
I
OTICE
N
Elkay
12-58A (Rev. 4/11)
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.
©2011 Elkay